Type: [Related Components (Auxiliary Devices)] Bracket, Compressed Air Quality: Fluid, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 3/8, Filtration Level: -, Operating Environment: Standard, Drain Cock: -, Bowl Material: -, Bowl Guard: -, Specification: -, Size of Body: -, Accessory: -, O-Ring, Gasket Material: -, Custom-made Specifications: -, Nominal of pipe flange: -, Connection

Type: [Related Components (Auxiliary Devices)] Bracket, Compressed Air Quality: Fluid, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/2, Filtration Level: -, Operating Environment: Standard, Drain Cock: -, Bowl Material: -, Bowl Guard: -, Specification: -, Size of Body: -, Accessory: -, O-Ring, Gasket Material: -, Custom-made Specifications: -, Nominal of pipe flange: -, Connection

Type: [Related Components (Auxiliary Devices)] Bracket, Compressed Air Quality: Fluid, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 3/4, Filtration Level: -, Operating Environment: Standard, Drain Cock: -, Bowl Material: -, Bowl Guard: -, Specification: -, Size of Body: -, Accessory: -, O-Ring, Gasket Material: -, Custom-made Specifications: -, Nominal of pipe flange: -, Connection

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Size: 16, Motor Mounting Position: D1 (In-line; Motor Cover Direction: Left), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included)

Size: 16, Motor Mounting Position: D1 (Size 16, In-line, Left Side), Motor Type: H (Battery-less Absolute, Step Motor 24 VDC), Lead, mm: A (Size 25: 12; Size 32: 16; Size 40: 20), Stroke: 500mm, Motor Option: without Option, Grease Application: N (without, Roller Specification), Controller Position: B (Integrated Controller), Parallel Input: 6 (PNP)

M1 Weight (g) 4 6 6 8 6 8 10 8 10 8 10 10 12 Applicable tubing O.D. d T H D1 D2 L1 L2 L3 Model AS121-M5-F04 AS121-M5-F06 AS221-01-F06S AS221-01-F08S AS221-02-F06S AS221-02-F08S AS221-02-F10S AS321-02-F08S AS321-02-F10S AS321-03-F08S AS321-03-F10S AS421-04-F10S AS421-04-F12S 16 17 17 18.5 17 18.5 21 18.5 21 18.5 21 21 22 13 13 34 31 54 50 52 86 81 93 88 154 146 21 21.5 25.5 26 M5 x 0.8 28.3

driving force Fn (N) Allowable driving force Fn (N) CY1S 100 500 400 50 300 30 200 CY1L 100 10 20 30 40 50 Usable range CY1H 5 Usable range CY1F 1 0 1 2 3 4 5 6 10 7 8 9 10 11 12 13 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CYP CY3R25 500 Allowable driving force Fn (N) 300 200 100 20 30 40 50 10 Usable range 5 D1

L1 L2 A (2) L3 H (1) T2 T1 D1 D2 Model ASR ASQ AS1200-M3 M3 x 0.5 M3 x 0.5 4.5 6.6 23.5 21.5 8 5 5 20.5 18.5 AS120-M5 M5 x 0.8 M5 x 0.8 8 10 28.3 10.3 9 9 25 22.2 25.5 AS120-U10/32 10-32UNF 10-32UNF AS220-01 30.5 13.2 14.3 14.6 32.4 27.4 12 (12.7) 18 35.5 1/8 1/8 AS220-02 35.3 17.5 18 19.5 34.8 29.8 17 (17.5) 27.2 40.3 1/4 1/4 AS320-03 40.8 19.7 22.5 24.3 40.6 35.6 19 30 45.8 3/8 3/8 AS420

D 6 D1 mm, 6 < D 25 D2 mm, D > 25 D4 mm 3. In the case of double rod type and single acting retraction type, enter the dimensions when the rod is retracted.

D1. Fix the auto switch on the auto switch mounting bracket with the auto switch mounting screw (M4) and install the set screw. 2. Fit the auto switch mounting bracket into the cylinder tie-rod and then fix the auto switch at the detecting position with the hexagonal wrench. (Be sure to put the auto switch on the surface of cylinder tube.) 3.

D-Y7P(V) D-Y7NW(V), D-Y7PW(V), D-Y7BW(V) D-Y7BA Reed D-Z73, D-Z76, D-Z80 A B A B CHQ Auto switch mounting screw M2.5 x 4 L CHK CHK (Attached to the auto switch) M3 x 6 L CHN M3 x 6 L Auto switch (Attached to BHK2-032) (Attached to BHK2-032) CHM Auto switch mounting bracket BMG2-012 CHS Auto switch mounting bracket Auto switch mounting bracket BHK2-032 BHK2-032 CH2 CHA Related Products D1

comes to feel tight. 342 Auto Switch Mounting CHSD Series How to Mount and Move the Auto Switch Solid state D-F59, D-F5P D-J59, D-F5BA D-F59W, D-F5PW, D-J59W D-F59F, D-F5NT Reed D-A53, D-A54, D-A56, D-A64, D-A67 D-A59W CHQ CHK CHN Auto switch mounting screw (M4) CHM CHS CHS Auto switch CH2 Auto switch mounting bracket Set screw (M4) CHA Related Products Tie-rod D1

M=I 2) SMC will make appropriale arrangemen1S il no d1 mensions, tolerance. or 1mish inslruclions are given in the diagram. 3) The possible range of lie-rod length is listed in the table below. 4) The M dimension of the bracket mounhng side 01 Flange (F, G). Clevis (C. D) types cannot be specified.

Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d33d1 Flow control valve 3d3 d2 Air supply Filter Shut off valve Flow meter 3d2 10d2 3d1 10d1 10d3 Pipe for measuring temperature Pipe for measuring pressure on the upstream side Test equipment Pipe for measuring pressure on the downstream side Fig.

Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d33d1 Flow control valve 3d3 d2 Air supply Filter Shut off valve Flow meter 3d2 10d2 3d1 10d1 10d3 Pipe for measuring temperature Pipe for measuring pressure in the upstream side Equipment for test Pipe for measuring pressure in the downstream side

Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter d1 Pressure control d3 3d1 equipment Flow control 3d3 valve d2 Filter Air Flow meter Shut off 3d2 10d2 3d1 10d1 10d3 supply valve Pipe for measuring Equipment temperature for test Pipe for Pipe for measuring measuring pressure in the pressure in the downstream side upstream side

Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d33d1 Flow control valve 3d3 d2 Air supply Filter Shut off valve Flow meter 3d2 10d2 3d1 10d1 10d3 Equipment for test Pipe for measuring temperature Pipe for measuring pressure in the upstream side Pipe for measuring pressure in the downstream side

Bore size (mm) UA C d1 d2 H K L UT Weight (g) 6.5 12 22 60 120 14 YB-05 50, 63 11 17 6 32, 40 7 15.8 14 M8 X 1.25 8 25 YU-03 13 17 6 50, 63 7 19.8 18 M10 X 1.5 10 40 YU-05 8.5 16 28 75 230 18 YB-08 80 20 22 8 80 9 24.8 23 13 90 M16 X 2 YU-08 10.5 18 36 90 455 YB-10 100 26 26 10 100 11 29.8 28 14 160 M20 X 2.5 YU-10 2.3-19 Series CDQ2 Auto Switch Mounting Position (at Stroke End) and Mounting