Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.
02 2 stations (5) (Not double wiring) One-touch fitting for 3.2 SI unit for MELSECNET/MINI-S3 Data Link System (2 power supply lines) (Mitsubishi Electric) (2) With name plate N BB One-touch fitting for 4 (1) 16 16 stations (6) External pilot R Max. 16 SI unit for SYSBUS Wire System (OMRON) SI unit for Satellite I/O Link System (Sharp) One-touch fitting for 6 C D E F1 G H J1 J2 K
Rated sensitivity current 10 {Ig1 Ign Iga K (Ig2 Igm)} [mA] (14.1) K: Constant considering the harmonic contents Cable Leakage current breaker K Type Products Noise NV NV-SP filter M Servo Cable Models provided with harmonic and surge reduction techniques NV-SW Driver amplifier NV-CP 1 NV-CW NV-L BV-C1 Ig1 Ign Iga Ig2 Igm General models NFB 3 NV-L Ig1: Leakage current on the electric channel
Rated sensitivity current 10 {Ig1 Ign Iga K (Ig2 Igm)} [mA] (14.1) K: Constant considering the harmonic contents Cable Leakage current breaker K Type Products Noise NV NV-SP filter M Servo Cable Models provided with harmonic and surge reduction techniques NV-SW Driver amplifier NV-CP 1 NV-CW NV-L BV-C1 MCCB Ig1 Ign Iga Ig2 Igm General models 3 NV-L Ig1: Leakage current on the electric channel
Pad diameter (mm) 4010 3507 2004 4 x 10 3.5 x 7 2 x 4 Vacuum entry port (Refer to Table (3) for applications.) 02 04 2 4 6 8 10 13 16 20 25 32 40 50 ZX 06 08 10 13 16 20 25 32 40 50 Buffer stroke (Refer to Table (2) for applications.) ZR ZM Buffer type ZH J K Rotating Non-rotating ZU ZL Material N S NBR Silicon rubber Pad type (Refer to Table (1) for applications.)
AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.
AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 2. Speed adjustment is possible with meter-in/meter-out type speed controllers, but it may not be possible to obtain the cushion effect (smooth start-up, soft stop). 3.
AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 Adjustment of Cushion Effect (Smooth Start-up, Soft Stop) Caution Since the external slider and piston slider are directional for size 10, refer to the drawings below when performing disassembly or maintenance.
AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.
2 Contact input signal 1: Run/Stop (Default setting) 4.7 k 1 k 3 Contact input signal 2: External switch (Default setting) 4.7 k 5 SD+ RS-485 communication 6 SD Internal circuit 7 SG 9 24 COM Circuit diagram Contact output signal 1: Operation status (Default setting) 10 Contact output signal 1 COM 11 Contact output signal 2: Alarm signal (Default setting) 12 Contact output signal 2 COM 13
-10AS G36-2-01 G46-2-02 G46-2-02 G46-2-02 G46-2-02 0.2MPa Note 3) GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS Note 1) Assembly includes a bracket and set nuts.
G VXD 3 0 21 VXD 3 0 21 5 1 02 G For Water For Oil For Air The AC (Class B) coil for VXD2130 comes with a full-wave rectifier.
) 02 2 stations N SD Note 2) SU Note 2) 11 11 stations W Note 1) Add 1 station for terminal block box mounting.
VH*-OMX0068-C PRODUCT NAME Pressure Relief 3 Port Valve with Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40-(F,N)02~(F,N)04(-B,S)(-K,M,R,Z)-D VHS40-(F,N)06(-B,S)(-K,M,R,Z)-D VHS50-(F,N)06~(F,N)10(-B,S)(-K,M,R,Z)-D VHS20W-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30W-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40W-(F,
Output data Offset Meaning MSB LSB MSB LSB (INT) 15 8 7 0 D4 #D3 #D2 #D1 #C4 #C3 #C2 #C1 #B4 #B3 #B2 #B1 #A4 #A3 #A2 #A1 Slave 8 connection diagnosis 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 In the figure above, #A1 to #A3 are slaves for which the connection is diagnosed. In this case, #A3 slave is not connected, and a diagnostic error is generated.
pins) Connector entry direction Note Symbol Note Symbol Stations Stations 1: Perpendicular connector 2: Lateral connector 02 02 2 stations 2 stations Double wiring Double wiring LOCK FREE FREE 08 04 8 stations 4 stations LOCK 02 02 2 stations 2 stations Specified layout (Up to 16 solenoids possible) Specified layout (Up to 8 solenoids possible) 16 08 16 stations 8 stations Note 1) Double
: 48.4 N02: 48.9 Atmospheric vent port 02 4 x 2.6 Depth 7 or less 20 30 25 8.5 11 R1/4 M5 x 0.8 Thread depth 5 4.2 N02 30 20 NPT1/4 17 Piping port 02: R1/4 N02: NPT1/4 2.5 If there is a possibility that the atmospheric vent port of the switch will be exposed to water or dust, insert a tube into the atmospheric vent port and route the other end of the tube to a safe place away from water or
In case of special wiring specification, put the option symbol "-K".
Model VQZ100 VQZ200 VQZ300 AN110-01 AN200-02 AN200-02 AN200-02 AN110-01 Port plug VVQZ100-CP (For VQZ100) This is used when changing piping location.
(32 [C]) : 293 [K] (20 [C]) : 12 [K] (= T0 Tt) : 900 [s] (= 15 [min]) Example of conventional units (Reference) : Unknown [cal/h] [W] : Water : (= r x V) [kgf] : 1 [kgf/L] : 20 [L] : 1.0 x 103 [cal/(kgfC)] Heat quantity by cooled substance (per unit time) Q Cooled substance Cooled substance weight m Cooled substance weight volume ratio c Cooled substance total volume V Cooled substance