LECSB Positioning unit QD75D (Manufactured by Mitsubishi Electric) 24 VDC Note 2) Note 4) CN1 Note 4) 21 DICOM CN1 Failure Note 3) DICOM 20 48 ALM RA1 CLEARCOM 14 DOCOM 46 Zero speed detection 23 ZSP RA2 CLEAR 13 CR 41 Torque limiting RDYCOM 12 25 TLC RA3 Positioning completion READY 11 RD 49 24 INP RA4 PULSE F+ 15 PP 10 PULSE F 16 PG 11 10 m or less NP 35 17 PULSE R+ S/S NG 36 4 LA 18 PULSE
CC RB J D-X 20Data 10-12-11 11 Series CEP1 Dimensions: 12 Direct mounting, rod side tapped style: CEP1B12 Stroke 4 depth 4 (Positioning pin hole) Cable end + 0.05 + 0.02 17 40 4 depth 4 Without connector + 0.05 + 0.02 (Positioning pin hole) 4 45 4-M5 x 0.8 Thread depth 10 6 Metal connector M14 x 1 4-M5 x 0.8 depth 6 (Bottom 4.3 through-hole) 7.5 counterbore depth 4 (500 or 3000) 25 70 0.5
Bore size (mm) Stroke (mm) Bore size (mm) Manufacturable stroke range Applicable auto switch Note D25 50 100 75 125 150 175 200 250 300 400 500 12 25 to 150 D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-F7V D-F7/J79 D-J79C D-F7WV D-F7W/J79W D-F7BAL/F7BAVL D-F79F/F7NTL Switch mounting screw (M3 x 0.5 x 8l ) Square nut 12 20 -X BQ-1 20 25 to 300 32 2025 to 400 40 25 to 600 32 40 50 63 Switch
260 400 250 1200 1050 1200 1060 500 360 500 350 600 460 600 450 Dimensions inside ( ) are for a 100 mm stroke.
L3 [mm] L3 [mm] L3 [mm] m 600 600 600 L3 Z 400 400 400 200 200 200 0 0 0 0 10 20 30 40 50 60 70 0 10 20 30 40 50 0 5 10 15 20 25 30 35 Work load [kg] Work load [kg] Work load [kg] 1000 1000 1000 800 800 800 L4 [mm] L4 [mm] L4 [mm] 600 600 600 L4 X 400 400 400 200 200 200 0 0 0 0 10 20 30 40 50 0 10 20 30 40 50 60 70 0 5 10 15 20 25 30 35 Work load [kg] Work load [kg] Work load [kg] 1000
Blue (DC COM) 11 Terminal No. Black (Output 1) 3 Terminal No. Black (Output 1) Fig. 3-10 Wiring of the external switch (NPN open collector output) (example) Flow switch Blue (DC COM) Brown (24 VDC) Brown (24 VDC) Terminal No. 14 Terminal No. 6 Flow switch Blue (DC COM) Terminal No. 13 Terminal No. 3 Black (Output 1) Black (Output 1) 11 Terminal No.
Metric size Inch size With One-touch fitting 04 06 08 10 12 01 03 05 07 09 11 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT AS N ASP Bore size ASN M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AQ ASV AK ASS Needle Valve/Flow Characteristics (Inlet Pressure: 0.5 MPa) ASR ASD230F ASD330F ASD430F ASF 100 200 400 1.5
Centigrade(oC) Fahrenheit(oF) 5.13 11 Changing temp. unit Pressure unit can be changed.
154 55 11 134 130 102 139 58 9 XLC-160 138 339 200 65 11 190 180 153 124 62 12.5 10 XL-OMV0002 5. 200 1680 100 100,160[ ]18 12 Assy O XLC-16,XLC-25,XLC-40,XLC-50,XLC-63,XLC-8 200 XLC-100,XLC-160 100 FKM 110 Pa 11 XL-OMV0002 . 6-1. 1 1 Assy Assy Assy 12 XL-OMV0002 6-2. 1 2 3 3 2 1 4 162540 50,63,80,100,160 O O O O 50 4 5 6 3 3 2 1 4 2 1 Nm 4 0.7 XLC-16 1.5 -25 2.5 -40 6 -50 6
55 41 63 XLF-50 70 170 79 2 11 75 52 68 XLF-63 88 196 100 3 11 87 95 70 69 XLF-80 90 235 117 3 11 114 110 83 96 XLF-100 108 300 154 3 11 134 130 102 131 XLF-160 138 315 200 3 11 190 180 153 112 9 XL*-OMJ0003-D 5.
Requires set up software(MR Configurator2TM) . -11- 3. Wiring 3.1 Power Supply Wiring Connect the actuator and driver power supply. (1) LECSC (Absolute encoder) EX.)
However, for 400 VAC, model should also be selected based on the amount of processed air of 380 VAC regarding IDFA100F to 150F. (Correction factor is based on the rated conditions of 380 VAC, so when the factor of rated conditions of 400 VAC is inputted , the amount of processed air of 400 VAC can be found.)
Pipe thread type Note 1) 400 V type is provided with an earth leakage breaker with handle (-B1) as standard.
IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option.
MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 11 17 19 21 0.3 RHC G 7 11 13 13 0.5 10 10 50 100 200 300 400 (mm/s) (Initial cushioning speed) 4 7 9 9 0.7 500 MK(2) Rod side trunnion style: U Head side trunnion style: T 32 42 48 52 0.3 Clevis style: C, D RS
(Manufacturable stroke range: LEJS63-M/ 790 to 1790mm) Note13) The return to origin of stopper type can not be used. 15 - Product Weight Series LEJS40 Stroke [mm] 200 300 400 500 600 700 800 900 1000 1200 Weight (kg) 5.6 6.4 7.1 7.9 8.7 9.4 10.2 11.0 11.7 13.3 Extra weight of lock (kg) S2:0.2 / S6:0.3 / T6:0.2 Series LEJS63 Stroke [mm] 300 400 500 600 700 800 900 1000 1200 1500 Weight (kg
Note 2) 400 V type is provided with an earth leakage breaker -B as standard.
Refer to Table 5-11. Make a selection with the [] [] keys and press the [SEL] key to apply the setting.
DATA OUT 1 2 3 SET 1 2 SET MONOSASHI-KUN AC100V OUT1 COM OUT2 COM COM OUT3 Series Guide Series CE1 Bore size (mm) Available stroke range Standard stroke (mm) Series CEP1 Standard stroke (mm) Bore size (mm) 12 equiv. 250 400 500 300 175 200 150 125 100 75 50 100 25 75 50 25 12 25 to 150 20 equiv. 20 25 to 300 32 25 to 400 40 25 to 600 50 25 to 600 63 25 to 600 CEU1 CEU5 Output transistor system
Part No. 25 350, 400, 450, 500 75, 100, 125, 150, (Band and screw are included.) 32 350, 400, 450, 500, 600 Ball bushing bearing MLGCL 200, 250, 300 Bore size (mm) Auto switch model D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 40 350, 400, 450, 500, 600, 700, 800 20 25 32 40 BMA2 -020 BA -01 BA -02 BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other