Nominal Size: 25, Speed Specifications: Standard 100 to 1000, Load Specifications: Standard Load, Nominal Size: 16(5), 25(10), Stroke: 400mm, Motor Placement: DA [On the Bottom (Left)], Output Type: PNP, Stoppable Positioning Points: A [5 Point (2 Ends + 3 Intermediate)], Cable Length: 5m, Auto Switch: M9P--Solid State, Gen.
Nominal Size: 25, Speed Specifications: Standard 100 to 1000, Load Specifications: Standard Load, Nominal Size: 16(5), 25(10), Stroke: 1000mm, Motor Placement: TB [On the Top (Right)], Output Type: PNP, Stoppable Positioning Points: A [5 Point (2 Ends + 3 Intermediate)], Cable Length: 5m, Auto Switch: M9P--Solid State, Gen.
Style: H (Single Axis Type), Size: 32, Motor Mounting Position: LU (Symmetric, Bottom Mounting), Stroke: 100, Motor Option: w/o Option, Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 2P [LECP2, Programless Type (w/Stroke Study), PNP], I/O Cable Length for LEC: 5 (5m)
Style: H (Single Axis Type), Size: 25, Motor Mounting Position: Top Mounting, Stroke: 100, Motor Option: w/o Option, Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 2P [LECP2, Programless Type (w/Stroke Study), PNP], I/O Cable Length for LEC: 5 (5m)
Style: HT (Double Axis Type), Size: 32, Motor Mounting Position: Top Mounting, Stroke: 100, Motor Option: w/o Option, Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 2P [LECP2, Programless Type (w/Stroke Study), PNP], I/O Cable Length for LEC: 5 (5m)
Style: H (Single Axis Type), Size: 32, Motor Mounting Position: U (Bottom Mounting), Stroke: 100, Motor Option: w/o Option, Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 2P [LECP2, Programless Type (w/Stroke Study), PNP], I/O Cable Length for LEC: 5 (5m), Controller Mounting: D (DIN Rail Mounting)
Style: Single Axis Type, Size: 32, Motor Mounting Position: Symmetric, Bottom Mounting, Stroke: 100, Motor Option: w/o Option, Actuator Cable Type: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: 2P [LECP2, Programless Type (w/Stroke Study), PNP], I/O Cable Length for LEC: 5m, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for JXC: -
Style: Single Axis Type, Size: 32, Motor Mounting Position: Bottom Mounting, Stroke: 100, Motor Option: w/o Option, Actuator Cable Type: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: 2P [LECP2, Programless Type (w/Stroke Study), PNP], I/O Cable Length for LEC: 5m, Controller Mounting: DIN Rail Mounting, Communication Plug Connector or I/O Cable Length for JXC: -
Style: Single Axis Type, Size: 25, Motor Mounting Position: Top Mounting, Stroke: 100, Motor Option: w/o Option, Actuator Cable Type: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: 2P [LECP2, Programless Type (w/Stroke Study), PNP], I/O Cable Length for LEC: 5m, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for JXC: -
Style: Double Axis Type, Size: 32, Motor Mounting Position: Top Mounting, Stroke: 100, Motor Option: w/o Option, Actuator Cable Type: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: 2P [LECP2, Programless Type (w/Stroke Study), PNP], I/O Cable Length for LEC: 5m, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for JXC: -
Table 7-1 Quality criteria for clean water (tap water) Standard value Item Unit For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Sulfuric acid ion [mg/L] 50 or less 200 or less Standard item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness
Series CBQ2 Allowable Kinetic Energy Allowable Rod End Lateral Load 0.5MPa 0.4MPa With rubber bumper With auto switch (lateral resistance) 200 100 100 50 50 40 30 Allowable lateral load W (N) 63 20 Load weight kg 50 10 63 40 32 10 5 4 3 50 5 2 40 1 0 10 20 30 40 50 60 70 80 90 100 32 Stroke St (mm) 1 50 100 200 500 300 Maximum speed mm/s (Mounting orientation: Horizontal) W
In the case the wiring length to load is more than 5m. 3. In the case the load voltage is 100 or 200V AC. Be sure to use the contact protection box in any case mentioned above. Otherwise, the contact life may be shortened. (Due to permanent energizing conditions.)
kPa 2.0 64 5 m 100 kPa 0.05mm 0.05mm [s] [s] [mm] [mm] 1.5 64 100 kPa 0.15 mm 2.0 64 100 kPa 0.3 mm [s] [s] [mm] [mm] -21No.PS-OMF0005CN-E ISA2-G ISA2-H 100 kPa 1.5 64 5 m 100 kPa 2.0 64 5 m [mm] [mm] [kPa] [kPa] -22No.PS-OMF0005CN-E ISA2 () 1 ON ( +)ON ()ON OFF Yes 2 No ( OFF +)ON 1 ()ON 3 ()ON 1,3 OFF 4 5 ON OFF 6 7 8 -23No.PS-OMF0005CN-E No.
Induction load Lead wire length greater than 5m (Standard model: 0.5m) 100VAC **In case of "D-B59W", red light illuminates at sensitive position and green illuminates at most sensitive position.
200 50 100 50mm/s 20 25 32 40 0 1.0 0 2.0 10 Time [s] Cylinder size [mm] 4.10-2 Series RHC low/medium speed opration with heavy loads 20 , 25 , 32 , 40 Cushion Ring MK/MK2 RSQ/RSG The long cushion ring can absorb larger energy (in terms of speed and weight).
L (Example) C73CL 5m . Z (Example) C73CZ None .
200 4x20 700 (100) 800 355 4x20 Auto drain is included in the package.
Table 8-1 Quality standard for fresh water (tap water) Item Product Standard value For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Sulfuric acid ion [mg/L] 50 or less 200 or less Standard item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness