Use caution, as there is a danger of being burned if a valve is touched directly. 2. Valves may reach high temperatures when continuously energized. Use caution, as there is a danger of being burned if a valve is touched directly. SOL. AC AC SOL. Without light AC SOL.

Conduit terminal: VP3145-T A B DIN terminal: VP3145-D A B [105] 76 Light (For TL, TZ) 30 31.3 Max.12 G1/2 Applicable cable 6 to 12 Light position (For DL, DZ) G1/2 [196] NO NO 190.6 194 181.5 166 PE PE 26 26 83 83 32 32 36 36 80 80 [ ]: With indicator light (TL, TZ) 1310 Large Size 3 Port Solenoid Valve VP3165 Series Dimensions: VP3165 Grommet: VP3165-G A B 113 87.4 54 30 71 101 G1/2 1

Ht A 33 B G 1/2 (applicable cable O.D. 6.8 to 9.6) Approx. Hs Reed switch D-A3 Solid state switches D-G39, D-K39 56 56 34 36 B A 49 Auto switch G 1/2 (applicable cable O.D. 6.8 to 9.6) Approx. Hs Reed switch D-A44 36 B Auto switch D-A4 49 A Approx.

OUT 1 Thread type Rc NPT NPTF G Nil N T F IN Voltage 1 2 3 4 5 6 36 100VAC 200VAC 110VAC 220VAC 24VDC 12VDC 230VAC Port size Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Symbol 01 02 03 04 06 Class 4 Class B with AC has a built-in rectifying circuit. Class H is AC only. Without rectifying circuit. Contact P/A regarding other voltages.

If touched inadvertently, there is a danger of being burned.

A void A void A void A void A void A B A B A B A B A B A A A B A B A B A A A A 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 15 0 0 1 2 3 4 5 SC type OMRON SYSBUS wire system compatible SD type Sharp Satellite I/O link system compatible Terminal block (LED) nomenclature ADDRESS NO. STATION NO.

A void A void A void A void A void A B A B A B A B A B A A A B A B A B A A A A 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 15 0 0 1 2 3 4 5 SC type OMRON SYSBUS wire system compatible SD type Sharp Satellite I/O link system compatible Terminal block (LED) nomenclature ADDRESS NO. STATION NO.

13 157 149 14 167.5 159.5 15 178 170 16 188.5 180.5 17 199 191 18 209.5 201.5 19 220 212 4-4-15 16 Series SYJ300 Type 20R Manifold: Top Ported (External Pilot Type)/SS3YJ3-20RStations -00 [ ] for AC Grommet (G) L3 8 12 M5 x 0.8 (X port) 8.5 2 17.5 11.5 5 5 X X X X X 20.5 17 X X Approx. 300 (Lead wire length) 30.7 P R 52.9 [55.1] 36 A A A A A 2-4.5 (For mounting) 1/8 (P, R port) M3 x 0.5

Operating principle A + A' A' A Piston seal A' A' R H R H When the piston is retracting, air is exhausted through both A and A' until piston seal H passes air passage A. After piston seal H has passed air passage A, air is exhausted only through A'. The section marked with slanted lines becomes a cushion chamber, and an air cushion effect is achieved.

Installation at indoor site 1 In case of facility having a large installation area (that can vent the air naturally) Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2 In case of facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air

A B A B A Void A Void A B A B A B A A A B Double Double Double Double Double SY Sl unit Sl unit Single Single Single Single Single SYJ Stations Stations 1 2 3 4 5 1 2 3 4 5 Single/Double mixed wiring (Option) Double wiring (Standard) SX SC applicable to SYSBUS Wire System (OMRON) SD applicable to Satellite I/O Link System (Sharp) VK VZ ADDRESS NO. STATION NO.

SI unit output No. 0 1 2 3 4 5 6 7 8 9 SI unit output No. 0 1 2 3 4 5 6 7 A B A B B A Void A Void A A B A B B A A A SY Double Double Double Double Double SI unit SI unit Single Single Single Single Single SYJ Stations 1 2 3 4 5 Stations 1 2 3 4 5 Single/Double mixed wiring (Option) Double wiring (Standard) SX SC applicable to SYSBUS Wire System (OMRON) SD applicable to Satellite I/O Link

Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.

Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.

Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.

Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.

Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.

PC-AT 3m 36) LE-CSNS 10120-3000PE 10320-52F0-008 (3M) 11 5 11 11.1.2 (1) LE-CSE-ALE-CSE-B LE-2m 5m 10m LE-CSE-SA 2 5 A IP65 LE-LE-CSE-RA 2 5 A IP65 LE-CSE-SB 2 5 A IP65 LE-LE-CSE-RB 2 5 A IP65 (a) LE-CSE-SA LE-CSE-RA MR-J3ENCBLM-A1-L MR-J3ENCBLM-A1-H HF-MP HF-KP LE-LE-CSE-SB LE-CSE-RB MR-J3ENCBLM-A2-L MR-J3ENCBLM-A2-H HF-MP HF-KP CN2 CN2 36210-0100PL 36310-3200-008 (3M) 54599

"~ =~~P~a'~-t -, .~.@. Deteriorated Pad 36 Vacuum Pad/Components VacuumPad/Components Part/ Pad(With Lock Ring) Flat type pad Flat type pad with rib ZPlOCO-5OCO ZP02UO 08UO .0 oC (mm, ' , 19.5 3,e I C 'A . t El' K; 11'0 E ' Part No.