SMC Corporation of America
Elite Part Number Search
Search Results "CDM2F25TNP-350-M9PSAPC-C"

Turn the manual override counterclockwise by 180 to set the E mark to "0", then it will be reset. 200V AC 220V AC Red Red 200V AC 220V AC Indicator light With light and surge voltage suppressor Circuit for DC Circuit for AC Light A () A (+) SOL SOL C (+) C ZNR Light () Due to the use of non-polar light, the VQZ series has no polarity.

Nil L R S a b h g d c f e Operating direction Left Right Note) Plugs are installed in ports other than those indicated for the model.

Reduced outgassing Resin materials eliminated Laser marking is employed for the model designation. o u d t g e 2 a c s u s d i Reduction of outgassing due to surface treatment e n o u d t g R e g a 1 c s u s d i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.

Reduced outgassing o u Resin materials eliminated Laser marking is employed for the model designation. d t g e a c 2 s u s d i e Reduction of outgassing due to surface treatment n o u d t R g g e a c 1 s u s d i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.

A B C D E F A B C D E F G H Pressure port Pressure port Right Left Left Right Left Right Right Left Left Right Right Left Left Right Operating direction Operating direction There are 9 possible reciprocating piping methods. There are 16 possible reciprocating piping methods.

Standard stroke -X Bore size (mm) Standard stroke (mm) Piping port location 15, 32 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700 Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left a b c d e f g h 20Nil Note 1) Please consult

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Leakage test result a t e l u g c Stainless steel linear guide & low particulate generation vacuum grease e i 2 t n r a e CX p r a 0.0 10 0 20 10 w 10-10 0 5 10 t i o o n L DTime [min] Operation cycles -X e e a a l l k k a t e l u w w g a a c 2 e i o

H 4 S y m b o l Initial power/ Power 100 VAC 600/150 800/220 1200/350 200 VAC 2400/150 3200/220 4800/350 consumption (W) Heater assembly number XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 2 pcs. 3 pcs. 4 pcs.

G MADE IN IDF100150F-W i.2 i-6 IDX-OM-Z004 i i.3 HFC IDF100150F-W i.3 i-7 IDX-OM-Z004 i i.4 / 1 1.5 () IDF100150F-W i.4 / i-8 IDX-OM-Z004 1 1 1.1 i.2.9 1 2 IDF100F-30-W C,RV IDF100F-30-CRVW4 IDF 100 F 30 W 4 C 5 G ) K 100kW 100 P 125kW 125 150kW 150 R ) V AC200V(50Hz) AC200/220V(60Hz) 30 1 4 5 C G K P R V 1.1 IDF100150F-W 1 1 IDX-OM-Z004 1 1.2 1.2.1 (C) 1.2.2 G 1.2.3

/ AC200V 2400/150 3200/220 4800/350 Ass'y XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 Ass'y 2 3 4 H5 AC100V 800/180 1200/300 1600/400 / AC200V 3200/180 4800/300 6400/400 1)/ 2)16 PTC() 200V 200 PTC 150 100V PTC Ass'y 0 5 10 15 20 25 30 Ass'y ( Ass'y 30 8 XL-OMV0002 4 4-1.162540 Assy SUS304 SUS316L ( SUS304) ( A6063) C D C E E (KF ) Fn J H B A G A mm A B C D E Fn G H J XLC

H 4 S y m b o l Initial power/ Power consumption (W) 100 VAC 600/150 800/220 1200/350 200 VAC 2400/150 3200/220 4800/350 Heater assembly number XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 2 pcs. 3 pcs. 4 pcs.

All data given in a technical specification sheet is based on 25[C]. The temperature range is dependent on the product series. Normally SMC products are rated from 0 to 50[C] or 0 to 60[C].

+ COM (For COM specifications, specify them separately.) 1 3 5 6 VZ1120MOZ-M5 Applicable valve model Rated voltage 100 VAC 50/60 Hz, 110 VAC 50/60 Hz, 24 VDC, 12 VDC Note 1) Value at manifold base mounted, single operating Note 2) Withstand voltage specification of wiring unit part is equivalent to JIS C 0704 class 1.

E A F B C D Position For transporting a workpiece to a specific position Pushing For applying force to a workpiece or for measuring the size of a workpiece E A C F B D Setting completed (Download) Step 4 Step 3 Setting of operating conditions -Entering of the operating valuesAfter the operating conditions have been set, Click the [Download] button to complete the settings.

When the IDF100F-30 is provided with options C, R and V and specified to have the ventilation direction to the right side, the part number will be IDF100F-30-CRV1. NIL IDF 100 F 30 NIL C 1 K 2 Size P 3 Air compressor size Note) 100kW 125kW 150kW Note) The value is referential. Confirm the capability of the compressor used.

MADE IN G IDF100150F i-2 i-6 IDX-OM-U021 i i-3 HFC IDF100150F i-3 i-7 IDX-OM-U021 i i-4 / 1 1.5 () IDF100150F i-4 / i-8 IDX-OM-U021 1 1 1-1 i.2.9 1 2 IDF100F-30 C.RV IDF100F-30-CRV1 IDF 100 F 30 C 1 2 G 3 K 100 125 150 ) 100kW 125kW P 150kW ) R V 30 AC200V(50Hz) AC200/220V(60Hz) 1 C 1 G 2 K 3 P R V 1-1 IDF100150F 1 1 IDX-OM-U021 1 1-2 1-2-1 (C) 1-2-2 G 1-2-3 K

Standard strokes Bore size (mm) Standard stroke (mm) Long stroke (mm) 75, 100, 125, 150, 175 350, 400, 450, 500, 600 40, 50, 63 200, 250, 300 700, 800, 900, 1000 Intermediate strokes and strokes of 75mm or less can also be manufactured.

9 High frequency quenching, Hard chrome plated Guide rod r CXTL Bearing steel Collar Aluminum alloy Clear anodized @0 Piston Aluminum alloy Chromated @1 Bearing alloy, Carbon steel Stainless steel 12 to 25 Slide bearing t Hard chromium electroplated Piston rod @2 y Ball bushing Carbon steel 32, 40 Nickel plated Carbon tool steel u C set ring Phosphate coated Type C snap ring Nickel plated

side centralized piping, switch rail C One side centralized piping, with switch rail Nil Only for MXY12 One side centralized piping, without switch rail N The auto switch cannot be mounted on the one side centralized piping type without switch rail (N).