SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2F10-75Z-B"

(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting), Made to Order Option: XC51 (w/Hose Nipple), Rod Port Location (from Rod Side): None, Head Port Location (from Rod Side): None, Hose Nipple: H4 (ø4/2.5 w/Restrictor)

(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting), Made to Order Option: XC8 (Adjustable Stroke/Extension Type Cylinder)

(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting), Made to Order Option: XC8 (Adjustable Stroke/Extension Type Cylinder)

Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.), Auto Switch Mounting Type: B (Band Mounting), Made to Order Option: XC8 (Adjustable Stroke/Extension Type Cylinder)

Magnet: Built-in, Mounting: Rod Flange, Bore: 10mm, Stroke: 125mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: Rod End Cap, Round Type, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion: Rubber Bumper, Series: J2

Magnet: Built-in Magnet, Series: J2, Mounting: Rod Flange, Bore Size: 10mm, Stroke: 30mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band

Clean Series: Vacuum Suction Type, Magnet: Built-in Magnet, Series: J2, Mounting: Rod Side Flange Style, Bore Size: 10mm, Stroke: 60mm, Cushion: Rubber Bumper, Standard, Head Cover Port Location: Perpendicular to Axis, Version: Z, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Auto Switch Mounting Type: Band Mounting

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9P, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9B, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9P, Lead Wire

Magnet: Built-in Magnet, Series: J2, Mounting: Rod Flange, Bore Size: 10mm, Stroke A: 30mm, +: None, Stroke B: None, Cushion: Air Cushion, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs.

Magnet: Built-in Magnet, Series: J2, Mounting: Rod Flange, Bore Size: 10mm, Stroke A: 60mm, +: None, Stroke B: None, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9P--Solid State, Gen.

Magnet: Built-in Magnet, Series: J2, Mounting: Rod Flange, Bore: 10mm, Stroke: 150mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9P, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9B, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9P, Lead Wire

Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes