For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time.
G46-10-01 2 pcs. G27-10-R1-X209 2 pcs. G27-10-R1-X209 2 pcs. G46-10-01 2 pcs.
offset=10 Changed to Origin offset-10 Origin 50mm 0 10 20 30 40 50 CCW CW Stroke[mm] Origin 50mm 10 20 30 40 50 60 CCW CW Stroke[mm] Origin 50mm -50 -40 -30 -20 -10 0 CCW CW Stroke[mm] Origin 50mm -40 -30 -20 -10 0 10 CCW CW Stroke[mm] Origin 50mm -60 -50 -40 -30 -20 -10 CCW CW Stroke[mm] -25- 4.
Useable range 10 10 Load Work piece Useable range 5 5 Fn 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 7 8 9 10 11 7 8 9 1 01 11 21 31 41 5 Lo Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3B40 CY3B20 Selection example 500 200 Given a load drive resisting force of Fn = 100 (N) and a distance from the cylinder shaft center to the load application point of Lo =
Useable range 10 10 Load Work piece Useable range 5 5 Fn 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 7 8 9 10 11 7 8 9 1 01 11 21 31 41 5 Lo Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3B40 CY3B20 Selection example 500 200 Given a load drive resisting force of Fn = 100 (N) and a distance from the cylinder shaft center to the load application point of Lo =
70 0.01 2 40 6000 100 40 0.1 3 90 1000 20 1 4 10 +3 5 5 10 +7 6 0 < Cp 5 +10 7 5 < Cp 10 Cw 0.5 8 0.5 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to be used in order to check the filter performance for each of the three kinds of contaminants, is indicated below.
.*2 Screw-in type Nil Without nozzle 01 Symbol Size Nil Rc3/8 N NPT3/8 F G3/8 50 mm IBG1-12-10-50 02 100 mm IBG1-12-10-100 03 150 mm IBG1-12-10-150 04 300 mm IBG1-12-10-300 11 Long nozzle*1 With S coupler/One-touch fitting 50 mm IBG1-12-10-50S 12 100 mm IBG1-12-10-100S 13 150 mm IBG1-12-10-150S 14 300 mm IBG1-12-10-300S Symbol Applicable tubing O.D. Part no.
), ripple max. 10% voltage Power supply spec.
Refer to the table for each pressure specification (page 80) Display/set pressure range Display/min. setting unit Power supply voltage 12 to 24 VDC (10%), and ripple (p-p) 10% at max. Electric spec.
Bowl Assembly Specifications 10-14 7. Assembly of Optional Parts 15 8. Operation and Adjustment 16-19 8-1. Adjustment of Dripping Amount 16 8-2. Lubrication 17-18 8-3. Oil Discharge from the Product with Drain Cock 19 9. Trouble Shooting 20 10. How to Replace the Components 21-30 10-1. Bowl Assembly Replacement 21-23 10-2. Bumper Retainer Assembly Replacement 24-27 10-3.
0EN-PSRJ Cable length (L) 01 1000 [mm] 02 2000 [mm] 03 3000 [mm] 05 5000 [mm] 10 10 [mm] Item Specifications Connector M12 Straight RJ45 Cable O.D. 6.4 mm Nominal cross section AWG26 Min. bending radius (Fixed) 26 mm Fig. 9-3 EX9-ACxx0EN-PSRJ -36No.EX-OMY0014-A (4) Cable with communication connector (M12 M12, Straight) Part number: EX9-AC 005 EN-PSPS Cable length (L) 005 500 [mm] 010 1000
HOW TO ORDER AF 30 03 BD 1N A 1 3 4 5 2 1 Symbol Description Body size 10 20 30 40 50 60 Meter thread (M5) Rc N NPT F G Thread type Nil 2 M5 M5 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 Port size 3 Nil Without mounting option B With bracket a Mounting Option 4 Nil Without auto drain C With float type auto drain (N.C.)
Panel adapter B ZS-22-02 Thread type Piping port size Rc NPT G Nil N F 01 02 1/8 1/4 Specifications PFA301-m PFA300-m Model Specifications Note 1) 1 to 10, 5 to 50l/min (0.04 to 0.35, 0.18 to 1.77SCFM) Flow rate range measurement & setting Minimum setting unit 1% of maximum flow rate range Model PFA510-m PFA550-m Real-time flow rate l/min, CFM x 10-2 Display units Measured fluids Dry air,
For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time. Insufficient warm-up time Product failure Replace the product. -71No.PS-OMU0009-D Problem No.
Applicable tube external DIA. 10 NPT3/8" 10 NPT3/8" 10 NPT3/8" Note 2 Option Semi-standard Semi-standard Port thread Part no. Rc G NPT AD47N-8(Z)-A AD47-8-A B External appearance drawing and part no. Applicable tube external DIA. 10 NPT3/8" 10 NPT3/8" 17 Note 2 Note 2 Option Semi-standard Semi-standard Semi-standard Part no. Part no.
Applicable tube external DIA. 10 NPT3/8" 10 NPT3/8" 10 NPT3/8" Note 2 Option Semi-standard Semi-standard Port thread Part no. Rc G NPT AD37N-8(Z)-A AD37-8-A B External appearance drawing and part no. Applicable tube external DIA. 10 NPT3/8" 10 NPT3/8" 14 Note 2 Note 2 Option Semi-standard Semi-standard Semi-standard Part no. Part no.
How to Order 10 SY 5 L 5 1 20 01 Clean series Bracket Series Nil: Without bracket F1: With foot bracket A, B port size 3 10-SY3000 5 10-SY5000 Thread piping 2 position single only Coil type Symbol Port size M5 x 0.8 10-SY3000 Applicable series 7 9 10-SY7000 10-SY9000 M5 Standard Nil 1 8 01 10-SY5000 T With power saving circuit (24, 12 VDC only) Actuation type 1 4 10-SY7000 02 02 03 2 position
AF-OMX0052-C PRODUCT NAME Air Filter MODEL / Series / Product Number AF20-(F,N)01(F,N)02(B,C)(-2,6,C,J,L,R,Z)-D AF30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,L,R,W,Z)-D AF40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,L,R,W,Z)-D AF40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-D AF50-(F,N)06(F,N)10(B,C,D)(-2,6,8,J,L,R,W,Z)-D AF60-(F,N)10(B,C,D)(-2,6,8,J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2-7 2.
10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min 1m = 3.28ft 1l/min = 0.035SCFM Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.