Problem Cause Solution Connect the host and the thermocon with the following cables: A wrong connecting cable is used. A cross cable for RS-232C A straight cable for RS-485 Make the following settings of the host and the thermo-con consistent: The settings of the host and thermo-con are not consistent with each others.

Circuit of speed exhaust controller ASF Controlled by speed controller 15-13-3 4 Series ASV Dimensions (Hexagon width across flats) Applicable tubing O.D. d Metric Size Applicable tubing O.D. d T H D1 D2 L1 L2 L3 L4 A Max. Min. Max. Min.

Operation stop Related Equipment Combination Symbol: D1 Combination Symbol: D4 Application: The supply pressure is controlled by the external valve and a vacuum release is effected by the solenoid valve. Application: The supply pressure is controlled by the external valve and a vacuum release is effected by external air signals.

CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution : WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning : DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

Note No. 6 and 8 only function when a surface electric potential sensor is used. 2. 3. When a surface electric potential sensor is used, remove the cover cap plugging a modular jack for indicating [signal] on ionizer body, and insert a modular plug of sensor cable IZS30-CS.

Series Proper tightening torque (Nm) AS1002F-02 AS1002F AS2002F AS2052F AS3002F AS4002F 0.07 0.2 0.3 1 2 4 618 AS Series Speed Controller with One-touch Fittings In-line Type Dimensions L-bracket DIN rail mounting bracket Bracket on a single side Bracket on a single side AS-F AS-F L9 L16 L17 TMH L14 L15 ASD L12 L13 AS1002F AS2002F L22 L24 L23 AS L11 t1 2 x D6 t2 AS-FE 2 x D5 L19 KE AS-FG

KE AS-FG Dimensions AS-FP H1 AS-FM (Hexagon width across flats) AS-D Applicable tubing O.D. d AS-T H2 ASP (Hexagon width across flats) L4 L3 ASN L5 AQ ASV D1 L2 AK VCHC M M L1 ASR ASQ Metric Size Inch Size L4 Max. L5 (1) L5 (1) L4 Max. Weight (g) Weight (g) Panel-cut dimensions Panel-cut dimensions H1 H2 d D1 L1 L2 L3 M d D1 H1 H2 L1 L2 L3 M Model Model Min. Max. 34.4 Min.

Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB)

Controller Mounting: DIN Rail Mouting, Cable Length: 1 m, Inlet Port Silencer: AN10-01, 62 dB, Digital Pressure Switch: -, Exhaust Check Valve: -, Exhaust Solenoid Valve: -

Size: 16, Motor Mounting Position: D1 (In-line; Motor Cover Direction: Left), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included)

Protocol: 9 (EtherNet/IPâ„¢), Mounting: 8 (DIN Rail), Cable Connector: None, Actuator: LEY, Body Size: 16, Motor Mounting: D1 (In-line Cover Left), Lead: B (16: 5mm; 25: 6mm; 12; 32/40: 8mm), Stroke: 50mm

Series: LEY, Size: 16, Motor Mounting Position: D1 (In-line, Left Side), Motor Type: G (High Performance Battery-less Absolute, Step Motor, 24 VDC), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 40: 8mm), Stroke: 50mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End, Male Thread; 1 Rod End Nut is Included), Mounting: L (Foot Bracket, Parallel), Actuator Cable Type, Length: R5 (5m)

Series: LEY, Size: 16, Motor Mounting Position: D1 (In-line, Left Side), Motor Type: G (High Performance Battery-less Absolute, Step Motor, 24 VDC), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 40: 4mm), Stroke: 50mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End, Male Thread; 1 Rod End Nut is Included), Mounting: L (Foot Bracket, Parallel), Actuator Cable Type, Length: R5 (5m

Size: 16, Motor Mounting Position: D1 (In-line; Motor Cover Direction: Left), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R1 (1.5m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 7 (Screw Mounting

Size: 16, Motor Mounting Position: D1 (In-line; Motor Cover Direction: Left), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R1 (1.5m), Controller: C91 (Ether Net/IPâ

Size: 16, Motor Mounting Position: D1 (In-line; Motor Cover Direction: Left), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 50mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: F (Rod Flange, Top Mounting & In-line)

Size: 16, Motor Mounting Position: D1 (In-line; Motor Cover Direction: Left), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R5 (5m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)

Size: 16, Motor Mounting Position: D1 (In-line; Motor Cover Direction: Left), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R5 (5m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)