S. l AR2001 2501 3001 : Max.3.5t :-t-tt ., AR4001 : Max.5.0t ~ I II; a -tp ort cenler (fJ ~ ~c=Pr r-IN j~ OUT f= 0 .bj=J ~ A * N P Q Bracket mounting dimensions Model Port size A B C 0 E F G H J K L M AR2001 1/8 1/4 40 95 17 40 35 30 34 44 5.4 15.4 55 2.3 33.5 25 8 33 AR2501 1/4 3/8 53 102.5 25 48 32 30 34 44 5.4 15.4 55 2.3 33.5 25 843 42.5 32.5
m AFJ20-02-40-S/AFJ30-03-40-S/AFJ40-04-40-S AFJ20-02-40-T/AFJ30-03-40-T/AFJ40-04-40-T 12 12 AFJ20-02-40-T AFJ30-03-40-T AFJ20-02-40-S AFJ30-03-40-S AFJ40-04-40-S 10 10 Pressure drop [kPa] Pressure drop [kPa] 8 8 AFJ40-04-40-T 6 6 4 4 2 2 Water drop removal type Nominal filtration rating: 40 m Large flow type Nominal filtration rating: 40 m 0 0 0 100 200 300 400 500 600 800 700 900 Flow rate
2 3 4 5 6 7 8 9 10 Flow rate (slpm, N2) 4.34 (110.2) Hastelloy is a registered trademark of Haynes International.
2(A) 2(A) 47.5 VHS 13.5 (A port) Rc 3/8 Individual exhaust: VV3PA5-42Station 3-03 28.5 3(R) 3(R) (R port) Rc 3/8 PA NO NC 87 (PA port) Rc 1/8 (Mounting hole) 2-7.2 30 PA 41.5 91.4 84.4 91.4 60 16.5 1(P) 41.5 PA (P port) Rc 3/8 (Pitch) 88 31 33 7.5 L2 L1 (PA port) Rc 1/8 PA 61.5 66 2(A) 2(A) 47.5 13.5 (A port) Rc 3/8 n: Station n L L1 L2 Formula L1 = 33 x n + 29 L2 = 33 x n + 14 6 227 212
NPT thread Model Model 10-32 UNF M5 3/8 1/8 1/4 1/2 3/8 1/8 1/4 1/2 AKH04 AKH06 AKH08 AKH10 AKH12 AKH03 AKH07 AKH09 AKH11 AKH13 4 6 8 10 12 5/32 1/4 5/16 3/8 1/2 From One-touch fitting to male thread B Bushing type AKB 01 A 01 S With seal (Standard) Body size Port size 01 1/8 01 1/8 Thread type 02 1/4 02 1/4 03 3/8 Nil R 03 3/8 04 1/2 N NPT 04 1/2 Check valve free flow direction Female/Male
Therefore, use a separate wiring route for this product. 8. Confirm that the wiring is correct before operation. 8. Do not apply moment to the nozzle. A moment force may be applied to the nozzle depending on the shape of the nozzle attached to the female piping thread. It is possible that the nozzle or ionizer body will be damaged if vibration occurs.
B A B A B A B A B A B A B A B A B A B A B Bore size 40 50 63 80 100 6 4 3.5 1.5 6 3 1 0 0.5 6.5 2 4 11.5 10 3 0 0 4.5 0 2 9.5 8 3.5 1.5 5.5 3 1 0 0.5 6.5 2 4 11.5 10 3.5 0 0 4.5 0 2 9.5 8 8.5 7.5 6 5 3 5.5 4 2.5 3 9 4.5 6.5 14 12.5 1.5 1.5 2 8 3.5 5.5 13 11.5 12 10 9.5 7.5 6 9 7 6 6.5 4.5 8 10 17.5 16 4.5 4 4.5 12.5 6 8 15.5 14 13.5 12.5 11 10 8 10.5 9 7.5 8 14 9.5 11.5 19 17.5 6.5 6.5
Valve (Port size) VQ 1 (1.5mm) 2 (2.2mm) 3 (3mm) 4 (4mm) VXA31 VXA32 01 ( ) 1 8 02 ( ) 1 4 03 ( ) 3 8 02 ( ) 1 4 Ordering Example (Example) Series VXA31, Orifice size 1.5mm, Rc(PT)1/8 (Part number) VXA3114-01 4.1-69 VXA31/32 Air How to Read the Graph In the sonic flow region: For a flow of 100 l/min.
(port B) Manual override R1 R2 P A B 14 11 9 50 62 38 50 62 A 12 Prewired connector (M12) (L approx. 500) R1 P R2 A B 13 13 2-Rc1/8 2-6.5 Mounting hole Indicator light 42.5 42.5 3-Rc1/4, 3/8 (P, A, B) 34 34 Bottom port drawing SMC (ports A, B) 93 12 Y 25 (port X) 5 3 37 22 14 25 14 1 25 9 25 2-Rc3/8 Ports R1, R2 Rc1/4, 3/8 Port P Rc1/8 Port Y (PE) 2-Rc1/4, 3/8 Ports A, B Rc1/8 Port X (PE
7 Oil-impregnated sintered alloy Urethane 40 or larger: Lead-bronze casted Bushing t Urethane Cushion seal A !8 NCM Bumper A y Urethane Cushion seal B !
Connector wiring diagram (mixed wiring) Connector type manifold 6 A 4 A 3 A 1 A 5 B 2 B Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing
The AL bowl (size 30 and 40) is covered with a transparent bowl guard, allowing 360 monitoring.?The oil drop rate is adjustable depending on equipment requirements. The AL modular design allows connection with other SMC air preparation equipment. AL MASS PRO. LUBRICATOR. AIRLINE EQUIPMENT. AL MASS PRO 1/4 MODULAR (PT). 1.58065 lb. DA.
Y: 4.5 to 7 D: 6 to 8 78.3 2(A) 2(A) 63 19 (A port) Rc1/2 Stations L L1 L2 Formula L1 = 41 x n + 33 L2 = 41 x n + 17 9 402 386 10 443 427 2 115 99 3 156 140 4 197 181 5 238 222 6 279 263 7 320 304 8 361 345 : With light/surge voltage suppressor ( ): Dimensions for external pilot 4-8-15
H2 L3 L2 L1 All Ports: Screw-in Model H1 H2 H3 L1 L2 L3 L4 Connection thread 1 Connection thread 2 Connection thread 3 ZH05DA-01-01-01 12 12 12 67 42.5 27 26 Rc1/8 Rc1/8 Rc1/8 ZH07DA-01-01-01 70.2 ZH10DA-01-01-01 76.4 ZH13DA-01-02-02 17 17 90.8 51 29.5 36.3 Rc1/4 Rc1/4 ZH15DA-02-03-03 17 19 19 108.2 63.3 34.3 37.1 Rc1/4 Rc3/8 Rc3/8 ZH18DA-03-03-03 19 131.1 73.6 41.1 39.1 Rc3/8 ZH20DA-03-04
(mm) Elbow type TMH 6 8 10 12 Tube swivels 360 AS121F-M5-W2 M5 ASD Application to inch size tubing Metric size 6, 8, 10, 12 AS221F-01-W2 R1/8 AS221F-02-W2 R1/4 AS AS321F-02-W2 R1/4 Maximum operating pressure 1 MPa max.
Handle operated type Air operated type VBA1110 VBA200 VBA400 Model AV Max. 2 Pressure increase ratio VBA2200-03 VBA4200-04 VBA1110-02 VBA1-02 VBA2100-03 VBA4100-04 Note) 400 60 1000 1900 1000 1900 Max. flow (l/min (ANR)) VBA1 2 to 4 AU 1/2 (IN/OUT) 1/4 (IN/OUT) Connection port size Rc 3/8 (IN/OUT) 3/8 (IN/OUT) 1/2 (IN/OUT) Fluid Compressed air 1/4 Exhaust port size Rc 3/8 1/2 1/2 3/8 VBA1110
Note Bracket A ZS-46-A1 Tapping screw: Nominal size 3 x 8 L (2 pcs.) Bracket B ZS-46-A2 Tapping screw: Nominal size 3 x 8 L (2 pcs.)
(mm) 04 06 08 10 12 Type 4 6 8 10 12 Port size Elbow Universal 2 3 01 02 03 04 R 1/8 R 1/4 R 3/8 R 1/2 Control type Meter-out Meter-in 0 1 With residual pressure release valve With One-touch fitting 15-9-36 2 Speed Controller with Residual Pressure Release Valve with One-touch Fitting, Elbow Type/Universal Type Needle Valve/Flow Characteristics AS2201FE-02, AS2211FE-02 AS2301FE-02, AS2311FE
Cv 1.9 2.2 1.9 2.2 1.6 1.7 2.0 (0.96) 2.4 (0.96) 1.5 1.7 VFRA3111-02 VFRA3111-03 VFRA3211-02 VFRA3211-03 VFRA3311-02 VFRA3311-03 VFRA3411-02 VFRA3411-03 VFRA3511-02 VFRA3511-03 1/4 3/8 1/4 3/8 1/4 3/8 1/4 3/8 1/4 3/8 0.38 0.39 0.41 0.36 0.40 0.39 0.42 0.42 0.33 (0.48) 0.34 (0.47) 1.9 2.2 1.9 2.0 1.8 1.9 1.7 1.8 1.9 (0.69) 2.2 (0.69) 0.61 Single 1/8 2 position 0.71 Double 1/8 Body ported Closed
When a load, such as a relay or solenoid valve, that generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.