SMC Corporation of America
Elite Part Number Search
Search Results "11-CDM2XB40-300-H7A2"

(N) 100, 200, 300, 400, 500 15 750 1 axis Operating pressure (MPa) Piston area (mm2) 100, 200, 300, 400, 500, 600 20 Bore size (mm) 1000 0.3 0.2 0.4 0.5 0.6 0.7 100, 200, 300, 400, 500, 600, 800 25 1200 10 15 23 78 31 39 54 46 100, 200, 300, 400, 500, 600, 800, 1000 25 2 axis 15 35 52 176 70 88 123 105 1500 32 20 62 94 314 125 157 219 188 Note) Strokes are manufacturable in 1 mm increments

400 500 1000 1500 0.05 0.5 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 Technical Data Piston speed (mm/s) Piston speed (mm/s) Piston speed (mm/s) Piston speed (mm/s) 1349 Mechanically Jointed Rodless Cylinder with Protective Cover Slide Bearing Guide Type, Cam Follower Guide Type MY1W Series 16, 20, 25, 32, 40, 50, 63 How to Order MY1 M W K 300

Station 9 SOL.B 22 SOL.A 10 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors Station 10 SOL.B 23 SOL.A 11 Station 11 SOL.B 24 SOL.A 12 Station 12 SOL.B 25 Note) COM. 13 Positive COM spec. Negative COM spec. 1021-VV5Q21 The total number of stations is tabulated starting from station one on the D-side.

Station 9 SOL.B 22 SOL.A 10 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors Station 10 SOL.B 23 SOL.A 11 Station 11 SOL.B 24 SOL.A 12 Station 12 SOL.B 25 Note) COM. 13 Positive COM spec. Negative COM spec. 1021-VV5Q21 The total number of stations is tabulated starting from station one on the D-side.

Note 2) For manifold dimensions including elbow fitting, see page 11.

20 8 60 80 Size 60 2 1 191.2 45 93.1 30 45 70 50 70 11 20 8 60 80 Number of components Model Combination example r A N F J M Pressure Relief 3-port Valve VHS30-03-D 1 pc.

Station n L1 L2 Station 2 66 46 Station 20 408 388 3 85 65 4 104 84 5 123 103 6 142 122 7 161 141 8 180 160 9 199 179 10 218 198 11 237 217 12 256 236 13 275 255 14 294 274 15 313 293 16 332 312 17 351 331 18 370 350 19 389 369 63 Series SYJ7000 Type 40: Bottom Ported/SS5YJ7-40Stations -01 [ ]: AC Approx. 300 (Lead wire length) Grommet (G) L1 L2 4-4.5 (For mounting) 10 1.5 (DIN 2.8) 15.3

Bar length [mm] IZN10-G-100-X226 100 IZN10-G-200-X226 200 IZN10-G-300-X226 300 IZN10-G-400-X226 400 IZN10-G-500-X226 500 IZN10-G-600-X226 600 Part no.

(High pressure warning label position at 300 mm length) 19.6 25 80 x (n-1) 70 10 25 Emitter cartridge n (Number of emitter cartridges), L Dimension L(mm) 300 380 620 780 1100 1260 1500 1900 2300 n Part no. 3 4 7 9 13 15 18 23 28 (Name plate position at 300 mm length) IZS31-300 IZS31-380 IZS31-620 IZS31-780 IZS31-1100 IZS31-1260 IZS31-1500 IZS31-1900 IZS31-2300 660 A Ionizer Series IZS31 Dimensions

2 16 Step motor (Servo/24 VDC) 392 Electric Actuator Miniature Slide Table Type LEPS Series Step Motor (Servo/24 VDC) Dimensions LEPS6 D C B A 3.5 4 5.2 LEF 19 LEJ LEL ( ) +0.025 0 ( ) +0.025 0 2.5H9 depth 2.5 2.5H9 depth 2.5 2 x M4 x 0.7 thread depth 8 LEM LEY 4 x M4 x 0.7 thread depth 6 20 11 19 LES J 25 11 LEPY LEPS LEPY LEPS LER Table operating range Note 1) LEH Motor cable length 300

-1/8 (OUT port) 11 P = 22 11 1.5 4.5 6 32 6 54 ( 19.5) 11 9.5 11 9.5 4-M4 x 0.7 10 24 10 46 When not equipped with bracket, the M3 threads at both ends (4 positions) can be used for other purposes.

dia 1.6 Cross section 0.34mm2 VP VG 59 PE port R 3 1 P (30) VP 25.5 11 M5 X 0.8 External pilot port (Only external pilot style (R)) 2-Rc(PT)1/4 P(SUP)port 20 12.5 38.5 2-Rc(PT)1/4 R(EXH)port VQ The broken line indicates DIN rail mounted style [-D]. 43.5 11 VQZ L plug connector (L) DIN terminal (Y) VZ 300 (Lead wire) 86(87) VS 83(84) 90 MAX.10 61(64.5) 87 Pg.7 Cover dia 1.5 Cross section

(12B) 760 D 795 150 E 300 270 F 520 1033 G 1318 3 H 3 887 J 620 AMD801/811 AMD91 972 AMD800/810/90/100 ORIENTATION IN OUT 3 x H holes IN OUT Label Drain (mm) Model 500 A 300 B 200(8B) C 300 D 1300 E 1430 F 1520 G 20 H Connection (Flange) 50(2B), 80(3B)JIS 10K FF flange 50(2B), 80(3B), 100(4B)JIS 10K FF flange 100(4B), 150(6B)JIS 10K FF flange 870 M20 x l500 AMD100 720 M16 x l400 Anchor bolt

11 11 D-A59W 13 13 13 14 14 15 D-A3, A44 9 9 10 11 11 11 10 D-Y59, Y69 D-Y7P, Y7V D-Y7W, Y7WV 7 5.5 5.5 7 7.5 6.5 5.5 D-Y7BAL 6 3.5 3.5 3.5 4 4.5 5 D-F5, J5 D-F5W, J59W D-F5BAL, F5NTL D-F59F 3.5 4 4 4.5 4.5 4.5 5 5.5 5.5 6 6 6 D-F5LF 5 9 4 9 4 9 4 10 4.5 10 4 11 6 D-G39, K39 11 D-P5DWL 4.5 4.5 These values are given as guidelines including the hysteresis and are not guaranteed.

Supply valve Circuit diagram (300) 67 [69.2]1 Manual override Specific Product Precautions 35 (175) 28.6 [35.6]1 7.7 214 [221]1 185.8 *1 [ ] for AC * Tighten to the recommended torque on pages 10 and 11 to mount the body.

Selectable option for manifold (Refer to i on pages 11 and 12, and y on page 13.)

500 400 300 L-unit Air cushion 200 200 Caution 1002 3 4 5 10 20 50 100 1 2 3 4 5 10 20 30 400 50 1.

T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.

VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 Nozzle size 2.5 3 3.5 2.5 3 3.5 2.5 3 3.5 2.5 3 3.5 01 02 03 04 05 06 07 11 12 13 21 22 23 24 31 32 33 34 35 36 37 38 41 42 43 44 45 46 47 48 49 50 51 52 23.4 23 22.5 22.1 22 Nozzle length: 100 mm 98