Stations: 8 Stations, Port Size: N7 (1/4" One-touch Fitting), Cable Length: 2 (3.0m Cable 25 Pin), Option 1: None, Option 2: S (Built-in Silencer, Direct Exhaust)

Stations: 10 Stations, Port Size: N7 (1/4" One-touch Fitting), Cable Length: 2 (3.0m Cable 25 Pin), Option 1: None, Option 2: S (Built-in Silencer, Direct Exhaust)

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N7 (1/4), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)

Actuation: 2 (2-Position Double), Electrical Entry: TT (Terminal Type), Lead Wire Length: 10 (1000mm), Manual Override: Non-locking Push Type, A,B Port: N7 (ø1/4" One-touch Fitting, Inch), Thread Type: N (NPT)

Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 4 (220VAC 50/60HZ), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: None, Port Size: N7 (1/4" One-touch Fitting)

D-sub Connector Type: B (26 Poles), Connector Entry Direction: 2 (Lateral), Valve Stations: 06, SUP/EXH Block Fitting Entry Direction: 2 (Side), SUP/EXH Block Port Size: N7 (ø1/4" One-touch Fitting, Straight), Mounting Option: F1 (w/Bracket, Standard)

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: None (Straight), Port Size: N7 (1/4), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m)

D-sub Connector Type: B (26 Poles), Connector Entry Direction: 2 (Lateral), Valve Stations: 09, SUP/EXH Block Fitting Entry Direction: 2 (Side), SUP/EXH Block Port Size: N7 (ø1/4" One-touch Fitting, Straight), Mounting Option: N [Manifold Direct Mounting Type (10-32 UNF)]

Rated Control Flow Range: 11 (1 to 100 L/min), Port Size: N7 (1/4 inch), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)

Stations: 06 Stations, Port Size: N7 (w/ø1/4" One-touch Fitting), SI Unit: EB (EtherNet/IPâ„¢ IO-Link), End Plate: 2 [Power Supply w/M12 Connector (Max. supplied Current 2 A)], SI Unit Common: N (-COM)

Enclosure: W (IP67), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 2 Stations, P, E Port Entry: D (D Side 2~10 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting)

Stations: 08 Stations, Port Size: N7 (w/ø1/4" One-touch Fitting), SI Unit: EB (EtherNet/IPâ„¢ IO-Link), End Plate: 2 [Power Supply w/M12 Connector (Max. supplied Current 2 A)], SI Unit Common: N (-COM)

The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication

The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication

The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication

The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, .55115 lb

Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N7 (ø1/4 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N7 (ø1/4 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N7 (ø1/4 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]