SMC Corporation of America
Elite Part Number Search
Search Results "AWM40-F04-6-D"

Nominal thread sizes Tightening torque M5 1/6 rotation after tightening by hand R 1/8, NPT 1/8 7 to 9 Nm 3. Apply wrench only to the metal part of the main housing when installing the pressure switch onto the system piping. Do not apply a wrench to the resin part as this may damage the switch. 10 Series ZSE30/ISE30 Digital Pressure Switch Precautions Be sure to read before handling.

PUSH Terminal block marking Model A COM B T TURN 0 1 0 1 VQ410 A side COM LOCK VQ420 Caution A side COM B side 3 4 5 6 0 1 VQ4 0 A side COM B side Valve Mounting After confirming the gasket is correctly placed under the valve, tighten the mounting screws with the appropriate torque listed below. Note 1) Not polar, possible to use as COM.

MQR Symbol O.D. x I.D. 0425 4 x 2.5 0604 6 x 4 0805 8 x 5 1065 10 x 6.5 1208 12 x 8 Symbol Number of cores X169 2 cores X170 3 cores X171 4 cores X172 5 cores T T IDK Tube length per roll [m] Color*1 Symbol Length A 1 B 2 C 3 D 4 E 5 F 10 G 20 Symbol Color Symbol Color 1 Black 5 Yellow 2 White 6 Green 3 Red 7 Translucent*2 4 Blue 8 Yellow brown Yellow Blue Red White Black Inside of the roll

B PPS Non-leak (106 Pam3/sec), Medium vacuum (0.1 Pa.abs), Oil-free M FKM FKM V C37 Note) The leakage amount (10 6 Pam 3/sec) for the V and M option are values when the differential pressure is 0.1 MPa. 5

Fittings & Tubing Air Cylinders Rotary Actuators Nil 1 Note 6) Set pressure c 0.05 to 0.85 MPa setting 0.02 to 0.2 MPa setting + Polycarbonate bowl Metal bowl Nylon bowl Metal bowl with level gauge With bowl guard Nylon bowl with bowl guard + Nil 2 6 8 C 6C Bowl d Semi-standard J Drain port Note 7) Drain guide 1/8 Drain guide 1/4 + Nil N Exhaust mechanism e Relieving type Non-relieving type

0 Controller/Driver mounting LEC Nil Screw mounting D DIN rail mounting LEC S DIN rail is not included. Order it separately.

H Clean One-touch fittings D MS Applicable tubing O.D.

Port 3(R2) and 5(R1) are Rc 3/8 0.37 1/4 Bottom 3/8 3-10-6

VS7-6 How to Order E Q VS7 6 FG S 1 Symbol Number of solenoid Rated voltage Option Port size of sub-plate Connector S D Single Double 1 2 3 4 A02 Without sub-plate N None Indicator light 0 100V AC 200V AC 24V DC 12V DC Connector SV 1 4 FG Side piping FJG W/o connector M Direct manual override 3 8 A03 Side piping SY Thread Z Indicator light with surge voltage suppressor 1 4 B02 Bottom

N S NBR Silicone rubber U Urethane rubber U C Flat Flat with ribs F FKM Table (1) Pad Diameter/Pad Type GN Conductive NBR Diameter Type 2 4 x 10 3.5 x 7 2 x 4 4 6 8 10 13 16 20 25 32 40 50 D Deep GS Conductive silicone rubber B Bellows Flat with ribs Flat UT Thin flat CT Thin flat with ribs Deep Bellows Thin flat Thin flat with ribs Precautions Be sure to read this before handling the products

Body Class: 6 (Class 6, Orifice ø22), Valve Type: 0 (Normally Closed), Fitting Type: D (w/Double Ferrule Fittings), Applicable Tube Size: 25 (1), Pilot Port Thread Type: N (NPT 1/8), Material: AD (Body: Stainless Steel, Seal: FKM, Buffer: FKM, Diaphragm: PTFE), Option 1: 6 (High Back Pressure with Flow Rate Adjustment)

Body Class: 6 (Class 6, Orifice ø22), Valve Type: 0 (Normally Closed), Fitting Type: D (w/Double Ferrule Fittings), Applicable Tube Size: 25 (1), Pilot Port Thread Type: N (NPT 1/8), Material: ND (Body: Stainless Steel, Seal: EPDM, Buffer: EPDM, Diaphragm: PTFE), Option 1: 6 (High Back Pressure with Flow Rate Adjustment)

Stations: 6 Stations, Port Size: C6 (ø6 One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 6 (Input Block 6 pcs.), Input Block: 2 (M12, 4 Inputs), Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: D (DIN Rail Mounting), Option 2: None, US Option: X160US (Preferred US Option)

Stations: 6 Stations, Port Size: C6 (ø6 One-touch Fitting), SI Unit: ZENN (EtherNet/IP, -COM), Number of Input Blocks: 6 (Input Block 6 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: D (DIN Rail Mounting)

Stations: 6 Stations, Port Size: C8 (ø8 One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 6 (Input Block 6 pcs.), Input Block: 2 (M12, 4 Inputs), Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: D (DIN Rail Mounting), Option 2: None, US Option: X160US (Preferred US Option)

Stations: 6 Stations, Port Size: C6 (ø6 One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 6 (Input Block 6 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: N [NPN (-)], Option 1: D (DIN Rail Mounting), Option 2: R (External Pilot), US Option: X160US (Preferred US Option)

Stations: 6 Stations, Port Size: C6 (ø6 One-touch Fitting), SI Unit: ZENN (EtherNet/IP, -COM), Number of Input Blocks: 6 (Input Block 6 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: N [NPN (-)], Option 1: D (DIN Rail Mounting)

The hexagon wrench key VBA1 for VBA1 is with nominal size 4 and 6, for VBA2 with VBA2 nominal size 8, and for the drain port with nominal size 6. OUT port Safety valve port (J) Rc3/8 : Tighten the optional safety valve and drain valve with a monkey spanner.