Table 1 100 Total operation cycles (10,000) 50 40 30 20 10 100 200 300 400 500 700 1000 Stroke (mm) Table 2 10 Particle concentration (particles/m) Class M3.5 [Class100] 10 10 Class M2.5 [Class10] Inner cover holding screw tightening torque [Nm] 10 Tightening torque Model Screw size Class M1.5 [Class1] CYP15 0.3 M3 x 0.5 10 CYP32 2.45 M6 x 1 10 0.01 0.1 1 10 Plate Particle diameter (m) Note
Table 1 100 Total operation cycles (10,000) 50 40 30 20 10 100 200 300 400 500 700 1000 Stroke (mm) Table 2 10 Particle concentration (particles/m) Class M3.5 [Class100] 10 10 Class M2.5 [Class10] Inner cover holding screw tightening torque [Nm] 10 Tightening torque Model Screw size Class M1.5 [Class1] CYP15 0.3 M3 x 0.5 10 CYP32 2.45 M6 x 1 10 0.01 0.1 1 10 Plate Particle diameter (m) Note
A grease pack (10 g) is included. If an additional grease pack is needed, order with the following part number.
[MPa] Circulating fluid pressure [MPa] Usable flow rate range Usable flow rate range 0.5 0.5 50 HECR 50 0.43 0.45 Outlet Pump head [m] Pump head [m] Outlet 0.4 0.4 40 40 HEC 0.3 30 0.3 30 HEB 0.2 20 0.2 20 HED Return port 0.1 10 0.1 10 Return port 0 0 0 0 HEA 45 40 50 0 10 20 30 60 70 80 90 100 110 120 Circulating fluid flow rate [L/min] 45 0 20 10 40 30 50 60 70 80 90 100 110 120 130 Circulating
size (mm) 40 50 63 80 100 Stroke range up to 500 up to 600 up to 600 up to 750 up to 750 B B1 C A AL D E F G H H1 J K KA M MM N S S ZZ 156 169 180 214 225 ZZ 146 159 170 204 215 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10 10 10 14 14 15 17 17 21 21 51 58 58 71 72 8 11 11 13 16 M8 x 1.25 6 7 7 10 10 14 18 18 22 26 11 11 14
Transition wiring cable length (same cable length) m Power supply cable length: 3 m Transition wiring cable length (same cable length) m Power supply cable length: 10 m Bar length symbol 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 340 400 460 580 640 820 1120 1300 1600 1900 2320 2500 2.
Specifications LAT3-10 Stroke 10 mm, Resolution 30 m LAT3-20 Stroke 20 mm, Resolution 30 m Card Motor 8 options LAT3-30 Stroke 30 mm, Resolution 30 m (Refer to the table Product LAT3M-50 Stroke 50 mm, Resolution 5 m Number on the right) LAT3F-10 Stroke 10 mm, Resolution 1.25 m LAT3F-20 Stroke 20 mm, Resolution 1.25 m LAT3F-30 Stroke 30 mm, Resolution 1.25 m LAT3F-50 Stroke 50 mm, Resolution
Speed controller Silencer Tube x Length Speed controller Silencer SX3140-01 SX3120-C6 AS3001F-06 AN110-01 AS2051F-06 AN120-M5 T0604 x 1 m T0806 x 1 m AS3001F-08 T0604 x 1 m T0806 x 1 m AS3001F-08 SX5140-02 SX5120-01 AS3001F-06 AS3001F-06 AN101-01 AN101-01 AS4001F-10 T0604 x 1 m T1075 x 1 m T1209 x 1 m AS3001F-06 T0604 x 1 m AS3001F-06 T1075 x 1 m AS4001F-10 SX7140-03 SX7120-02 SV AS200-02
RS M W V T2 Applicable mounting bracket Bore size (mm) Weight (g) Joint 2D through 2O counter bore T1 B E J A type mounting bracket B type mounting bracket 32, 40 YU-03 YA-03 YB-03 25 50, 63 YU-05 YA-05 YB-05 40 Material: Carbon steel (nickel plated) mm 80 YU-08 YA-08 YB-08 90 100 YU-10 YA-10 YB-10 160 Bore size (mm) Part no.
Table 1 100 Total operation cycles (10,000) 50 40 30 20 10 100 200 300 400 500 700 1000 Stroke (mm) Table 2 10 Particle concentration (particles/m) Class M3.5 [Class100] 10 10 Class M2.5 [Class10] Inner cover holding screw tightening torque [Nm] 10 Tightening torque Model Screw size Class M1.5 [Class1] CYP15 0.3 M3 x 0.5 10 CYP32 2.45 M6 x 1 10 0.01 0.1 1 10 Plate Particle diameter (m) Note
Horizontal (without switch) Horizontal (with switch) 30 30 10 10 100 100 Load weight m (kg) Load weight m (kg) 80 5 5 80 63 63 50 50 40 40 1 1 0.5 0.5 32 32 25 25 20 20 0.1 0.1 10 100 10 100 Eccentric distance + Stroke L (mm) Eccentric distance + Stroke L (mm) m l S l: Eccentric distance (mm) S: Stroke (mm) L Allowable kinetic energy Pneumatic Circuits Extension locking, Without cushion Retraction
M AR50, 60 AR30, 40 J G J G A A IN OUT IN OUT H M M H Parts list Material Note No.
SS5V2-10 SS5V3-10 SS5V4-10 Note) The value is for manifold base with 5 stations and individually operated 2 position type.
The switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 2. Mount switches in locations where there is no vibration greater than 98 m/s2, or impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.
Use standard power supply cables for 3 m and 10 m lengths. Cleaning arm : Removable.
With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) Max. 16 stations Kit P Kit P Kit J Kit J Kit F Kit F L S The valve is equipped with an indicator light/surge voltage suppressor, and the voltage is 24 VDC. kit (Serial transmission unit) kit (Lead wire cable) The dust-protected type SI unit is applicable
Seal cap (10 pcs.) SPEEDCON and Its Related Parts The seal cap needs to be placed the unused I/O connector. The specified protection cannot be maintained. Power supply cable with M12 connector (5-pin B-coded) PCA-1564927 Straight 2 m PCA-1564930 Straight 6 m PCA-1564943 Right angle 2 m PCA-1564969 Right angle 6 m EX9-AWES For M8 EX9-AWTS For M12 Marker (1 sheet, 88 pcs.)
pressure: 0.5MPa (72psi) Evaluation of cleanliness inside chamber 100 Particle concentration (particles/cf) 10 Laser dust monitor 1 Laser dust monitor setting conditions 0.1 0.01 0.01 0.1 1 10 Cylinder operating conditions Particle diameter (m) 10-CM2XB20-50 Evaluation of cleanliness inside chamber 100 Particle concentration (particles/cf) Air cleaning system Clean gas filter 10 Clean gas
[mm] 1 D1 2 x Applicable tubing Weight [g] X (X) Y Nylon Urethane L1 M M L1 Oval type Round type 4 1/8 KQ2T04-01GS1 10 8.2 7.7 10 10 14.8 16.2 17.2 13.3 6 4.1 3 5.5 1/4 KQ2T04-02GS1 14 8.2 7.7 10 10 14.8 21.7 21.1 13.3 6 4.1 3 15 8 to 16 4, 6 A L2 6 1/8 KQ2T06-01GS1 10 10.4 9.7 12 10 15.5 17.3 19.4 13.3 13.9 11 4.5 6.1 1/4 KQ2T06-02GS1 14 10.4 9.7 12 10 15.5 22.8 23.3 13.3 13.9 11 4.5 15.6