Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, TUBE CAP, CONNECTORS, KQ2 FITTING, BP, KQ2 1/8, 0.00035 lb

Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, TUBE CAP, CONNECTORS, KQ2 FITTING, BP, KQ2 1/8, .00022 lb

Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, TUBE CAP, CONNECTORS, KQ2 FITTING, BP, KQ2 1/8, .00035 lb

VALVE, RELIEVING, AIRLINE EQUIPMENT, AP BP RELIEF REGULATOR, CD, AP 1/8INCH STANDARD (NPT), .24250 lb, ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R 1/8M5 x 0.8Case: C3604 + nickel plated, Piping port/pressure sensor: Stainless steel 316LPSE56 - : Oil proof heavy-duty vinyl cable with air tube, 3 cores, ?

Single acting nomally open: O.D. holding force, Single acting nomally closed: I.D. holding force Refer to "Effective Holding Force" for the holding force at each holding position, page 13 to 17. 11 Series MHK2 Wedge Cam Operation Gripper Construction Double acting Single acting ck 3 bs br 2 9 Open finger Normally open bt 5 6 bp 8 7 bq 1 4 bl bk bm Closed finger Normally closed bo bn Parts

12 16 20 25 10,20,30,40,50,75 10,20,30,40,50,75,100 10,20,30,40,50,75,100,125 10,20,30,40,50,75,100,125,150 10,20,30,40,50,75,100,125,150 Stroke adjuster/shock absorber option BS BT With shock absorber at extension end* With shock absorber at retraction end* *Shock absorber option is not available for MXS6 52 Air Slide Table MXS Series Construction/Parts list, Seal list 3 6 8 9 br bs bt bp

Lubricant Table ttanuf9ctuf's I LuDrrcrm BP THB 32 Castrol Perfecto T32 ESSO/Exxon TERESSO 32 Mobil DTE Lig ht Shell Turbo T32 @ 4 Port Solenoid Yalve NVZlOOO Symbol NVZ1120 A B NVZ1120-OG-t\,ts-F NVZlI2GOG.M5 Model o.2 (90) Spec ifications Air, Inert gases Operating Pressure range 20-1ooPst(1.5Ambient and fluid Max.120'F(50"C) Response time 15 ms or less (atTOPSI) Max.operating 900 cpm

5 .38 .71 .65 t 1 t.37 .71 .63 .n SLA 9/l6ll Ex.50 stA ir r34 (rR)0rM.35 .5 to .63 tl5 18 lJNt .31 r.55 .tl .63 .18 SlAVl-|6 x-50 5tA 338{7 trRl0Eril.5 .5 .94 .55 V,r . 16 Uflt .43 r.64 .98 .88 ,28 SLAl -l2xl 5ta 33848 (rRloEMt.01.0 1.50 1.80 I,r2 UNt .59 2.88 1.42 1.25 .39 \oles: L To bp used d t r -or D-fio1 -odpl\ ontt 2.

Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, TUBE CAP, CONNECTORS, KQ2 FITTING, BP, KQ2 1/8, .00009 lb

Auto switch model Applicable bore size (mm) 23.6 55.0 OUT 39.3 44.5 104 IN 74.2 15 D-90/97 D-90A/93A 53.0 124 OUT 88.3 6, 10, 15 BP-1 OUT IN 6-2-8 3 Series CJP Pin Cylinder Single Acting, Single Return Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height D-90, D-90A Most sensitive position and operating range of auto switch (a) Operating range Most sensitive

Auto switch model Applicable bore size (mm) 23.6 55.0 OUT 39.3 44.5 104 IN 74.2 15 D-90/97 D-90A/93A 53.0 124 OUT 88.3 6, 10, 15 BP-1 OUT IN 6-2-8 3 Series CJP Pin Cylinder Single Acting, Single Return Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height D-90, D-90A Most sensitive position and operating range of auto switch (a) Operating range Most sensitive

Series BP regulator was designed for general use in a wide variety of applications. Available options include Hastelloy® internals for corrosion resistance, panel installation, and a variety of pressure gauges in psig/bar or MPa units. Operating pressure: 0.5 to 300 psig; Stainless steel or brass construction

Series BP regulator was designed for general use in a wide variety of applications. Available options include Hastelloy® internals for corrosion resistance, panel installation, and a variety of pressure gauges in psig/bar or MPa units.

10 μin. (0.25 μm), Standard, Ports: 2PW [2 Ports (1-In; 2-Out)], Connections, Inlet: FV4 (1/4 Inch Face Seal, Female), Connections, Outlet: FV4 (1/4 Inch Face Seal, Female), Gauge Port, Inlet: No Gauge Port, Gauge Port, Outlet: No Gauge Port, Pressure Gauge Unit: psig/bar (or None in the Case of No Gauge), Seat Material: PCTFE, Standard, Flow Specification: Standard, Cv: 0.09, Bonnet: BP

Surface Finish: 10 μin. 0.25 μm, Standard, Ports: 2PW [2 Ports (1-In; 2-Out)], Connections, Inlet: FV8 (1/2 Inch Face Seal, Female), Connections, Outlet: MV8 (1/2 Inch Face Seal, Male), Gauge Port, Inlet: No Gauge Port, Gauge Port, Outlet: No Gauge Port, Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Seat Material: PCTFE, Standard, Option: HF (High Flow, CV: 1.1), Bonnet: BP

[CR] No. 0 2ROM 1 E SMC 2ROM 2 E , )10 1 36 - # 0 0 E E [CR] No. ,2 0 1 , 0 2 , 0 3 0 4 0 5 OFF , 0 6 () 0 7 () 0 8 () 0 9 () 37 - 9 BCD CEU5B-BCD (1) BCD : D-sub (CEU5B-D ) DX10M-36S(HRS ) (2):DX30AM-36P(:HRS ) DX30M-36-CV(:HRS ) ()(), ,ASSY MISUMI SHPT SHPT-H-A-36SHPT-HH-A-36:0.250(m) (3) 18 (DX10M-36S) 19 36 -2 Bit0 19 D12 10 1 Bit0 1 D0 10 -2 Bit1 20 D13 10 1 Bit1 2 D1

. -3- 1Specification 1.1 How to Order L E S Y H 8 D1 E A 50 R1 CD17T (1) (2) (3) (4) (5) (6) (7) (8) (1) Size (3)Motor type (2)Motor mouting position/Motor cover direction 8 Symbol type Compatible symbol Motor mouting position Motor cover direction controller 16 25 D1 Left side JXCE1 JXCL1 D2 Right side JXC91 JXCM1 E Battery-less absolute (Step motor 24V DC) In-line D3 Upper side JXCP1 JXC51