Plate A Plug (M-3P) (2 pcs.)
Double acting PA PA B A PB B A With by-pass Suck back valve Manual Operation-Series LVH N.C. Double acting P PA PA Locking and non-locking types available B A B A PB B A Integral fitting type/Threaded type Manifolds Main applications and fields For shut off For air bleeding N.C.
[Check valve] A check valve is a safety device intended to prevent reverse flow. The AP 64 is a unique design with only one moving part in the gas stream, an O-ring. It is a springless design, free of springs and poppets. [Vacuum generator] A venturi device that creates vacuum by flowing gas through a nozzle.
(B) 2 (A) 4 Symbol 1 (P) 3 (R) Flow Rate Characteristics C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 14/2(PA/B) 4/25/3(A/BEA/EB) Flow rate characteristics Port size Valve model Body ported 10-VQD1121(V)-L M-M5 10-VQD1121 -L M-M5 10-VQD1151(V)-L M-M5 10-VQD1151W-L M-M5 0.05 0.07 0.06 0.07 Base mounted (With sub-plate) 0.19 0.28 0.22 0.27 0.31 0.28 0.31 0.28 0.22 0.27 0.22 0.27 0.16 0.24 0.10 0.25
VDC0.5 A/output2 A/unitShort-circuit protection?
Circuit (Class 2) of maximum 30 Vrms (42.4 V peak) or less, with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer. The product is a UL approved product only if it has a mark on the body. Use the specified voltage. Otherwise failure or malfunction can result. Insufficient supply voltage may not drive a load due to a voltage drop inside the product.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
When a long stroke is necessary. A long stroke is possible. Model Selection Operating conditions E: Kinetic energy of load (J) (W + WB) V 2 E = x ( ) 2 x 2.2 39.4 Es: Allowable kinetic energy for intermediate stop using an air pressure circuit (J) Fn: Allowable driving force (lbf) Ps: Operating pressure limit for intermediate stop using an external stopper, etc.
3.3 W (0.14 A) 0.9 W Standard Power consumption (When rated voltage is at 24 V) With powersaving circuit Inrush Holding Coil switching noise Note 6) 50 dB Note 1) Select an appropriate material for the wetted part when fluid such as a cleaning solvent is used.
A Round head combination screw M3 2 1 + "+" mark "" mark A Round head combination screw M3 Conduit terminal View A-A (Internal connection diagram) There is polarity only when equipped with light.
Normal In a moving car, normal conversation, or in a department store 60 dB In a car driving at high speed, in a noisy office, or the sound of cicadas (close distance) 70 dB Noisy On a running train, ambulance siren (close distance), or inside a pachinko parlor 80 dB 90 dB Very loud Karaoke bar (in the center) or the barking of a dog (close distance) Refrigerant-free Fluid contact material
As a result, the cylinder actuates. For this reason, when a workpiece must be lowered, use a cylinder with a built-in brake mechanism so that the cylinder will not actuate.
order as shown in the Figure a.
Install a suitable filter (strainer) immediately upstream from the valve. As a general rule, use 80 to 100 mesh. Caution 1.
Seal 0 1 Metal seal Rubber seal 12 SI unit Serial Unit (SI Unit) Dimensions/EX250 DeviceNet PROFIBUS-DP CC-Link SI SI SI PW PW(V) RUN PWR(V) MOD/NET PWR(V) PWR STATION NO.
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
L L+A Fig. 1 Fig. 2 L 2 1 V E = W ( ) 2 1000 Collision speed V = 1.4 Va Find the kinetic energy E (J) of the load. 1 420 E = 1 ( ) = 0.088 2 1000 V = 1.4 x 300 = 420 Correction factor (reference value) Find the allowable kinetic energy Ea (J).
Plug that A port to avoid mistaking B port for the A port.
A Round head combination screw M3 2 1 + "+" mark "" mark A Round head combination screw M3 Conduit terminal View A-A (Internal connection diagram) There is polarity only when equipped with light.