/2, Non Plug-in Standard 1/2), Thread: T (NPTF)
1/2, Non Plug-in Standard 1/2), Thread: T (NPTF)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 12 (1 1/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 12 (1 1/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 12 (1 1/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: A (Calibration
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 12 (1 1/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: A (Calibration
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 12 (1 1/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector)
Model: 20 (1500 L/min), Pressure Range: 1 (0.005~0.1MPa), Power Voltage: 0 (24VDC), Input Signal: 1 (Current Style 0~20mADC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: T (NPTF), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: L (Right Angle Style 3m), Pressure Display Unit: 5 (kPa)
Model: 20 (1500 L/min), Pressure Range: 1 (0.005~0.1MPa), Power Voltage: 0 (24VDC), Input Signal: 1 (Current Style 0~20mADC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: T (NPTF), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: N (w/oCable Connector), Pressure Display Unit: 5 (kPa)
Model: 20 (1500 L/min), Pressure Range: 1 (0.005~0.1MPa), Power Voltage: 1 (12~15VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: T (NPTF), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: N (w/oCable Connector), Pressure Display Unit: 4 (PSI)
Model: 20 (1500 L/min), Pressure Range: 1 (0.005~0.1MPa), Power Voltage: 1 (12~15VDC), Input Signal: 2 (Voltage Style 0~5VDC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: T (NPTF), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: C (L Bracket), Cable Connector: L (Right Angle Style 3m)
Model: 20 (1500 L/min), Pressure Range: 1 (0.005~0.1MPa), Power Voltage: 1 (12~15VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: T (NPTF), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: L (Right Angle Style 3m)
Model: 10 (200 L/min [ANR]), Pressure Range: 1 (0.005~0.1MPa), Power Voltage: 0 (24VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: T (NPTF), Port Size: 1 [1/8 (1000)], Accessory: B (Flat Bracket), Cable Connector: S (Straight Style 3m), Pressure Display Unit: 5 (kPa)
Model: 10 (200 L/min [ANR]), Pressure Range: 1 (0.005~0.1MPa), Power Voltage: 1 (12~15VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: T (NPTF), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: S (Straight Style 3m), Pressure Display Unit: 4 (PSI)
Model: 10 (200 L/min [ANR]), Pressure Range: 1 (0.005~0.1MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: T (NPTF), Port Size: 1 [1/8 (1000)], Accessory: C (L Bracket), Cable Connector: L (Right Angle Style 3m), Pressure Display Unit: 4 (PSI)
Model: 20 (1500 L/min), Pressure Range: 1 (0.005~0.1MPa), Power Voltage: 1 (12~15VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: T (NPTF), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: B (Flat Bracket), Cable Connector: S (Straight Style 3m), Pressure Display Unit: 4 (PSI)