Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, Direct Op 3 Port Solenoid Valve, COM, 3 PORT SOLENOID VALVE, 810 lb
Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, Direct Op 3 Port Solenoid Valve, COM, 3 PORT SOLENOID VALVE, 810 lb
Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, Direct Op 3 Port Solenoid Valve, N.C., 3 PORT SOLENOID VALVE, 840 lb
Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, SOFT START-UP VALVE, VALVE, SOFT START, 237, 0.27000 lb
Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, SOFT START-UP VALVE, VALVE, SOFT START, 239, 0.27000 lb
Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 72.0 (4.0); 2 position rubber seal 79.2 (4.4) 3 position metal seal 41.4 (2.3) - 72.0 (4.0); 3 position rubber seal 45.0 (2.5) - 79.2 (4.4), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 20 or less to 62 or less; rubber seal 25 or
Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient & fluid temperature: -10 to 50°C, VALVE, VALVE, VQZ100 VALVE, SOL 3-PORT, UA, VQZ100 BUILT IN FITTING
Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, VALVE, MEDIA, VALVE, VX3 3-WAY MEDIA VALVE, EB, VX3 BODY PT 1/4NPT
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BASE MOUNT, VALVE, VQZ300
50Hz) /AC200/220V (60Hz) () 10%4 7-2 200V 770/910 1260/1590 1770/2170 2270/2960 5) 50/60Hz W 200V 790/970 1150/1380 1700/2160 2330/2980 200V 4.2/4.6 6.7/7.9 9.7/10.9 11.8/14.8 5) 50/60Hz A 200V 3.0/3.2 4.3/4.4 6.5/6.8 8.9/9.1 (30mA) 6) A 200V 10 15 20 30 200V 15 20 10 R410AHFC)GWP2,0887 200V 39010 53010 63010 78010 g 200V 34010 52010 74010 75010 0.1MPa 12 mm R2 R1 R1 1/2 kg 49 68 95 110
Series 6-1 6 1 IDX-OM-W026 6 6-3 IDF22E, IDF37E Guige Guige ( 10) Guige (10) (820) 17 4-13 (17) [] mm A B C D E F G H J K L M N P IDF22E R1 775 6001 IDF37E R11/2 855 6801 85 340 (698) (93) 46 25 290 623 (134) (405) 13 314 IDF55E, IDF75E Guige Guige 10 (10, 1m 1m) 4-13 17 (911)[] mm A B C D E F G H J K L M N P Q R IDF55E 800 (868) IDF75E 900 (968) 526 (250) 5195 13 500 75 7001 (455) (110
(Note4) A 5.5 8.0 13.0 14.0 Applicable circuit breaker capacity (sensitivity current 30mA) (Note5) A 10 15 20 30 Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) GWP:2088 (Note6) Amount of refrigerant to be filled g 39010 53010 63010 78010 Auto drain Float type (Normally open: Min. operating pressure: 0.1MPa) Drain tube O.D. mm 12 Port size R1 R1 1/2 R2 Weight kg 49 68 95 110
12.0 13.0 Applicable earth leakage breaker capacity (sensitivity current: 30mA) A 10 15 20 30 Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) GWP:2088 (Note 7) Amount of refrigerant to be filled g 390 +/10 530 +/10 630 +/10 780 +/10 Auto drain Float type (Normally open: Min. operating pressure 0.1 MPa) Drain tube O.D. mm 12 Piping port size R1 R1 1/2 R2 Weight kg 49 68 95 110
IDFB11E IDFB15E 10 SCFM 15 SCFM 25 SCFM 41 SCFM 59 SCFM 71 SCFM (ANR) (1) 37 F (2.8C) (17 m 3/h) (25 m 3/h) (43 m 3/h) (70 m 3/h) (100 m 3/h) (120 m 3/h) 11 SCFM 16 SCFM 26 SCFM 43 SCFM 62 SCFM 80 SCFM 45 F (7.2C) (19 m 3/h) (27 m 3/h) (45 m 3/h) (74 m 3/h) (106 m 3/h) (136 m 3/h) 17 SCFM 28 SCFM 45 SCFM 65 SCFM 86 SCFM 12 SCFM 50 F (10C) (20 m 3/h) (28 m 3/h) (47 m 3/h) (77 m 3/h) (110
27.5 3.7 1.8 1 0.5 12.4 13.4 [290] [623] [134] [405] [698] [93] [46] [25] [13] [314] [85] [340] 26.8 33.7 IDFB37E 1/2 [855] [680] R IDFB55E/75E Q A B H G E D F C (0.4 (39.4[1000]) J L K M N P 4x0..5 [4x13] (M10) Unitinch [mm] A B C D E F G H J K L M N P Q R 31.5 34.2 IDFB55E 2 1.4 [800] [868] 18.5 33.7 5.0 17.9 4.3 9.8 2 0.5 19.70.1 3.0 27.60.04 20.7 20.40.2 [470] [855] [128] [455] [110
S. ) The l i m i t i s 1198h, dat a of 110% , but t he guarant eed accuracy i s up t o 100% F. S. I nput dat a occupi es 4 w ords, but uses onl y t he 1st w ord. The pressure i s m oni t ored by b15, b1, b0 dat a. ( b11 b0 cover 100% F.
(Refer to Drawing 3) Specification of type A cable VP 390 RxD/TxD-P Data Line 135 to 165 Impedance Capacitance between conductors 30 pF/m or less Data Line RxD/TxD-N 220 Conductor resistance 110 /km or less 390 DGND Cable diameter 0.64 mm or more 0.34 mm2 or more Conductor area Drawing 3 Communication wiring Connect PROFIBUS DP dedicated cables to the communication connector for PROFIBUS
Cable type Terminal resistor CC-Link dedicated cable CC-Link dedicated cable compatible to Ver.1.10 110 1/2 W (brown, brown, brown) 130 1/2 W (brown, orange, brown) CC-Link dedicated high performance cable 17 16 Display/ Switch Setting Wiring (continued) Power supply wiring Connect power supply wiring to the two power supply 2-pin connectors.
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110