SMC Corporation of America
Elite Part Number Search
Search Results "CXSJM6-10-M9NW"

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed, refer to SMC Best Pneumatics 2004 Vol.7/8/9/10 catalog. For details about auto switches with pre-wired connector, refer to SMC Best Pneumatics 2004 Vol.6 catalog.

(However, auto switch mounting brackets are assembled for the D-A9;/M9;;; before shipment.) 1 Series CA2 Specifications 100 80 63 50 40 Bore size (mm) Fluid Air Action Double acting Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Without auto switch: 10 to 70C Note 1) Ambient and fluid temperature With auto switch: 10 to 60C Note 1) Minimum operating pressure 0.05 MPa Piston speed

Maximum operating pressure 0.7 MPa Minimum operating pressure 0.05 MPa Auto switch proper mounting position (detection at stroke end) and its mounting height Without auto switch: 10 to 70C (No freezing) Ambient and fluid temperature With auto switch: 10 to 60C (No freezing) Minimum stroke for auto switch mounting Piston speed 50 to 1000 mm/s 30 to 700 mm/s Operating range mm + 1.4 0 Auto

to 80C With auto switch: 10 to 60C Ambient and fluid temperature 8 to 300 mm/s Piston speed Cushion seal type Cushion Rod Sizes +0.8 0 +1.25 0 +1.0 0 +1.4 0 +1.8 0 Stroke length tolerance to 100 st , 101 to 250 st , 251 to 630 st , 631 to 1000 st , 1001 to 1800 st (mm) Bore size (mm) 32 40 50 63 80 100 Note) Refer to page 214 for definitions of terms related to pressure.

to 80C Ambient and fluid temperature With auto switch: 10 to 60C CHA CHA Piston speed 8 to 300 mm/s Cushion Cushion seal Related Products +0.8 0 +1.0 0 +1.25 0 +1.4 0 +1.8 0 to 100st , 100 to 250st , 250 to 630st Stroke length tolerance D630 to 1000st , 1000 to 1500st Made to Order specifications For details, refer to page 415.

(Only auto switch mounting brackets are assembled at the time of shipment.) 316 Round Type Hydraulic Cylinder: 3.5 MPa CHM Series Specifications 20 25 32 40 Bore size (mm) Double acting/Single rod Hydraulic fluid 3.5 MPa 5.0 MPa 3.5 MPa 0.3 MPa Without auto switch: 10 to 80C With auto switch: 10 to 60C 8 to 300 mm/s None Action Fluid Nominal pressure Proof pressure Maximum allowable pressure

(However, they are auto switch mounting brackets are shipped with the mounting brackets mounted already). 297 CHN Series Specifications 20 25 32 40 Bore size (mm) Action Fluid Nominal pressure Proof pressure Maximum allowable pressure Minimum operating pressure Double acting/Single rod Hydraulic fluid 7 MPa 10.5 MPa 9 MPa 0.3 MPa Without auto switch: 10 to 80C With auto switch: 10 to 60C

cylinder (10 to 110C) -XC6 Madeofstainlesssteel -XC8 Adjustablestrokecylinder/Adjustableextensiontype -XC9 Adjustablestrokecylinder/Adjustableretractiontype -XC10 Dualstrokecylinder/Doublerodtype*1 Single clevis Mounting C: Single clevis Pivot bracket N: Yes Rod end bracket V: Single knuckle joint Auto switch D-M9BW: 2 pcs.

For other applicable auto switches, please contact SMC. 1 Series CM3 Specifications 20 25 32 40 Bore size (mm) Pneumatic Type Double acting, Single rod Action Air Fluid 145 psi (1.0 MPa) Proof pressure 102 psi (0.7 MPa) Maximum operating pressure 7 psi (0.05 MPa) Minimum operating pressure Without auto switch: 14 to 158F (10 to 70C) (No freezing) With auto switch: 14 to 140F (10 to 60C) (

Size Rod end thread 20 25 32 40 Piston area equivalent to 20 mm Piston area equivalent to 25 mm Piston area equivalent to 32 mm Piston area equivalent to 40 mm Rod end female thread Rod end male thread Nil M Cylinder stroke (mm) Size Stroke 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 20, 25 32, 40 Applicable Auto Switches/Refer to pages 13 through

MXY MTS Theoretical Output (N) Operating pressure (MPa) Cylinder bore (mm) 6 8 12 Piston area (mm2) 0.2 6 10 23 0.55 15 28 62 Magnetic Holding Force (N) 0.5 14 25 57 0.4 11 20 45 0.3 8 15 34 28 50 113 Made to Order Specifications (Refer to pages 1955 to 2021 for details.)

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ For details about auto switches with pre-wired connector, refer to Best Pneumatics No. 2. Auto switches are shipped together, (but not assembled).

freezing) With auto switch: 10 to 60C (with no freezing) Ambient and fluid temperature CLJ2 Lubrication Stroke length tolerance Piston speed Port size (Rc, NPT, G) Non-lube CLM2 +1.0 0 mm 50 to 500 mm/s CLG1 1/8 1/4 Note) The minimum operating pressure of the cylinder is 0.1 MPa when the cylinder and lock are connected to separate ports.

Symbol Specications -XAl Change of rod end shape -XB6 Heat resistant cylinder (10 to 150C)1 CA2 -XB7 Cold resistant cylinder (40 to 70C)2 CS1 -XB9 Low speed cylinder (10 to 50 mm/s) -XB13 Low speed cylinder (5 to 50 mm/s) -XC4 With heavy duty scraper -XC6 Made of stainless steel -XC8 Adjustable stroke cylinder/Adjustable extension type -XC9 Adjustable stroke cylinder/Adjustable retraction

length [m] Pre-wired connector Applicable load DC AC 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Load voltage Auto switch model Indicator light Wiring (Output) Type Special function Electrical entry M9N V V V v v IC circuit 3-wire (NPN) Solid state auto switch 5 V, 12 V 3-wire (PNP) M9P V V V v v 2-wire 12 V M9B V V V v v Diagnostic indication (2-color indicator) Grommet Grommet 3-wire (NPN) 5 V, 12 V M9NW

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state switches marked with are produced upon receipt of order. Since there are other applicable auto switches than listed above, refer to the Best Pneumatics No. 2 for details.

Pilot port * Details of the mounting bolts P. 6 Stroke/Minimum stroke for auto switch mountings P. 15 Bore size Standard stroke [mm] 5 10 15 20 25 30 35 40 45 50 12 16 20 25 Applicable Auto Switches/Refer to the Web Catalog or Best Pneumatics for further information on auto switches.

Lead wire length symbols: 0.5 m Nil (Example) M9NW 3 m L (Example) M9NWL 1 m M (Example) M9NWM 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. Since there are applicable auto switches other than those listed above, refer to page 30 for details. The D-A9l/M9l/P3DWAl auto switches are shipped together, but not assembled.

Indicator light Load voltage Lead wire length (m) Applicable load Auto switch model Tie-rod mounting Band mounting Wiring (Output) Special function Type Electrical entry Pre-wired connector 1 (M) DC AC 0.5 (Nil) 3 (L) 5 (Z) M9N M9P M9B G39C K39C M9NW M9PW M9BW M9NA*1 G59 G5P K59 G39 K39 G59W G5PW K59W G5BA*1 3-wire (NPN) 5 V, 12 V IC circuit 3-wire (PNP) Grommet 24V 12 V 2-wire

(Except 10) Applicable Auto Switches/Refer to pages 1575 to 1701 for further information on auto switches.