Applicable Stroke Table Compatible Controllers KStandard/K Produced upon receipt of order Stroke Model LEL25 100 200 300 400 500 600 700 800 900 1000 Step data input type Programless type K K K K K K K K K K The actuator and controller are sold as a package. Type (Controller Page 13) Confirm that the combination of the controller and the actuator is correct.
This allows for viable connections to take place without necessarily specifying whether the manifold station is double, single, or mixed wiring. 19 20 19 20 19 20 19 20 19 20 19 20 19 20 19 20 COM. Station 1 Double wiring Station 2 Single wiring Station 3 Double wiring Station 4 Single wiring Connector Top entry Connector entry direction can be changed with a single push.
B1 I Eh8 Eh8 D NA MM 1.5 Width across flats KA -0.1 -0.2 CX Effective thread length FL AL NA K A U F N N ZZ + Stroke Z + Stroke S + Stroke L H RR (mm) A AL F FL G H H1 I K D B1 CX L KA CD E MM N Bore (mm) 0 -0.033 0 -0.033 0 -0.033 0 -0.039 20 M8 x 1.25 20 18 15.5 13 8 13 10 9 10.5 10 20 41 5 33.5 5 30 6 25 M10 x 1.25 26 22 19.5 13 10 17 10 9 10.5 10 20 45 6 37.5 5.5 30 8 32 M10 x 1.25 26
B1 I Eh8 Eh8 D NA MM 1.5 Width across flats KA -0.1 -0.2 CX Effective thread length FL AL NA K A U F N N ZZ + Stroke Z + Stroke S + Stroke L H RR (mm) A AL F FL G H H1 I K D B1 CX L KA CD E MM N Bore (mm) 0 -0.033 0 -0.033 0 -0.033 0 -0.039 20 M8 x 1.25 20 18 15.5 13 8 13 10 9 10.5 10 20 41 5 33.5 5 30 6 25 M10 x 1.25 26 22 19.5 13 10 17 10 9 10.5 10 20 45 6 37.5 5.5 30 8 32 M10 x 1.25 26
B1 I Eh8 Eh8 D NA MM 1.5 Width across flats KA -0.1 -0.2 CX Effective thread length FL AL NA K A U F N N ZZ + Stroke Z + Stroke S + Stroke L H RR (mm) A AL F FL G H H1 I K D B1 CX L KA CD E MM N Bore (mm) 0 -0.033 0 -0.033 0 -0.033 0 -0.039 20 M8 x 1.25 20 18 15.5 13 8 13 10 9 10.5 10 20 41 5 33.5 5 30 6 25 M10 x 1.25 26 22 19.5 13 10 17 10 9 10.5 10 20 45 6 37.5 5.5 30 8 32 M10 x 1.25 26
(Standard: 80 mm-pitch) Maintenance detection level selection switch KJH04-M5-X34 30 20 Position Detection Switch Flow Sensor Pressure Control Pressure Sensor Balance adjustment trimmer 14 19 20 16 Note) The maximum bar length is 1260 mm. The air purge nozzles are arranged at an 80 mm-pitch.
2 stations 20 stations Note 1) Order DIN rail separately.
Analog 4 to 20 mA * When using this switch in combination with an LFE0, select output specification J.
surfaces, same surface) 1 20 D-Y7BA n 20 + 45 (n 2) 2 (n = 2, 4, 6, 8)*1 2 (Different surfaces, same surface) 1 15 D-P3DWA n (Different surfaces, same surface) 15 + 50 (n 2) 2 (n = 2, 4, 6, 8)*1 2 (Different surfaces, same surface) 1 15 D-P4DW n 15 + 65 (n 2) 2 (n = 2, 4, 6, 8)*1 *1 When n is an odd number, an even number that is one larger than the odd number is to be used for the calculation
B 7.5 9.5 8.5 14 B 10.5 12.5 11.5 17 B 7 9 8 13.5 20 25 32 40 Note) When setting an auto switch, be sure to check its operation before adjusting.
32 32 25 25 0.1 0.1 20 20 15 15 10 10 0.01 0.01 0 0 20 40 100 60 80 20 40 100 60 80 Overhang L (mm) Overhang L (mm) CXSJM CXSJL Graph V = over 400 mm/s; up to 50 mm stroke 13 CXSJM CXSJL Graph V = up to 400 mm/s; up to 50 mm stroke 12 1 1 Weight m (kg) Weight m (kg) 32 32 0.1 0.1 25 25 20 20 15 15 10 10 0.01 0 20 40 100 60 80 0.01 0 20 40 100 60 80 Overhang L (mm) Overhang L (mm) 5 Compact
T J K Z J CRB1 K K MSU CRJ XA38 XA39 XA40 XA41 XA45 XA46 K, T K CRA1 K K J J K J K K CRQ2 Y Y MSQ K, T K, T S K K J J MSZ X, Z X, Z T J, Z CRQ2X MSQX Z J MRQ J Reversed shaft, Change of double shaft length (With four chamfers, without keyway) Reversed shaft, Change of shaft length (With four chamfers) Reversed shaft, Change of shaft length (With keyway) X Combinations of
R O D B O R E S I Z E 7/16-20 7/16-20 7/16-20 3/4-16 3/4-16 3/4-16 1-14 1-14 1 1/4-12 1 1/2-12 1 7/8-12 5/8 5/8 5/8 1 1 1 1-3/8 1-3/8 1-3/4 2 2-1/2 S TA N D A R D S T R O K E 150 1.5 200 2 250 2.5 325 3.25 400 4 500 5 600 6 800 8 1000 10 1200 12 1400 14 E 1 G 1 3/8 H 1 3/4 J 2 K 2 1/2 L 3 M 3 1/2 Z Please consult P/A Customer Service for larger sizes.
R O D B O R E S I Z E 7/16-20 7/16-20 7/16-20 3/4-16 3/4-16 3/4-16 1-14 1-14 1 1/4-12 1 1/2-12 1 7/8-12 5/8 5/8 5/8 1 1 1 1-3/8 1-3/8 1-3/4 2 2-1/2 S TA N D A R D S T R O K E 150 1.5 200 2 250 2.5 325 3.25 400 4 500 5 600 6 800 8 1000 10 1200 12 1400 14 E 1 G 1 3/8 H 1 3/4 J 2 K 2 1/2 L 3 M 3 1/2 Z Please consult SMC Customer Service for larger sizes.
Examples of Internal Circuit and Wiring 1 to 5 V / 4 to 20 mA output type With temperature sensor 1 to 5 V output type PF3W5--1/2 PF3W5--1T Analogue output 1 to 5 V Analogue output 1 to 5 V Output impedance: 1 k Output impedance: 1 k Analogue output 4 to 20 mA Maximum load impedance Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 -22No.PF-OMN0010-J Flow Measurement Measurement
Holes vns 20/30/40/50 Cornbination with a ,noduta. sayle FBL :;t.ti:l Combination with a modular style AC20 Ac:t0 VHS2O VHS3O VHS4O VHS5O An nterface pad is required attached 1o a modular FRL.
15.5 30.15 VDW2 M5, 1/8 4 33 14 39 20 17 36.2 2 x J thread depth K VCH VDW VDW Body material Stainless Steel SX10 2 x 3.4 Mounting hole W Y Grommet VQ LVM X U D 300 Q F Full wave rectifier (AC type) [mm] C R E G Mounting method Model Port size P A B B1 C D E F J K M VDW1 M5 12 20 10 42.4 15 6 11 M2.5 4 11 VDW2 M5, 1/8 15 22 11 51.7 20 8 13.5 M3 5 15 B B1 2 x P Port size A Mounting bracket