Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, CYLINDER, ROTARY CLAMP, CLAMP CYLINDER, 999 lb

Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, Cylinder, Rotary Clamp, CLAMP CYLINDER, 1.3 lb

/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ008-H1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol20 to 908.0 (at 20C)3.0 (at 20C)?

/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ001-L1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?

/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ002-L1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?

/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ002-L1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?

/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ002-W1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?

/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ008-H1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol20 to 908.0 (at 20C)3.0 (at 20C)?

/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ008-L1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?

/60 Hz) (l/min)Power supplyBreaker capacityRated currentAlarmCommunications( C)(MPa)(A)(kg)HRZ010-WSWater-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35 C, Humidity: 30 to 70%RH?

1Voltage input (12 VDC or 24 VDC)10.8 to 13.2 VDC, 60 mAPreset output, Cylinder stop outputCompare/Hold/One-shot (100 ms fixed pulse)Separate 5 point output/Binary code output5 ms or less (for normal output)RS-232CPNP open collector Max 30 VDC, 50 mA90 to 264 VAC20 VA or lessBetween case and AC line: 1500 VAC for 1 min.

/60 Hz) (l/min)Power supplyBreaker capacityRated currentAlarmCommunications( C)(MPa)(A)(kg)HRZ010-W2SWater-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35 C, Humidity: 30 to 70%RHClear water, Deionozed water10 to 609(at 20 C)2.5 (at 20 C)?

Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, Cylinder, Rotary Clamp, CLAMP CYLINDER, C70, 1271 lb

Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, Cylinder, Rotary Clamp, CLAMP CYLINDER, C70, 1540 lb

Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, Cylinder, Rotary Clamp, CLAMP CYLINDER, C70, 1324 lb

Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, Cylinder, Rotary Clamp, CLAMP CYLINDER, C68, 1256 lb

Auto switches can be mounted on any of the 4 surfaces with no projection of the switch.Rotary clamp cylinder w/auto switch mounting grooves, Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, Standard stroke (mm): 10, 20, 30, 50 (depending on bore size), Clockwise or counterclockwise rotary direction, Auto switch capable, Cylinder, Rotary Clamp, CLAMP CYLINDER, C70, 1324 lb

/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ004-H1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol20 to 904.0 (at 20C)2.5 (at 20C)?

/60 Hz) (l /min)Power supplyBreaker capacity (A)Rated current (A)AlarmCommunicationsHRZ004-L1Water-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35C, Humidity: 30 to 70%RHAqueous solution of 60% ethylene glycol?

/60 Hz) (l/min)Power supplyBreaker capacityRated currentAlarmCommunications( C)(MPa)(A)(kg)HRZ010-WSWater-cooled refrigerationR404A (HFC)PID controlTemperature: 10 to 35 C, Humidity: 30 to 70%RH?