SMC Corporation of America
Elite Part Number Search
Search Results "AC20C-N02CE-Z-D"

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint), Auto Switch: M9PV--Solid State , Gen

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 50mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 45mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 80mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 35mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: C (Rubber Bumper), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 40mm, Piping: Screw-in, Stroke: 125mm, Action: S (Single Acting Spring Return), Valve Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Light & Surge Suppressor: Z (Light & Surge Suppressor)

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 32mm, Piping: Screw-in, Stroke: 50mm, Cylinder Rod Motion: B (Energized Retract), Rod Boot: None, Function: 1 (2 Position Single), Valve Voltage: 3 (110VAC), Electrical Entry: D (DIN Terminal), Light & Surge Suppressor: Z (Light & Surge Suppressor)

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 40mm, Piping: Screw-in, Stroke: 50mm, Cylinder Rod Motion: B (Energized Retract), Rod Boot: None, Function: 1 (2 Position Single), Valve Voltage: 3 (110VAC), Electrical Entry: D (DIN Terminal), Light & Surge Suppressor: Z (Light & Surge Suppressor)

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 32mm, Piping: Screw-in, Stroke: 50mm, Cylinder Rod Motion: Energized Extend, Rod Boot: None, Function: 1 (2 Position Single), Valve Voltage: 3 (110VAC), Electrical Entry: D (DIN Terminal), Light & Surge Suppressor: Z (Light & Surge Suppressor)

Accessory (Option) Basic size (Applicable compressor kW) F With screw flange D With auto-drain Port size Symbol 2 Screw type Reciprocating type 2.2 7.5 15 22 37 55 75 04 06 14 20 30 Rc 1 2 Rc 3 4 Rc 1 1 2 Rc 2 3B flange HAW2 HAW7 HAW22/37 HAW55/75 HAW110 Caution on Design 7 22 22 Warning 1.

It was being requested that you indicate whether the D-M9N auto switch is to be rail mounted or band mounted. The auto switch part number of the old CJ2 series differed depending on whether it was to be mounted on a rail or on a band. With the current CJ2-Z series, both rail mounting and band mounting are available for the D-A9∗ and D-M9 small auto switches.

SMC Clamp CylinderFeatures· Reduced overall tube length· The screw type adjustment construction makes it easy to adjust the speed· The speed controller valve does not protrude out from the tube· With air cushioning· Strong magnetic field resistant auto switches can be mounted from 3 directionsD-P3DW and D-P4DW models supported (CKG1), D-P79WSE and D-P74L/Z models supported· Compatible with

Please consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.

Vacuum switch unit Filter unit Release flow rate adjusting needle Manual operation Vacuum switch Electrical entry Ejector exhaust Electrical entry PV/V port size Pilot valve Components Vacuum switch unit Valve unit N.C. type Ejector unit ZX1 1 10 5 L Z E C K1 L Vacuum switch unit Ejector unit 1 10 L Z E C K3 5 ZX1 Valve unit N.O. type Vacuum switch unit ZX1 1 10 E C Ejector unit CE compliant

Please consult with SMC regarding water resistant types with the above model numbers. 21 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.

Air Slide Table 12, 16 MXJ Series RoHS How to Order 12 10 Z M9BW MXJ Number of auto switches Bore size Nil 2 S 1 n n 12 12 mm 16 16 mm Auto switch Symmetric type Nil Without auto switch Standard For applicable auto switches, refer to the table below.

A water-resistant type cylinder is recommended for use in an environment which requires water resistance. 2 1 m lead wire is only applicable to the D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.

Areas where abrupt temperature changes may cause condensation. d. Areas where corrosive gas, flammable gas or other volatile flammable substances are stored. e. Areas where the product may be exposed to conductive powder such as iron powder or dust, oil mist, salt, organic solvent, machining chips, particles or cutting oil (including water and any liquids), etc. f.