BBA1: For D-A5/A6/F5/J5 BBA3: For D-B5/B6/G5/K5 The stainless steel bolts described above are used when the D-F5BAL/G5BAL type switch is shipped mounted on a cylinder. When the switches are shipped as individual parts, the BBA1 and BBA3 set are included.
BBA1: For D-A5/A6/F5/J5 types * Refer to the Web Catalog or Best Pneumatics Catalog for details on the BBA1. The above stainless steel screws are used when a cylinder is shipped with the D-F5BA auto switch.
NPN type PNP type Parallel input/output Parallel input/output Signal power supply Signal power supply Parallel IO connector Parallel IO connector 24VDC 24VDC A1 COM A1 COM A2 COM A2 COM A3 IN0 A3 IN0 A4 IN1 A4 IN1 A5 IN2 A5 IN2 A6 IN3 A6 IN3 A7 IN4 A7 IN4 A8 IN5 A8 IN5 A9 SETUP A9 SETUP A10 HOLD A10 HOLD A11 DRIVE A11 DRIVE A12 RESET A12 RESET A13 SVON A13 SVON Load B1 OUT0 Load B1 OUT0
PD07]5.8 03h _ x _ _ 0h x _ _ _ 0h 5 40 5. [] PD12 *DOP1 D-1 _ _ _ x 0h _ _ x _ 0h _ x _ _ 0h x _ _ _ / (A5) 0 1 0h PD14 *DOP3 D-3 _ _ _ x 0h _ _ x _ WNG()ALM() 0h (1) 0 1 WNG 0 1 ALM 0 1 WNG 0 0 1 ALM 1 (2) 1. 0OFF 1ON 2. ALMOFF _ x _ _ 0h x _ _ _ 0h 5 41 5. 5.2.5 2 ([Pr.
Wiring diagram LECP6N(NPN) LECP6P(PNP) Power supply 24 VDC for I/O signal CN5 Power supply 24 VDC for I/O signal CN5 A1 A1 COM+ COM+ COM COM A2 A2 A3 A3 IN0 IN0 A4 A4 IN1 IN1 A5 A5 IN2 IN2 A6 A6 IN3 IN3 A7 A7 IN4 IN4 A8 A8 IN5 IN5 A9 A9 SETUP SETUP A10 A10 HOLD HOLD A11 A11 DRIVE DRIVE A12 A12 RESET RESET A13 A13 SVON SVON Load Load B1 B1 OUT0 OUT0 Load Load B2 B2 OUT1 OUT1 Load Load B3 B3
HEC002-A5* HEC006-A5* Keep this manual available at all times.
Contact Protection Boxnnternal Circuit Ssries CU lulo Snift Auto Switch Mounting Position (At Stroke end) Minimum Auto Switch Mountable Stroke D-A5.A6 D-F5.J5 Minimum auto switch mounting strokes are as lollows due to the space necessarv to mount it. n: No, of auto switches With 2 swilches with I swilch 15 90 100 1 1 0 '120 (same surface) 15+559 n=l .2.8,4... 90+55!11 100+55!
D-A5/A6, D-A59W Tie rod mounting D-G3/K3 Band mounting Solid state swich D-F5/J5, D-F5NT, D-F5W/J59W, D-F5BA, D-F5F Tie rod mounting 1.10-1 Air Cylinder/Standard Series CS1 Lube, Non-lube: 125, 140, 160, 180, 200, 250, 300 Air-hydro: 125, 140, 160 How to Order CS1 L 300 160 JR Rod boot/Cushion Rod boot Mounting J K N R H Nylon tarpaulin Heat resistant tarpaulin No cushion With cushion on
MY1M16/20 Stroke (LL) L 4-MM depth M 2 x 2-B counterbore depth C LD through-hole PA U1 LW U3 U2 MX QW NW PB MTS U6 MY U4 U5 CY PG Q + Stroke Detailed figure of U section MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com W U M5 x 0.8 (Port) M5 x 0.8 (Hexagon socket
BBA1: For D-A5/A6/F5/J5 BBA3: For D-B5/B6/G5/K5 The stainless steel bolts described above are used when the D-F5BAL/G5BAL type switch is shipped mounted on a cylinder. When the switches are shipped as individual parts, the BBA1 and BBA3 set are included.
A5 IN3 A5 IN3 A6 DRIVE A6 DRIVE A7 SVON A7 SVON Internal resistance 10 [k] Internal resistance 10[k] A8 NC A8 NC A9 NC A9 NC Main circuit Main circuit Output signal power Output signal power supply supply A10 NC A10 NC 24 VDC 24 VDC DC2(+) B1 DC2(+) B1 DC2(-) B2 DC2(-) B2 BUSY B3 BUSY B3 B4 ALARM B4 ALARM B5 OUT0 B5 OUT0 B6 OUT1 B6 OUT1 Maximum Output current Maximum Output current B7 NC
A5 IN3 A5 IN3 A6 DRIVE A6 DRIVE A7 SVON A7 SVON Internal resistance 10 [k] Internal resistance 10[k] A8 NC A8 NC A9 NC A9 NC Main circuit Main circuit Output signal power Output signal power supply supply A10 NC A10 NC 24 VDC 24 VDC DC2(+) B1 DC2(+) B1 DC2(-) B2 DC2(-) B2 BUSY B3 BUSY B3 B4 ALARM B4 ALARM B5 OUT0 B5 OUT0 B6 OUT1 B6 OUT1 Maximum Output current 10 mA Maximum Output current
iCW " 2pes lOn differer\1 15 " D.J59W lace Cor same lace)
A small area of the connector is raised on the controller side. 18 - 3. 5 I/O cable (1) How to Order (2) Parallel I/O plug terminal table LATH2LATH5L A T H Terminal Insulator Insulator number colour Dot Dot colour colour A1 Red Light brown Red A2 Grey Black A3 Grey Yellow Red A4 Grey Black Cable length(L) I/O cable type A5 Green Light green Red A6 Grey Black 1 1m 2 Without shield A7 Grey
Most sensitive position 11-11-9 10 Reed Switch Tie-rod Mounting Style D-A5/D-A6 For details about certified products conforming to international standards, visit us at www.smcworld.com.
PF2A ZS-36-A1 ZS-36-A2 ZS-36-A3 ZS-36-A4 ZS-36-A5 2 L-type brackets, 2 mounting screws M3 x 15L For 1 station (for single unit) 2 L-type brackets, 2 mounting screws M3 x 25L For 2 stations PF2W 2 L-type brackets, 2 mounting screws M3 x 35L For 3 stations 2 L-type brackets, 2 mounting screws M3 x 45L For 4 stations PF2D 2 L-type brackets, 2 mounting screws M3 x 55L For 5 stations IF 951 Series
'Some options lisH a5 "SpecislOrder" ilem6. Note 1) Use dry-air at low temperature.
C(D)U6-D Tightening Torque/ 36 (41) 40 (50) 44 (54) 48 (58) 52 (62) 56 (66) Bore size (mm) Hexagon socket head cap screw dia.
Q ' c : ' % l1 Series VQC1 000 : Base-Mou nted Type/Pl ug-in Un it O How to order manifolds wsQctt_TF wsQc11{U6 SeriesVQClooo. I Base-Mounted plug-in I I l : , 1 : K t t Requires for S kit "SDQ".
BBA1: For D-A5/A6/F5/J5 types Note 1) Refer to page 1055 for details on the BBA1. The above stainless steel screws are used when a cylinder is shipped with the D-F5BA auto switch. When only the auto switch is shipped independently, the BBA1 is attached.