Regarding controller, since it will be common to CE2 series, refer to Controller/ CEU2 on page 698 for details. 20 m (In the case of using our cable as well as our controller or counter.)
Dimensions/40 to 100 Basic/CA2YB 4-J 2-P (Rc, NPT, G) MM Width across flats KA G G D E H1 AL B1 K A N F N B C M S + Stroke H ZZ + Stroke (mm) Bore size (mm) 40 50 63 80 100 Stroke range Up to 500 Up to 600 Up to 600 Up to 700 Up to 700 B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10
Particle generation has been reduced to 1/20 compared to series 12-CY1B (previous P/A product), even without vacuum suction. Cleaned, assembled, inspected and double packaged in a clean room 10 Particle concentration (particles/m) Class M3.5 [Class 100] 10 10 Long strokes Class M2.5 [Class 10] 10 Long strokes are made possible by a special cylinder tube that does not bend.
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure(
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7, Specification
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: With bumper on both
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure(
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7, Specification
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: With bumper on both
Note) D-Y59A, Y69A, Y7P, Y7W, Z7, Z80 type cannot be mounted on the CP96 series.
Guide Suffix: 1 Axis, Bore Size: 10mm, Port Thread: Bore 10, 15: M Thread, Bore 20, 25, 32: Rc, Stroke: 150mm, Auto Switch: Y7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Guide Suffix: 1 Axis, Bore Size: 25mm, Port Thread: Bore 10, 15: M Thread, Bore 20, 25, 32: Rc, Stroke: 300mm, Auto Switch: Y7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal
Bore Size: Ø15, Thread Type: Bore 6-20: M Thread; Bore 25-32: Rc, Stroke: 20mm, Auto Switch: Y7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Bore Size: Ø20, Thread Type: Bore 6-20: M Thread; Bore 25-32: Rc, Stroke: 50mm, Auto Switch: Y7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal
Bore Size: Ø20, Thread Type: Bore 6-20: M Thread; Bore 25-32: Rc, Stroke: 75mm, Auto Switch: Y7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal
Bore Size: Ø25, Thread Type: Bore 6-20: M Thread; Bore 25-32: Rc, Stroke: 10mm, Auto Switch: Y7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Bore Size: Ø25, Thread Type: Bore 6-20: M Thread; Bore 25-32: Rc, Stroke: 50mm, Auto Switch: Y7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Bore Size: Ø25, Thread Type: Bore 6-20: M Thread; Bore 25-32: Rc, Stroke: 75mm, Auto Switch: Y7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)