25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns470 g3/8, 1/2
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Integrated display type , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EX, IFW/PFW 3/8INCH ALL OTHERS, 1.43300 lb, ModelMeasured
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Integrated display type , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EX, IFW/PFW 3/8INCH ALL OTHERS, 1.42451 lb, ModelMeasured
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Integrated display type , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EX, IFW/PFW 3/8INCH ALL OTHERS, 1.17579 lb, ModelMeasured
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M and more (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration in each X, Y, Z direction for 2 hrs, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M and more (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration in each X, Y, Z direction for 2 hrs, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M and more (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration in each X, Y, Z direction for 2 hrs, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns
5% F.S. or less (0 to 50C, based on 25C)70 mA or less520 g3/8, 1/2Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lOperating: 0 to 50C, Stored: ?
5% F.S. or less (0 to 50C, based on 25C)70 mA or less520 g3/8, 1/2Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lOperating: 0 to 50C, Stored: ?
5% F.S. or less (0 to 50C, based on 25C)70 mA or less520 g3/8, 1/2Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lOperating: 0 to 50C, Stored: ?
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M and more (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration in each X, Y, Z direction for 2 hrs, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns
SMC's new AF modular style air filter combines the element and bowl in one piece, making element replacement easy. There is a maximum 46% reduction in size, reducing required maintenance space. The AF bowl (size 30 and 40) is covered with a transparent bowl guard, allowing 360° monitoring. The modular design of the AF allows connection with other SMC air preparation equipment. The series
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet,
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for air applications , Integrated display type , Flow rate range: 1-10(l/min) ~ 50-500(l/min) , Output for display unit with or w/o analog output , Port sizes: 1/8, 1/4, 3/8, 1/2, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, EX, IF/PFA 3/8 INCH ALL OTHERS, .91860 lb, ModelMeasured
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, F/R/L COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, EA, AC MASS PRO 3/8 MODULAR (PT), 3.41716 lb
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, F/MS/R COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, EA, AC MASS PRO 3/8 MODULAR (PT), 3.63762 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, E7, IT2000 3/8 INCEUROPEAN, 1.59636 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, E7, IT2000 3/8 INCEUROPEAN, 2.42508 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, E7, IT2000 3/8 INCEUROPEAN, 1.10231 lb