COMPACT DUAL/BASIC CHILLER FOR LASER, HRS090 AND LARGER CAPACITIES, O88, 114.00000 lb
Packaging Materials Set, HRS090 AND LARGER CAPACITIES, O88, 83.00000 lb
Thermo Chiller, HRS090 AND LARGER CAPACITIES, O88, 134.00000 lb
Thermo Chiller, HRS090 AND LARGER CAPACITIES, O88, 134.00000 lb
1 NPT Conversion Fitting, HRS090 AND LARGER CAPACITIES, O88, 220.46000 lb
Thermo Chiller, HRS090 AND LARGER CAPACITIES, O88, 140.00000 lb
Caster, HRS090 AND LARGER CAPACITIES, O88, 580.00000 lb
Note 1) Every 30,000 hours for the HRS090 to 200 and the HRSH series
The default setting for alarm code “AL08” is stop operation for the HRS090 to 200.
The HRS090 is a compact chiller with large cooling capacity. A 9.0kW air cooled or 10.5kW water cooled refrigeration circuit can be selected. The chiller package also contains the coolant circuit, including pump, tank, heat exchanger, and sensor monitored flow path. Set temperatures are PID controlled, while the system is monitored for 41 alarms.
The HRS090 is a compact chiller with large cooling capacity. A 9.0kW air cooled or 10.5kW water cooled refrigeration circuit can be selected. The chiller package also contains the coolant circuit, including pump, tank, heat exchanger, and sensor monitored flow path. Set temperatures are PID controlled, while the system is monitored for 41 alarms.
The HRS090 is a compact chiller with large cooling capacity. A 9.0kW air cooled or 10.5kW water cooled refrigeration circuit can be selected. The chiller package also contains the coolant circuit, including pump, tank, heat exchanger, and sensor monitored flow path. Set temperatures are PID controlled, while the system is monitored for 41 alarms.
Cooling Capacity: 250 (25kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: M (Applicable to DI Water Piping)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: M (Applicable to DI Water Piping), High Pressure Pump: T1 (Inverter Pump Mounted)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T1 (Inverter Pump Mounted)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T2 (High Pressure Inverter Pump Mounted)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T1 (Inverter Pump Mounted), Feet: None, Flow Sensor: Z1 (without Either a Flow Sensor or Retaining Clip)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T1 (Inverter Pump Mounted), Feet: Y (with Feet/Without Rack Mounting Brackets)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping), High Pressure Pump: T1 (Inverter Pump Mounted)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping), High Pressure Pump: T2 (High Pressure Inverter Pump Mounted)