SMC Corporation of America
Elite Part Number Search
Search Results "AL30-03-38-A"

A A A A 19 2 MAX.5 10 10 (Lead wire length) G : About 300 H : About 600 24.5 (Pitch) P=10.5 10.5 (Mounting holes) L2 4 L1 (Non-locking) Manual override A A 20 48.5 [55] 15 B B 5 36.1 1.5 29.5 A A (Pitch) P=10.5 17.5 2n-One-touch fitting (A, B port) 20 15 B B 5 1.5 2n-M5 0.8 (A, B port) (Pitch) P=10.5 15.7 Other dimensions are the same as the M5T.

Type S3: Side ported (Lead wire length) 91.7[96.1] Approx. 300 10-SS5YJ3-S31Stations -M3 L1 3.5 L2 2-3.5 (For mounting) Manual override M5 x 0.8 (P, R port) 5.2 29.2 7.5 17.3 30 52.2[54.4] 51.4[53.6] 3 91.7[96.1] 78.8[83.2] 78.8[83.2] A A A A A 13.5 B B B B B P R P R P R 29.2 P R 30 17.3 25 7.5 12 25 51.4[53.6] 52.2[54.4] 13.5 B B B B B A A A A A 3 5.2 2-3.5 (For mounting) Manual override

VQZ (A) 2 (A) 2 VZ 3 (R) 1 (P) 3 (R) 1 (P) VS VFN r e w q r e w q N.O. N.O. (A) 2 (A) 2 3 (R) 1 (P) 3 (R) 1 (P) Component Parts No.

When a system hazard can be expected due to a drop in vacuum pressure caused by power loss or vacuum pump trouble, install a safety circuit and configure the system so that it can avoid the danger. 2. When a system hazard can be expected with a malfunction of the vacuum regulator, install a safety circuit and configure the system so that it can avoid the danger. 1.

When a surge generating a load such as a relay or solenoid is directly driven, use a type of switch with a built-in surge absorbing element. 4. Since the type of fluid varies depending on the product, be sure to verify the specifications. The switches do not have an explosion proof rating. To prevent a possible fire hazard, do not use with flammable gases or fluids. 5.

Applicable mounting bracket Bore size (mm) Joint 55 6 18 56 YA-03 32, 40 A type mounting bracket B type mounting bracket 100 8 22 67 YA-05 50 YA-03 YB-03 32, 40 YU-03 YA-05 YB-05 50 YU-05 B type mounting bracket Allowable eccentricity mm Bore size 32 40 50 1 Eccentricity tolerance 0.5 Backlash Joints are not included with A type and B type mounting brackets.

Aluminum alloy 1728 3 Port 3 Position Valve VEX3 Series Working Principle Fig. (1) A R Fig. (2) Closed center Fig. (3) P A 3(R) 3(R) 3(R) 2(A) 2(A) 2(A) 1(P) 1(P) 1(P) This is a 3-port switch valve in which the shaft 7 extending from the driving piston 3 opens/closes a pair of poppet valves 6.

size (mm) MM A NN D F G1 G2 S ZZ I H J N1 N2 NA TN TF 10 15 M12 x 1 4 M5 x 0.8 8 15 6 M4 x 0.7 65 101 18.5 28 16 11 20 16 16 15 M14 x 1 5 M5 x 0.8 10 15 6 M5 x 0.8 74 114 22 30 22 12 21 19.5 20 18 M20 x 1.5 8 Rc1/8 13 NPT1/8 25 G1/8 8.5 M8 x 1.25 97.5 151 31.5 40.5 28.5 20.5 33 29 25 M10 x 1.25 18 M26 x 1.5 10 Rc1/8 13 NPT1/8 30 G1/8 8.5 102.5 160 34.5 44.5 32 20.5 38 32 Refer to page

When a surge generating a load such as a relay or solenoid is directly driven, use a type of switch with a built-in surge absorbing element. 4. Since the type of fluid varies depending on the product, be sure to verify the specifications. The switches do not have an explosion proof rating. To prevent a possible fire hazard, do not use with flammable gases or fluids. 5.

0.31 0.31 0.30 0.33 b 0.34 0.47 0.51 0.34 0.47 0.51 0.34 0.44 0.48 0.33 0.48 0.53 Cv 1.0 1.2 1.4 1.0 1.2 1.4 1.0 1.2 1.3 1.1 1.2 1.3 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 8 Rc VSA4120-01 VSA4120-02 VSA4120-03 VSA4220-01 VSA4220-02 VSA4220-03 VSA4320-01 VSA4320-02 VSA4320-03 VSA4420-01 VSA4420-02 VSA4420-03 2 position single VA 1 4 1 8 Rc 0.60 1 8 Rc 1 8 Rc SA 2 position double

1 E-P HYREG Series VY1 A hybrid regulator is created from a regulator and a solenoid valve F.R.L. AV AU Stepless control through electric signals AF A maximum effective area of 670 mm2 (2B) can be covered by the combination of an ultra-compact electro-pneumatic pilot valve (22.4 x 30 x 39) and a 3 port, high-capacity exhaust main regulator (Series VEX100).

A y OUT 2 I N 1 SMC A t e IN OUT r q w Parts list Material Note Description No.

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

CE-compliant Valve mounting direction Stations R port Nil Pilot valve is opposite the A port side. 02 2 stations A A M5 x 0.8 Nil R port P R Q CE-compliant : : A A M5 x 0.8 A port M3 x 0.5 P port M5 x 0.8 Pilot valve is on the A port side. 20 S 20 stations P port M5 x 0.8 A port M3 x 0.5 Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of

Although the circuit at the output side of the switch is surgeprotected, damage may still occur if a voltage surge is applied repeatedly. When a load which generates a surge, such as from a relay or solenoid valve, is directly driven, use a switch with a built-in surge absorbing element. 4. Since the type of fluid varies depending on the product, be sure to verify the specifications.

Note 4) AS231FE-01 (4, 6) is POM. 15-9-38 4 Speed Controller with Residual Pressure Release Valve with One-touch Fitting, Elbow Type/Universal Type Dimensions Elbow type Model Weight (g) T H1 H2 D1 D2 L1 L2 L3 L4 A M1 Max. Min. Max. Min.