CD d1 d2 E1 EW FL L l1 l2 MR R1 TG1 32 C5032 10 30 6.6 45 260.2 0.6 22 12 5 5.5 9.5 6.5 32.5 40 C5040 12 35 6.6 51 280.2 0.6 25 15 5 5.5 12 6.5 38 50 C5050 12 40 9 64 320.2 0.6 27 15 5 6.5 12 8.5 46.5 63 C5063 16 45 9 74 400.2 0.6 32 20 5 6.5 16 8.5 56.5 80 C5080 16 45 11 94 500.2 0.6 36 20 5 10 16 11 72 100 C5100 20 55 11 113 600.2 0.6 41 25 5 10 20 12 89 CDH9 * Supplied with 4 mounting
Bore size 12 to 25 Without auto switch, With auto switch CD hole H10 0.4 0.2 CX CL 4 x CN R M CT A + Stroke CW CZ Applicable Cylinders/Double Clevis Pivot Bracket Part No. (mm) Hexagon socket A CN part no.
Shaft Pattern Sequencing I -XA1 to XA24 Applicable shaft type: W (Standard) Connection port location CRB2 63 90 S E XA1A2C1C30 Without auto switch C RB1BW P CRBU2 With auto switch CRB1 63 90 S T79L XA1A2C1C30 CD RB1BW P E MSU With solenoid valve (Refer to page 11-4-6.)
With rod boot Wid h across flas KA t t ~ "CD hole HI O 4, I ~' Shaft d9 ; . : ' ! ~ "~ R f-:: h r~~ h \ I 1I : tIlw ';1 ' t:rI D I-=' ~ ~ ::;: P , ~ \ -.-J ~ 0!.. A F N N CT I---"-: Kl.
Shaft Pattern Sequencing I -XA1 to XA24 Applicable shaft type: W (Standard) Connection port location CRB2 63 90 S E XA1A2C1C30 Without auto switch C RB1BW P CRBU2 With auto switch CRB1 63 90 S T79L XA1A2C1C30 CD RB1BW P E MSU With solenoid valve (Refer to page 11-4-6.)
Shaft Pattern Sequencing I -XA1 to XA24 Applicable shaft type: W (Standard) Connection port location CRB2 63 90 S E XA1A2C1C30 Without auto switch C RB1BW P CRBU2 With auto switch CRB1 63 90 S T79L XA1A2C1C30 CD RB1BW P E MSU With solenoid valve (Refer to page 11-4-6.)
hole H10 Shaft dg RR CU CW DCL + Stroke A + Stroke -X 20Data Foot style Rod side flange, Head side flange Double clevis style A Head side flange A Bore size (mm) LA LB LD LE LH LL LS LX LY LZ FG FL FV FX FZ A CD CL CU CW CX CZ RR 12 20 106.5 4.5 8 4.5 29.5 17 2 85 34 52 44 4.5 5.5 25 45 55 114 5 108 7 14 5 10 6 99.5 121 5.8 9.2 6.6 42 24 3.2 96.4 48 66.5 62 6.6 8 39 48 60 133 8 124 12 18
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com L CZ CT CT Y V U Conveyor lower limit position CD T R Stroke H B 2-P D QA FT A GA Rear pressure port Front pressure port QB 2-Plug WB GB E W (Width across corners I) (mm) Width across corners I 85 103 132 GA 16 24 24 H 128 144.5 171.5 FT 20 25 25 FX
Contact protection box internal circuit CD-P11 Brown lead wire Surge absorber Mounting Choke coil Warning Blue lead wire 1. Do not use the switch unless the equipment operates normally. CD-P12 Brown lead wire Zener diode Choke coil After installation, repair or reform, connect air and electricity and conduct appropriate function and leakage tests to confirm proper installation.
(Drill through) Note) Dd9 L l d m H B C CJ1 D Cotter pin 3 x 18l 4 x 25l 4 x 35l 0.040 0.076 0.050 0.093 0.065 0.117 NT-03 NT-04 NT-05 NT-08 NT-10 CD-M03 CD-M05 CD-M08 10 14 22 32 40 50, 63 80 100 32, 40 50, 63 80, 100 3 4 4 44 60 82 36 51 72 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 4 4.5 5 6 8 11 13 16 17 22 27 32 41 19.6 25.4 31.2 37.0 47.3 16.5 21 26 31 39 CJP CJ2 Note) When
CD Type C snap ring CJ1 CJP Rod end nut (Refer to accessory bracket dimensions.)
AS ASP ASN AQ ASV Dimensions AK Universal type Weight (g) T H1 H2 D1 D2 D3 L1 L2 L3 L4 L5 A M1 Max. Min. Max. Min.
(mm) H2 Q P L W H1 Model TMA-06 TMA-08 TMA-10 TMA-12 28 21.7 172.5 31.8 25.4 151.2 35 28.1 167.3 37 19 151 17.9 20.3 24.3 26.7 18.6 18.6 22 22 11.4 12.6 15 16.2 6 12 10 8 15-6-32 1 Related Products: Tube Cutter Series TK Tube Cutter: TK-2 Possible to cut a tube up to 18 mm.
Tapped on Body Side MXU MXP6, MXPJ6 MXP8, 10, 12, 16 l D D H1 H1 MXS Body MXQ Max. tightening torque N m Max. screw-in depth l (mm) Model Bolt D D H2 H2 MXF MXP8 MXP10 MXP12 MXP16 1.2 1.2 2.1 4.4 M3 x 0.5 M3 x 0.5 M4 x 0.7 M5 x 0.8 4 5 6 8 MXW Pinhole diameter Pinhole depth Model H1mm H2mm D 2.5 2.5 3 3 3 4H9 0 +0.030 MXPJ6 MXP6 MXP8 MXP10 MXP12 MXP16 MXJ 2.5 2 1.
(mm) Mounting screw P L1 H2 D W1 L2 H1 W2 W3 Model (Nominal x Length) 6 4 TM-04 TM-06 TM-08 TM-10 TM-12 6 3.25 72.5 4.5 5.5 6 6.5 6.5 10 5 7.5 7.5 8 12 12 8 10 11 12 12 17 21 23 25 25 2.2 2.8 2.8 3.2 3.2 2 x 6 4.5 91.5 9.5 5.5 77.5 6 12.5 7.5 77.5 6 15 9 93 6.5 2.6 x 8 2.6 x 8 3 x 8 3 x 8 12 10 8 16.3 8.8 14.3 7.5 12 9.8 How to Use Caution 1.
LVM VCA High speed response Reduced dispersion VCB VCL Check Valve VCS Series VCHC40 VCW Using NSF-H1-certified grease on the guide ring (sliding part).
T2 L6 L4 A1 H1 L5 A3 T1 A2 Applicable tubing diameter d A1 A2 A3 D1 D2 H H1 L1 L2 L3 L4 L5 L6 M T T1 T2 Model number 6mm 1/4 1/4 8mm (5/16) 10mm 3/8 12mm 1/2 ASP330F-U01-06-X352 ASP330F-U01-07-X352 ASP430F-U02-07-X352 ASP430F-U02-08-X352 ASP530F-U03-10-X352 ASP530F-U03-11-X352 ASP630F-U04-12-X352 ASP630F-U04-13-X352 45.7 9.4 45.5 G 1/8 51.1 16.1 14 29.3 14 13.7 38.4 22.9 26.9 11.6 14.2 1/
Hysteresis mode: [H_1] Window comparator mode: [ H1] The snap shot function can be used. (Refer to page 64) Press the SET button to set. Move on to delay time setting. Delay time setting Press the UP or DOWN button to select the delay time. Delay time set range: 0.00 to 60.00 [s] Press the SET button to set.
AS ASP ASN AQ ASV Dimensions AK Universal type Weight (g) T H1 H2 D1 D2 D3 L1 L2 L3 L4 L5 A M1 Max. Min. Max. Min.
With End Lock 16 to 40 MY1H E (Right end) L1 Long hole for stroke adjustment (Adjustment range : to TL mm) W1 W2 W3 H1 H2 MY1H F (Left end) MY1H W (Both ends) L1 Long hole for stroke adjustment (Adjustment range: to TL mm) (mm) H1 H2 L1 TL W1 W2 W3 Model MY1H16 39.2 33 0.5 5.6 18 16 10.4 MY1H20 45.7 39.5 3 6 18 16 10.4 MY1H25 53.5 46 3 11.5 29.3 27.3 17.7 MY1H32 67 56 6.5 12 29.3 27.3 17.7