SMC Corporation of America
Elite Part Number Search
Search Results "CM2FZ40-250FZ"

Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Type: N (Rubber Bumper), Bore: 80mm, Port Thread Type: TN [NPT ø20 to ø100 Rubber Bumper, ø32 to ø100 Air Cushion), Stroke: 250mm, Thread: F (Female Rod End), Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewire Connection: 0.5m (Or None in the Case of No Switch),

Magnet: D (Built-in Magnet), Mounting: B (Basic), Type: N (Rubber Bumper), Bore: 20mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 250mm, Thread: F (Female Rod End), Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewire Connection: 0.5m (Or None in the Case of No Switch),

Magnet: D (Built-in Magnet), Mounting: D (Clevis), Type: A (Air Cushion), Bore: 32mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 250mm, Thread: F (Female Rod End), Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: N (Pivot Bracket not Assembled)

Magnet: D (Built-in Magnet), Mounting: B (Basic), Type: A (Air Cushion), Bore: 50mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 250mm, Thread: F (Female Rod End), Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewire Connection: L (3m)

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: NPT,

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: A93, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9N, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread type

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread type

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: M5 × 0.8, Auto Switches: Without auto

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: M5 × 0.8, Auto Switches: Without auto

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.18 to 1.0, Specification: Built-in magnet, Auto Switches: M9P, Lead Wire Length(m): 5, The number

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch,

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: M9B, Lead Wire Length

Magnet: Built-in Magnet, Mounting: Axial Foot, Bore Size: 20mm, Port Thread: NPT, Stroke A: 25mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: -, Cushion: Rubber Bumper, Rod End Thread B: Female Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number

Magnet: Built-in, Type: Pneumatic, Mounting: Basic, Bore: 20mm, Port Thread: Rc, Stroke: 250mm, Cushion: Rubber Bumper, Rod End Thread: Female Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Leadwire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -