Series 2 3 4 Class 2 Class 3 Class 4 OUT port size Symbol 01 02 Port size 1/8 (6A) Stations 2 3 4 5 n Uside D side 1/4 (8A) Material All IN ports are 3/8.
E Round pressure gauge G Panel mount (with set nut) P JIS Symbol 0.02 to 0.2MPa setting 1 N Non-relieving type R Flow direction: Right Left Display units for product name plate and pressure gauge: PSI, F.
800 N Holding force 320 N 0.43 0.68 1.
Holding force 25 320 N 32 500 N 40 800 N MLGC Shock absorber can absorb small to large impacts without adjustments due to self compensation. CNG MNB Brake construction is designed not to allow loads on guide.
R ports Stations Note 4) K 01 1 station N R S T Note 5) Note 6) The maximum number of stations differs depending on the electrical entry.
to Order SS5YJ7--40-05 -01 P port Rc(PT)1/4 Stations 01 Rc(PT)1/8 A, B port side 2 stations 02 : : 20 stations 20 R port Rc(PT)1/4 A, B port Rc(PT)1/8 Note) For more than 10 stations, supply air to both sides of "P" port and exhaust air from both sides of "R" port.
1 Valve 2, 3 diagnostics 01 2 Valve 4, 5 diagnostics 01 3 Valve 6, 7 diagnostics 01 4 Valve 8, 9 diagnostics 01 5 Valve 10, 11 diagnostics 01 6 Valve 12, 13 diagnostics 01 7 Valve 14, 15 diagnostics 01 Valve diagnostics 2 . 5-5 Valve diagnostics 2 Bit 0 Valve 16, 17 diagnostics 01 1 Valve 18, 19 diagnostics 01 2 Valve 20, 21 diagnostics 01 3 Valve 22, 23 diagnostics 01 4 Valve 24, 25
Description IR1000 IR1010 IR1020 IR2000 IR2010 IR2020/2120 IR3000 IR3010 IR3020/3120 P362030-201 Bracket P36201023 P36202028 Pressure gauge234 G33-2-01 G33-10-01 G43-2-01 G43-10-01 G43-2-01 G43-4-01 G43-10-01 G33-4-01 G43-4-01 1 A bracket and two mounting screws (M5 x 35) To mount the bracket, remove two body screws (M5 x 30) on the name plate on the opposite side and replace the attached
(Example) 7 stations of VXA31, Individual port Rc Blanking plate Common port 1 8 Plug Individual port (Base P/N) VXA311-07 1 pc (Valve P/N) VXA3115-00 6 pcs (Blanking plate P/N) VX011-0041 pc The standard arrangement of manifolds should be placed on an individual port on this side, each solenoid valve from the left side and a blank plate in the right side.
(AL06, AL07, AL08, and AL09 will not be generated) HRS Series 5.20Alarm customizing function 5-47 HRX-OM-S004 Chapter 5 Display and setting of various functions Table 5.20-3 Alarm setting and customizing (2/4) Alarm operations Alarm threshold and others Code Alarm name OFF A.RU P.RU A.ST Display Default setting Settable N N P Display range Refrigerant circuit pressure (low AL17 pressure
(N) and (P+) (N-)) of the main circuit converter is displayed. 0 to 900 V 19 Station No.
(N) and (P+) (N-)) of the main circuit converter is displayed. 0 to 900 V 19 Station No.
(mm) Weight (g) P Part No.
IZN10 IZN10 IZN10 IZN10 01 01 01 01 P P P P 06 06 06 06 Z Z Z Z B1 B1 B1 B1 IZN10 AC 01 02 11 Rc1/8 NPN P PNP 06 6 07 6.351/4) 16 6 ( 17 6.351/4() (3m) Z (10m) N IZN10-NT L DIN IZN10A002 IZN10B1 L B2 B3 DIN 01 06 ES 2 01 ES 17mm 2 2 02 3 3 11 Rc1/8 4 4 /IZS30 /IZS30 /IZS30 /IZS30-M2 M2 M2 M2 06 6: 07 6.351/4: 16 6 :( 17 6.35(1/4):() IZN10-CP(3m) IZN10-CPZ(10m) IZN10A003 NPN
Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% 1 Electric spec.
P Polyolefin P White, Black Red, Blue Yellow, Green 20 P P 100 TPS P P P Soft Polyolefin P P 1ft = 0.3048 1in = 25.4mm 3 Series KP Clean One-Touch Fittings Recommended Applicable Tubing Polyolefin: Series TPH Soft polyolefin: Series TPS Tubing material 4, 6, 8, 10, 12 Tubing O.D.
P Polyolefin P White, Black Red, Blue Yellow, Green 20 P P 100 TPS P P P Soft Polyolefin P P 1ft = 0.3048 1in = 25.4mm 3 Series KP Clean One-Touch Fittings Recommended Applicable Tubing Polyolefin: Series TPH Soft polyolefin: Series TPS Tubing material 4, 6, 8, 10, 12 Tubing O.D.
Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: R 1/8, Option 1: -, Option 2: -, Option 3: -
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: 01 (R 1/8)