8 201 2~200L/min 8 2 (11) S () C8 8(5/16") *6 02*1 Rc1/4 M SI*7 N02*1 NPT1/4 6 F02*1 G1/4*2 SI 1 2ISO1179-1 7:L/min :L 1 (11) L*3 3 OUT1 OU2 A NPN NPN B PNP PNP C NPN (1~5V) D NPN (4~20mA) E*4 PNP (1~5V) F*4 PNP (4~20mA) G*4 NPN *5 H*4 PNP *5 4 5 -10No.PF-OMO0004CN-E 1 W N (2 m) (2 m) + () 2 R S () () T V () () -11No.PF-OMO0004CN-E / ZS-33-D 2m ZS-33-F ZS-33-J () ZS-
-PS IDG5-N02-PS IDG10-N03-P IDG20-N03-P IDG30-N03-P IDG50-N03-P IDG60-N04-P IDG75-N04-P IDG1-N02-P The membrane air dryer uses hollow fibers composed of a macro molecular membrane through which moisture passes easily, but is difficult for air (oxygen and nitrogen) to pass through.
ID200-N02 ID300-N04 ID400-N04 ID600-N06 Series ID
For futhr delalls ol accs3sorbs, reler lo 'accssorls' on p6se 6. 4 2grtc tP300 METHOD OF OPERATION Signal pressure from a controlled pressure source enters the 1P300 input chamber and exerts a force on the diaphragms. A pressure difierential between the two diaphragms creates a force to open the pilot valve.
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. OSHA compliant, lockable soft start valve, Large effective area, Low power consumption, Modular design, SOFT START-UP VALVE, VALVE, SOFT START LOCKOUT, 241, 0.67000 lb
-02-04(S)A 4 8.2 AS22l1FG-02-06(S)A 6 10.4 23.4 32.7 (32.8) AS22l1FG-02-08(S)A 8 13.2 23.9 33.2 (33.3) 14.2 18 (19) AS22l1FG-02-10(S)A 10 15.9 26.9 36.2 (36.3) 15.6 19 (20) AS32l1FG-02-06(S)A 6 1/4 17 (17.5) 13 13.3 40 (40) AS32l1FG-02-08(S)A 8 13.2 22.7 33 14.2 41 (41) AS32l1FG-02-10(S)A 10 15.9 26.7 37 35.7 15.6 42 (42) AS32l1FG-02-12(S)A 12 18.5 29.7 40 34.5 17 43 (43) AS32l1FG-03-06(S
tighten the threaded portion by hand, then use a proper wrench, which could be Rz 12.5 suitable for the width across flats of the hexagon body, to tighten it further at a wrench For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 tightening angle shown in the table below.
tighten the threaded portion by hand, then use a proper wrench, which could be Rz 12.5 suitable for the width across flats of the hexagon body, to tighten it further at a wrench For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 tightening angle shown in the table below.
tighten the threaded portion by hand, then use a proper wrench, which could be Rz 12.5 suitable for the width across flats of the hexagon body, to tighten it further at a wrench For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 tightening angle shown in the table below.
A ridge shape has been created as a Uni thread for common applications for Rc, G, NPT and NPTF. AS-FM Note) Universal type is not available.
tighten the threaded portion by hand, then use a proper wrench, which could be Rz 12.5 suitable for the width across flats of the hexagon body, to tighten it further at a wrench For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 tightening angle shown in the table below.
Piston assembly Valve Valve spring No. 4 5 6 1348104A 1348105 1348109 SUP OUT 2 ARX Series Specialty Regulators Regulator for 290 psi (2 MPa) ARX20, 21 Dimensions Panel cutout dimensions 1.02 (26) R .1 (2.5) SUP OUT SMC K C O P A A L U S H .5 (12) 1.61, 2.13 [41 (K40)], [49 (K50)] 2.13 (54) .98 (25) 1.6 (max. thickness 4.5) 1.73 (44) .21 (5.4) 3.13 (79.5) (when regulating pressure = 3.23
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. OSHA compliant, lockable soft start valve, Large effective area, Low power consumption, Modular design, SOFT START-UP VALVE, VALVE, SOFT START LOCKOUT, 241, 0.67000 lb
/4 ASV410F-N02 14 13.5 NPT 3/8 ASV410F-N03 14 13.5 NPT 1/4 ASV510F-N02 27 23 NPT 3/8 ASV510F-N03 29 27 JIS Symbol NPT 1/2 ASV510F-N04 29 27 Specifications Series ASV120F ASV220F ASV310F/410F ASV510F Air Fluid 1.5 MPa Proof pressure 1 MPa Max. operating pressure 0.1 MPa Min. operating pressure Ambient and fluid temperature Number of needle rotations 10 turns 8 turns 12 turns 15 turns Applicable
Body Size: 2000, Thread: N (NPT), Port Size: 02 (1/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)
Body Size: 2000, Thread: N (NPT), Port Size: 02 (1/4), Option: None, Voltage: 3 [110 VAC (115 VAC)], Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)
Body Size: 2000, Thread: N (NPT), Port Size: 02 (1/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: G (Grommet, Lead Wire Length: 300mm), Surge Suppressor: None, Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)
Body Size: 2000, Thread: N (NPT), Port Size: 02 (1/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: G (Grommet, Lead Wire Length: 300mm), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)
Body Size: 2000, Thread: N (NPT), Port Size: 02 (1/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: G (Grommet, Lead Wire Length: 300mm), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)
Body Size: 2000, Thread: N (NPT), Port Size: 02 (1/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)