SMC Corporation of America
Elite Part Number Search
Search Results "LEFS25RT6B-800-S2"

Insulation resistance 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller. Vibration resistance 490 m/s2 in X, Y, Z directions 3 times each Impact resistance 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Noise resistance 200 g 240 g Weight Note 3) Port size (Rc, NPT, G) 1/8, 1/4 3/8 1/2 Note 1) The system accuracy when combined with PF2A2/3.

P1 LED lever meter Sensor S1 S3 Red is on: Output OFF Green is on: Output ON S4 S2 + P2 Red 1 Gap too big S1, S2: Fixed orifice S3: Variable orifice (Set via adjustment knob) S4: Detection nozzle Red 2 Green 1 BEST POSITION The bridge circuit is constructed as shown in the diagram. Position the work piece in front of the nozzle (S4).

Dimensions 4-3.2 circuit board mounting hole Circuit board type DC24V MADE IN JAPAN + PCW-EC16Z00 4 4 YMX-F4 42 0 1 2 3 4 5 6 7 8 9 A B C D E F 1 + *S2 S1 2 3 4 4 4 (28.5) 3 130 With cover (DIN rail mount compatible) With cover (DIN rail mount compatible) 16.7 DC24V MADE IN JAPAN + PCW-EC16Z01 28.3 YMX-F4 45 0 1 2 3 4 5 6 7 8 9 A B C D E F 1 + *S2 S1 4.1 2 3 4 (48.5) 5.1 (50) 133 10.5 10.5

Without release valve Without pressure sensor/switch for vacuum With pressure sensor 30 m/s2 Vibration resistance Note 1) Pilot operated dual 2 port Pilot operated 2 port Valve configuration 20 m/s2 0.3 to 0.6 MPa Operating pressure range With switch for vacuum Poppet seal Valve construction Without pressure sensor/switch for vacuum With pressure sensor 150 m/s2 Impact resistance Note 2)

Note 3) For detailed specifications other than the above, refer to the separate technical operation manual that can be downloaded from SMCs website (http://www.smcworld.com/). 10 to 150 Hz with a 0.035 mm amplitude or 4.9 m/s2 in each X, Y, Z direction for 2 hrs (De-energized) 147 m/s2 in each X, Y, Z direction, 3 times (De-energized) Standard CE marking, UL (CSA) Communication connector

Address Description of bytes tion unit range Input Mode D0410 4 Target position [m] Note 1) 1 Note 1) No D0412 2 Positioning time [0.01s] 1 0 to 6000 No D0413 2 Speed [mm/s] 1 0 to 400 No D0414 2 Acceleration [mm/s2] 1 0 to 60 No D0415 2 Deceleration [mm/s2] 1 0 to 60 No 1 to 20, Pushing speed [mm/s] D0416 2 1 No 32768 to Note2) 32788 Thrust setting value Note 3) More than D0417 2 1 Yes [

External terminals (including the FE terminal) and enclosure screws Insulation resistance 10 M or more 500 VDC External terminals (including the FE terminal) and enclosure screws EN61131-2 compliant 5f<8.4 Hz 3.5 mm Vibration resistance 8.4f<150 Hz 9.8 m/s2 Impact resistance EN61131-2 compliant, 147 m/s2, 11 ms Mounting Through hole for M4 screw (2 pcs.)

ZB-OM00201-B Specifications General Specifications Ambient -5 to 50oC (No condensation) temperature range Fluid Air, inert gas Vibration 30m/s2 (Without pressures sensor/vacuum pressure switch, With pressure sensor) resistance Note 1) 20m/s2 (With switch) Impact 150m/s2 (Without pressures sensor/vacuum pressure switch, With pressure sensor) resistance Note 2) 100m/s2 (With switch) Note 1)

(STO switch) S2: Start switch (STO release switch) S3: On switch S4: Off switch KM1: Magnetic contactor K3: Safety relay EMG: Emergency stop switch CN3 EM1 or EM2 M Servo motor Note.

Mount the switch in a location where there is no vibration greater than 98 m/s2, or no impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.

Do not drop, bump, or apply excessive impacts (300 m/s2 or more for reed switches and 1000 m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.

The operating time for D-J51 is 2 ms or less and for D-P3DW/P4DW are 40 ms or less. 4) 980 m/s2 for the trimmer type sensor section, 98 m/s2 for the amplifier section.

Movement Load : Angular acceleration F: Pressing force (N) T f = F x l (Nm) . 2 = (rad/s 2) Load Static torque calculation t 2 g = 9.8 m/s2 Ts = F x l (Nm) l : Rotation angle (rad) Lever t : Rotation time (S) Axis Rotary actuator Axis Allowable Load Application of the load on the axial direction is tolerated if no dynamic load is generated and the values are within what is shown in the

Program P1 P2 P3 P16 S1 S1 S1 S1 S2 S2 S2 S2 Step S32 S32 S32 S32 Following are CEU2s special feature: 1. Predictive Control & Learning Function (Allow High Repeatability and Precision. 0.5mm) With learning function, after every execution, brake point will be amended, according to the deviation of stopping position from setting position.

The operating time for D-J51 is 2 ms or less and for D-P4DWL is 40 ms or less. 4) 980 m/s2 for the trimmer type sensor section, 98 m/s2 for the amplifier section.

Indicator light Standard Conforming to CE Standards Lead wire Oilproof heavy-duty vinyl cable, 6, 0.5 mm2, 2 cores, 300 mm Impact resistance Switch: 1000 m/s2, Connector: 300 m/s2 Insulation resistance 50 Mor more at 500 VDC Mega (between lead wire and case) Withstand voltage 1000 VAC for 1 minute (between lead wire and case) Ambient temperature 10 to 60C Enclosure IEC529 standard

Do not drop, bump or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.

Possible to use in vacuum applications Up to 100 kPa Non-locking push type Push-turn locking slotted type Push-turn locking lever type Manual override Pilot exhaust type Lubrication Mounting orientation Impact/Vibration resistance (m/s2) Note) Individual exhaust Not required Unrestricted 300/50 Dust-tight (IP65 for D, Y, T) Series VP300 Enclosure Note) Impact resistance: No malfunction occurred

Operating: 0 to 50C, Stored: 10 to 60C (with no freezing and condensation) Resistance Operating or Stored: 35 to 85%RH (with no condensation) 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs., whichever is smaller.