KNH-R02-100 KNH-R02-150 KNH-R02-200 1 1.5 2 R1/4 14 52 46 D H1 A L1 Reference dimensions after R thread installation Low noise nozzle with male thread: KNS (mm) thread L1 A Width across flats H1 D Connection Nozzle size Part no.
Right Left Right Left 112 (3.7) Vacuum (V) port (M5) Note 5) 21 10 Dimensions 1 2 3 4 5 6 7 8 (mm) n L1 L2 K J 5 6 Note 2) The above dimensions are for ZQ1000M2 .
Series CS2 XC86B, XC86C H A L1 H1 Symbol Applicable knuckle joint part number Y type double knuckle Y-12A Y-14A Y-16A H1 L1 A H I type single knuckle I-12A I-14A I-16A Bore size (mm) 125 140 160 156.5 161.5 170.5 100 105 110 3.5 3.5 3.5 50 50 56 110 110 120 Series CS2 XC86D, XC86E H A L1 H2 H1 Symbol Applicable rod end nut Applicable knuckle joint part number Y type double knuckle Y-12A
U side 7 6 5 4 3 2 D side Stations 1 Cable 6 to 12 G1/2 G1/2 (44) R3 R4 T E D R1, R6 R5 R2 F F n x 1/8,1/4
VDW 0 1 C 1 1 2 Socket Series Lead wire length Cover 1 2 3 10 20, 200 30, 300 300 mm 600 mm Nil L1 Note) Note) Type L1 is optional. Coil type C F W When piping to an N.O. port, be sure to perform piping work while securing the socket by using wrench or other tool. Refer to back page 261 for other precautions related to piping.
Customer's cable connection Terminal block for signal L1 L2 L3 1,2: Operation 3,4: Failure 5,6: Remote control 1 3 2 4 5 6 Terminal connecting screw: M5 Crimped terminal width: 9.5mm or less Applicable electric wire: 3.5mm2 or more Customer's cable connection Applicable electric wire: 1.25 to 1.5mm2 Terminal block for power supply L1,L2,L3: Power supply PE: Ground L2 L3 PE L1 Customer's cable
D2 L1 L2 L3 P Q1 Q2 A MB MA tube O.D.
WB x L1 > MD Third tentative determination of bore size using the graph of maximum speed (U) and load weight (W). Determination of rotational moment WB x L1 MD (See page 64 for body non-rotating accuracy and maximum allowable moment.) ( ) Bore size determination Bore size is the largest of 3 tentative determinations.
L4 Weight (g) A L3 L1 L2 D1 D2 D3 Part No.
Allowable Moment (Nm) Allowable dynamic moment Allowable static moment Pitching Rolling Yawing LXF Model Load movement direction 4 3 4 a = 1000 2000 a Mep a = 2000 L1 (mm) Pitching Rolling Yawing a = 3000 m : Transfer load (kg) L : Overhang to work piece center of gravity (mm) a : Work piece acceleration (mm/sec) Me: Dynamic moment 1000 m L1 3 0 1 2 Transfer load m (kg) a = 1000 300 L2 (mm
VV3Q11 (L5) (L4) (L3) (8.5) 88 L2 48.7 L1 Plug ass'y VVQ100-12A2 3 1 (35) (45) 33 (5.5) 23.5 12.3 E 3 2 R11(Min. bending inner radius) 21.5 Manual override (29.3) 104 D side U side Stations 1 2 3 4 5 n 2-M50.8(E port) 2-M50.8(P port) 42.9 A A (8.5) 20 5 15 (7.5) 5 (A port) n-M50.8 15 P=10 Dimensions n: Stations(Max.18 stations) Equation : L1=10n+32 L2=10n+43 n L 2 52 63 83 112.5 123 3 62
196.5 300 369 L1 77 115.5 154 231 346.5 269.5 192.5 308 385 VV2CW3 L2 89 127.5 166 243 358.5 281.5 204.5 320 397 L3 101 139.5 178 255 370.5 293.5 216.5 332 409 L1 83 124.5 166 249 373.5 290.5 207.5 332 415 VV2CW4 L2 95 136.5 178 261 385.5 302.5 219.5 344 427 L3 107 148.5 190 273 397.5 314.5 231.5 356 439 Manifold composition 2stns. x 1 3stns. x 1 2stns. x 2 3stns. x 2 3stns. x 3 2stns. x
Body (Material: SCS13) Refer to the page 22 for the maintenance parts. 5 Series XMC, XYC Dimensions XMC/Angle type C D L2 (KF flange) Fd Fc Fn C (Fc) L1 (K flange) (CF flange) J H B G A A L2 (mm) Model A 110 120 171 183 209 250 B 38 48 66 79 100 117 C 1 1 2 2 3 3 D 30 40 55 75 87 114 Fn 95 110 Fd 34 70 114 Fc 17 26 41 52 70 83 G 40 39 63 68 69 96 H J P.C.D L1 6-4.4 6-6.6 8-8.4 XMC
1 Left Right OUT 1 OUT 5 Stations L1 L2 L3 1 106 2 144 38 3 182 38 76 4 220 76 114 5 258 114 152 6 296 152 190 63 (Max. 65) 34 DC () OUT 6 5 17 DC (+) 39 (With HW, SW) M4 x 8 Detection port 19 Rc, NPT, G 1/8 Terminal block box wiring diagram For the bracket mounting position, refer to page 877. (21) Seal conduit entry With DIN rail L1 60 3 38 L2 38 5 Terminal block box LED level meter
(A conversion cable is not required for the JXC-W2.) 2 Step Motor Controller JXCE1/91/P1/D1/L1 Series How to Order Actuator + Controller R1 CD17T LEFS16B-100 Controller Nil Without controller Cm1mm With controller Actuator type Refer to How to Order in the actuator catalog. For compatible actuators, refer to the table below.
(mm) Body size H Width across flats Min. bore size Model T Connection port size Weight g Effective area mm2 L2 L1 KKA3P-01F-1 Rc 1/8 23.2 9.6 14 -02F-1 1/8 T Rc 1/4 6.0 22.6 16.0 30.3 20.2 17 -03F-1 Rc 3/8 32.0 26.2 19 KKA4P-02F-1 Rc 1/4 29.7 20.0 17 -03F-1 1/4 Rc 3/8 8.0 40.2 18.9 34.0 25.8 19 -04F-1 Rc 1/2 39.4 46.1 24 L2 H KKA6P-03F-1 Rc 3/8 30.9 34.3 22 L1 -04F-1 1/2 Rc 1/2 11.0 76.0
Connecting thread T L2 H D1 D2 L1 L2 L3 L4 (1) A (2) Max.
Applicable bore size (mm) A A1 E1 L1 MM R1 U1 ND NX NZ L Included pin part no.
A A1 E1 L1 MM R1 U1 NX NDH10 U1 L1 A A1 L1 U1 A1 I-G02 I-G03 I-G04 I-G05 I-G08 I-G10 16 20 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.084 0 0.2 0.4 0.2 0.4 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 34 41 42 56 71 79 8.5 25 30 30 40 50 55 M8 x 1.25 10.3 11.5 8 10 10 14 18 22 8 10 18 22 28 32 M10 x 1.25 10.5 12.8 14 A M14 x 1.5 22 14 12 14 (mm) M18 x 1.5 28 18 16 20 Applicable bore size (mm) Included
MM L RR1 RR1 E1 E1 A L1 U1 A1 NX A1 L1 U1 NZ NX A Part no. Applicable bore size (mm) E1 Part no. Applicable bore size (mm) E1 Applicable pin no.