Circulating uid outlet, Circulating uid return port Rc3/4 NPT3/4 or G3/4 Overow port Rc1 NPT1 or G1 Automatic uid ll port Rc1/2 NPT1/2 or G1/2 Facility water inlet, Facility water outlet Rc3/4 NPT3/4 or G3/4 (for HRS-EP029 or HRS-EP030) (It is not necessary to purchase this when pipe thread type F or N is selected in How to Order since it is included in the product.) Part no.

HEA e Return piping assembly r Barrel nipple (Size: 3/4 inch) (4 pcs.) IDH t Union (Size: 3/4 inch) (4 pcs.) y Sealant tape u Operation Manual 115 HRS100/150 Series y Snow Protection Hood Snow protection hood for air-cooled chiller.

Type PA3000 115 68 85 105 4-7 7.5 FLUID OUT Rc 3/8 5.5 AIR SUP (P1) Rc 1/4 FLUID OUT PROCESS PUMP P1 2 90 74.5 FLUID I N P2 44.5 3 AIR SUP (P2) 32 Rc 1/4 100 130 FLUID IN Rc 3/8 PA5000 179 4-9 90 90 FLUID OUT Rc 1/2, 3/4 AIR SUP (P1) Rc 1/4 112 56 165 56 RESET PROCESS PUMP FLUID OUT 167 P1 132.5 FLUID I N 125.5 103.5 P2 58.5 48.5 202 114 3.5 3 AIR SUP (P2) FLUID IN Rc 1/2, 3/4 Rc 1/4 10

) 4 3 42 2 1 4 Connector pin numbers 43 2-3.4 Pin name Pin No.

40 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 HRSH250--20 50 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 M5 A HRSH100--40 20 A 3 x 5.5 mm2 (3 x AWG10) (Power supply) 1 x 14 mm2 (1 x AWG6) (Grounding cable) R5.5-5 (Power supply) R14-5 (Grounding cable) HRSH150--40 HRSH200--40 HRSH250--40 3-phase 380 to 415 VAC (50/60 Hz) 30 A Note) An example

Model Pressure range *1 Indication unit Connection thread Note MPa Port size 01 Rc1/8 02 Rc1/4 R1/8 R1/4 G46-7-02-SRB 0 to 0.7 R1/4 G46-10-02-SRB 0 to 1.0 G46-4-01 to 02-SRB 0 to 0.4 MPa Set pressure range: 0.05 to 0.69 MPa 02 WR110 X215 *1: Do not apply more pressure than the max. pressure displayed. It may cause a malfunction.

Type (mm) 1in = 25.4mm PA3000 115 68 85 105 4-7 7.5 FLUID OUT 3/8 5.5 AIR SUP (P1) 1/4 FLUID OUT PROCESS PUMP P1 2 90 74.5 FLUID I N P2 44.5 3 AIR SUP (P2) 32 1/4 100 130 FLUID IN 3/8 PA5000 179 4-9 90 90 FLUID OUT 1/2, 3/4 AIR SUP (P1) 1/4 112 56 165 56 RESET PROCESS PUMP FLUID OUT 167 P1 132.5 FLUID I N 125.5 103.5 P2 58.5 48.5 202 114 3.5 3 AIR SUP (P2) FLUID IN 1/2, 3/4 1/4 10 Series

Type PA3000 115 68 85 105 4-7 7.5 FLUID OUT Rc 3/8 5.5 AIR SUP (P1) Rc 1/4 FLUID OUT PROCESS PUMP P1 2 90 74.5 FLUID I N P2 44.5 3 AIR SUP (P2) 32 Rc 1/4 100 130 FLUID IN Rc 3/8 PA5000 179 4-9 90 90 FLUID OUT Rc 1/2, 3/4 AIR SUP (P1) Rc 1/4 112 56 165 56 RESET PROCESS PUMP FLUID OUT 167 P1 132.5 FLUID I N 125.5 103.5 P2 58.5 48.5 202 114 3.5 3 AIR SUP (P2) FLUID IN Rc 1/2, 3/4 Rc 1/4 10

01 02 M5 1/8 (6A) 1/4 (8A) Electrical entry G-Grommet Orifice size N.O.

SMC offers a variety of pressure gauges including general purpose, oil-free/external parts copper-free with limit indicator, clean series and a pressure gauge with a pressure switch.  Pressure ranges vary from 0 to 1.5MPa, depending on the selected gauge.  Panel mounting is possible.General purpose gauge w/limit indicator , Back or vertical side thread , Indication precision: ±3% F.S. (full

Consider this key position when selecting sensor. 4 3 1 1 2 3 Input "1" (n+1) 0 Input "0" (n) side Input "1" (n+1) side 1 1 3 3 Input "0" (n) 2 4 key 4 2 M12 Block Sensor connector "0" Sensor connector "1" key 4 3 1 2 1 30 31 Input block up to 8 can be connected ( 16 points ). Input numbers are 0 15 from Input unit side.

Use tap water that conforms to the standards shown below (including water used for dilution of ethylene glycol aqueous solution). 4 h HEA 2 h 1 h 30 min 20 min 14 min 10 min IDH 6 min 4 min Tap Water (as Circulating Fluid) Quality Standards The Japan Refrigeration and Air Conditioning Industry Association JRA GL-02-1994 Cooling water system Circulation type Make-up water 2 min Operating

Number SS070A 01 1A O-ring FKM 10 SS070A-80A-1 Port size Clip Stainless steel 10 SS070A-80A-2 With 3.18/2 barb fitting With 4/2.5 barb fitting 01 02 Metal joint Stainless steel 10 SS070A-80A-3 Leaf spring Stainless steel 10 SS070A-80A-4 Mounting bracket Stainless steel 10 SS070A-80A-5 < U Side End Plate Assembly > 2 U side end plate assembly No.

L2 M 3 Y K T ISE70G 0~1 MPa ISE75G 0~2 MPa ISE76G 0~5 MPa ISE77G 0~10 MPa ISE78G 0~16 MPa 2 A A B B 02 Rc1/4 N02 NPT1/4 F02 G1/4 :ISO1179-1 1 M12 5m M12 5m T S : L IO-Link/1+2 NPNorPNP L2 1 M SI2 1 2kPaMPa / A ZS-50-A M46 2 B ZS-50-B M46 2 ZS-48-A ZS-31-B 5 m M12 ZS-31-C 5 m -9No.PS-OMV0008CN-E M12 4 24 OUT1 IO-Link OUT2 UP DOWN SET () ()() (() UP ON/OFF DOWN ON/OFF

4 030 s/0.01 -82No.PS-OMV0003CN-G ISE70 ISE71 IP67 AC1000 V 1 50 M(DC500 V ) 050 -1060 () 3585RH() UL/CSA(E216656)CE EMC RoHS IO-Link IO-Link V1.1 COM2(38.4 kbps) 5 IODD 2.3 ms (IO-Link ) Input Data2 byteOutput Data0 byte ID 131(0x0083) ID ISE70-*-L2-*307(0x0133) ISE71-*-L2-*308(0x0134) 1(0 ms) 2 3 MPa/kPa 490 5https://www.smcworld.com 6 02 N02 F02 Rc1/4 NPT1/4 G1/4 C3604

Silver, Body: Red Handle: Red Residual relief 3 port valve X116 Port size Body size Piping direction Left 1(P) Right 1(P) Thread type 02 1 4 Nil Rc 4 5 3 4 1 2 03 VHS40 3 8 0 1 N NPT 04 1 2 F G 06 VHS50 3 4 Applicable port size: 1/4, 3/8 Example of Operating Circuit JIS Symbol When using the valve, please refer to the table of applicable effective areas for the respective exhaust ports

23 21 56.2 50 ASP530F-N03-11S-X369 31.6 43.1 20.8 3/8 18.5 ASP630F-N04-11S-X369 24 33.6 47.9 61.8 20.8 NPT1/2 NPT1/4 17 28.6 25.6 70.3 ASP630F-N04-13S-X369 1/2 23.81 21.7 35.2 49.5 63.1 21.8 XTO Series T2 D 2-T1 L3 L2 L1 Model T1 T2 D L1 L2 L3 XTO-2571-02 Rc1/4 52 52 21 57 XTO-2571-03 Rc3/8 XTO-1239-02 Rc1/4 84 80 37 79 XTO-1239-03 Rc3/8 Rc1/4 XTO-1239-04 Rc1/2 XTO-1719-06 Rc3/4 98 98 40

Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM Model Port size (Rc) Rated flow rate (L/min) Model/Rated Flow Rate FH FH FH150-02 FH150-03 FH150-04 5 1/4 HOW 10 3/8 20 1/2 Description Part no.

Type 41 Applicable solenoid valve SYJ514-SYJ514M-SYJ524-SYJ524M-How to Order SS3YJ5--41-05 -C6 R port 1/8 Stations P, R port thread type A port size 02 : 20 P port 1/8 2 stations : 20 stations A A M5 01 C4 C6 N3 N7 M5 x 0.8 1/8 Nil Rc G NPT NPTF Applicable blanking plate assembly SYJ500-10-3A F N T 4 one-touch fitting 6 one-touch fitting A port M5 x 0.8, 1/8, C4, C6 5/32" one-touch fitting