(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. EtherNet/IPTM communication is not established. Green flashing 4 EtherNet/IPTM communication is established. Green ON NS EtherNet/IPTM communication is time-out. Red flashing Valve plate (EX600-ZMV ) IP address is duplicated. Red ON Safety Instructions (5)Connect the SI unit to the valve manifold.

(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. 4 Link, No Activity (100 Mbps) Link, Activity (100 Mbps) Link, No Activity (10 Mbps) Link, Activity (10 Mbps) L/A PORT2 Valve plate (EX600-ZMV#) Refer to the SMC website (URL https://www.smcworld.com) for more information about LED state. Safety Instructions (5)Connect the SI unit to the valve manifold.

(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. Single Flash Safe operational status (Green) ON Operational status 4 OFF No communication error Flash Communication setup error Valve plate (EX600-ZMV ) (Red) Double Flash Communication error (application watchdog timeout) Safety Instructions (5)Connect the SI unit to the valve manifold.

(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. 4 Valve plate (EX600-ZMV ) Safety Instructions (5)Connect the SI unit to the valve manifold. Insert the valve plate into the valve plate mounting groove on the side of the SI unit.

(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. 4 LED Display 300 g Weight Refer to the product catalogue or SMC website (URL https://www.smcworld.com) for more information about product specifications. Valve plate (EX600-ZMV#) The status display LED displays the power supply and communication status. Safety Instructions (5)Connect the SI unit to the valve manifold.

M3 hexagon screw Tightening torque: 0.6 Nm Tie-rod Tightening torque: 0.6 Nm If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident.

(M3 x 8) (Tightening torque: 0.6 to 0.7 Nm) Screw mounting place SV : 2 places S0700 : 2 places VQC1000: 2 places VQC2000: 3 places VQC4000: 4 places SY : 2 places JSY : 2 places (5) Connect the SI unit and the valve manifold. Insert the valve plate to the valve plate set groove on the side of SI unit. Then, tighten it with the valve plate set screws (M4 x 6) to fix the plate.

(M3 thread) (It is recommended to ground with resistance of 100 ohms or less) Power supply (0 VDC) 3 6 4 4 3 20 m or less total extension per branch Branch cable length Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof.

M3 x 18: 2 pcs. (Hexagon socket head cap screw (with spring washer)) CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Solenoid valve or End Plate R (Output Block side) Warning: WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Tie-rod: 2 pcs.

Install the product (with bracket) using the M3 screws (4 pcs.). Bracket thickness is approximately 1.2 mm. 2. Press the or button to change the set value. The button is to increase and the button is to decrease the set value. : If the error cannot be reset after the above measures are taken, then please contact SMC.

Flow indicator LED Safety Instructions Square groove Install the product (with bracket) using the M3 screws (4 pcs.). Bracket thickness is approximately 1.2 mm. Power indicator LED Indicates the power supply status. LED is ON (Green) when power is ON. LED is ON (Red) when a system error occurred.

M3 (2 ) (M315 L) 0.320.02 Nm L M315L () M315L L () L () M4 (2 4 ) 1mm (22 ) -14No. PF-OMK0003CN-E 0.320.02 Nm L () L () M4 (2 4 ) 1mm (22 ) -15No. PF-OMK0003CN-E 11.5mm , , , , IN 500kPa /KQ2 mm KQ2H04-M5 KQ2S04-M5 4 M50.8 KQ2L04-M5 /KJ mm KJH04-M5 KJS04-M5 4 M50.8 KJL04-M5 /M mm 4 M-5AN-4 M50.8 6 M-5AN-6 -16No.

Flow range Applicable screws Tightening torque 04 Equivalent to M3 (L=6) 0.04 to 0.05 Nm 20 40 Equivalent to M4 (L=10) 0.09 to 0.10 Nm The stop valve of the product is not suitable for adjusting the flow rate. When the flow rate needs to be adjusted, please select the product with flow adjustment valve. Do not hold the handle of the stop valve when it is carrying around.

They are all important notes for safety and must be followed in addition to International standards (ISO/IEC) and other safety regulations. 04 Equivalent to M3 (L=6) 20 0.04 to 0.05 Nm 40 Equivalent to M4 (L=10) 0.09 to 0.10 Nm Element Description This unit supplies the fluid from the supply side main piping to the application.

. -14No.PF-OMN0012-H Mounting and Installation Installation Mounting with panel mount adapter Fix the panel mount adapter to the flow monitor with the screws supplied M3 x 8 L (2 pcs.).

Water hammer Window comparator mode An operating mode in which the switch output is turned on and off depending on whether the flow is inside or outside the range of two set values -12No.LFE*-OMZ0013 Mounting and Installation Installation Mounting by panel mount adapter Fix the panel mount adapter to the controller by the mounting screws M3 x 8L (2 pcs.).

(Recommend using an M3 Phillips head screwdriver with magnet.) Disconnect the piping on top and bottom of the valves and remove the connector for wiring. Replace the valves with new ones. Note) Notes: Mounting orientation of the valves is specified. Make sure that the connector for wiring should be on the upper side of the valve.

(Recommend using an M3 Phillips head screwdriver with magnet.) Disconnect the piping on top and bottom of the valves and remove the connector for wiring. Replace the valves with new ones. Note) Notes: Mounting orientation of the valves is specified. Make sure that the connector for wiring should be on the upper side of the valve.

Dynamic viscosity [m2/s] Viscosity [Pas] Density [kg/m3] Viscosity and dynamic viscosity are obtained by the formulas below. Dynamic viscosity [cSt] Viscosity [mPas] Density [g/cm3] 1 [mPas1 [cP] 14 Working Principle 1. When air is supplied to P1 port, it enters drive chamber A. 2. Diaphragm A moves to the left, and at the same time diaphragm B also moves to the left. 3.

Dynamic viscosity [m2/s] Viscosity [Pas] Density [kg/m3] Formulas below can be used for common units 1cP = 1mPas = 10-3Pas 1cSt = 1mm2/s = 10-6m2/s 14 Working Principle 1. When air is supplied to P1 port, it enters drive chamber A. 2. Diaphragm A moves to the left, and at the same time diaphragm B also moves to the left. 3.