Body Size: 20, Thread: Rc, Port: 01 (1/8), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: KV (K + V), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 20, Thread: Rc, Port: 01 (1/8), Option: Standard, Attachment: KV (K + V), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 30, Thread: N (NPT), Port: 03 (3/8), Option: Standard, Attachment: KV (K + V), Semi-Standard 1: 3 (Lubricator w/Drain Cock), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 30, Thread: N (NPT), Port: 03 (3/8), Option: DE (D + E), Attachment: KV (K + V), Semi-Standard 1: 3 (Lubricator w/Drain Cock), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 40, Thread: N (NPT), Port: 04 (1/2), Option: D [Float Type Auto Drain (N.O.)], Attachment: KV (K + V), Semi-Standard 1: 3 (Lubricator w/Drain Cock), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 20, Thread: N (NPT), Port: 02 (1/4), Option: C [Float Type Auto Drain (N.C.)], Attachment: KV (K + V), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 20, Thread: N (NPT), Port: 02 (1/4), Option: C [Float Type Auto Drain (N.C.)], Attachment: KV (K + V), Semi-Standard 1: 3C (3 + C), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 30, Thread: N (NPT), Port: 02 (1/4), Option: E [Square embedded type pressure gauge (with limit indicator)], Attachment: KV (K + V), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 30, Thread: N (NPT), Port: 03 (3/8), Option: E [Square embedded type pressure gauge (with limit indicator)], Attachment: KV (K + V), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 20, Thread: Rc, Port: 02 (1/4), Option: Standard, Attachment: KV (K + V), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 20, Thread: N (NPT), Port: 01 (1/8), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: KV (K + V), Semi-Standard 1: 1C (1 + C), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 20, Thread: N (NPT), Port: 01 (1/8), Option: Standard, Attachment: KV (K + V), Semi-Standard 1: 1C (1 + C), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 30, Thread: N (NPT), Port: 03 (3/8), Option: CE (C + E), Attachment: KV (K + V), Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 40, Thread: Rc, Port: 04 (1/2), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: KV (K + V), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40, Thread: Rc, Port: 04 (1/2), Option: Standard, Attachment: KV (K + V), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Note) Metric size 6, 8, 10 10, 12 Inch size 1/8", 3/16", 1/4" 1/4", 3/8" 3/8", 1/2" LVC Orifice diameter 4.4 8 10 0.4 1.2 1.8 Flow rate characteristics Av x Kv LVA 0.5 1.4 2.2 Cv Withstand pressure (MPa) 1 LVH Operating pressure (MPa) 0 to 0.5 Fluid temperature (C) 5 to 90 LVD Ambient temperature (C) 0 to 60 Weight (kg) LVQ 0.055 0.115 0.185 Note) For details of the applicable tubing sizes
A0202 IZS30 (1 replacement rubber grindstone) Rubber grindstone Felt pad 185 Gun Type Ionizer IZG10 Series Specifications AC Adapter Specifications Ionizer model IZG10 Ion generation method Corona discharge type Method of applying high voltage High frequency AC type Applied voltage*1 2.5 kV Offset voltage*2 Within 10 V Input voltage*4 100 to 240 VAC 50/60 Hz Output voltage 24 VDC 5% Output
Supply pressure: 0.1 MPa (7 L/min (ANR) per nozzle) Installation height of sensor: 10 mm 3 Electrostatic potential [kV] 20 With sensor Ionizer 2 Without sensor Without sensor Discharge time [s] 15 1 With sensor L 0 10 1 Workpiece Without sensor 5 2 With sensor 3 0 500 1000 1500 2000 Installation distance L [mm] 1 2 3 4 Time [s] Run mode after static neutralization (electrostatic potential
The discharge speed has been increased by reading the workpiece's electrostatic potential by the feedback sensor (option) and continuously emitting ions with a reverse polarity. 3 Electrostatic potential (kV) With sensor IZS IZS Detects the polarity of a discharged object and measures the charged voltage. 2 Without sensor 1 IZN 0 IZF 1 Without sensor 2 With sensor ZVB 3 1 2 3 4 Time (s) IZD
Note) Metric size 6, 8, 10 10, 12 Inch size 1/8", 3/16", 1/4" 1/4", 3/8" 3/8", 1/2" LVC Orifice diameter 4.4 8 10 0.4 1.2 1.8 Flow rate characteristics Av x Kv LVA 0.5 1.4 2.2 Cv Withstand pressure (MPa) 1 LVH Operating pressure (MPa) 0 to 0.5 Fluid temperature (C) 5 to 90 LVD Ambient temperature (C) 0 to 60 Weight (kg) LVQ 0.055 0.115 0.185 Note) For details of the applicable tubing sizes