SMC Corporation of America
Elite Part Number Search
Search Results "IZD10-110"

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, 3000 SERIES 5 PORT VALVE, 4/5 PORT

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, 3000 SERIES 5 PORT VALVE, 4/5 PORT

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, 3000 SERIES 5 PORT VALVE, 4/5 PORT

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, Direct Op 3 Port Solenoid Valve, COM, 3 PORT SOLENOID VALVE, K44, 440.00000 lb

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, Direct Op 3 Port Solenoid Valve, COM, 3 PORT SOLENOID VALVE, K44, 640.00000 lb

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, Direct Op 3 Port Solenoid Valve, N.C., 3 PORT SOLENOID VALVE, K44, 810.00000 lb

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, EB, VX3 BODY PT 1/4NPT, 1.10231 lb, ModelOrifice dia.Port size1.5 mm?2.2 mm?3 mm?

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, EC, VX3 BODY PT 1/4NPT, 1.25112 lb, Port sizeOrifice diameter (mm?)

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, EC, VX3 BODY PT 1/4NPT, 1.41680 lb, Port sizeOrifice diameter (mm?)

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, EC, VX3 BODY PT 1/4NPT, 1.32656 lb, ModelOrifice dia.Port size1.5 mm?2.2 mm?3 mm?

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, EA, VX3 BODY PT 1/4NPT, 1.54367 lb, ModelOrifice dia.Port size1.5 mm?2.2 mm?3 mm?

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, FC, VX3 BODY PT 1/4, 1.43479 lb

10% or less) (With power supply polarity protection)55 mA or less (Not including the current consumption of the sensor)Same as [Power supply voltage]Max. 110 mA (However, the total current for the 4 inputs is 440 mA maximum or less.)1 to 5 VDC (Input impedance: Approx. 800K )No. of inputsInput protectionSwitch output(Real-time switch output, Accumulated switch output)Switch output(Real-time

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110

Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, 3000 Series 5 Port Valve, 4/5 PORT