(reed or solid state input) for 30 ms or longer 18 No.PF-OMU0002-D NPN + Analogue output type PF3A7H--ES/FSMaximum load current: 80 mA Internal voltage drop 2 V max.
Max. applied voltage: 30 V, Load current 80 mA Internal voltage drop: 1.5 V or less When used as a switch output device Max. applied voltage: 30 V, Load current 80 mA Internal voltage drop: 1.5 V or less -19No.PF-OMA1011-A PFG203-# IO-Link/PNP open collector 1 output + PNP open collector 4 output specification Used as IO-Link device Load current 80 mA Internal voltage drop: 1.5 V or less
L/min 0.01 L/min 0.1 L/min 1 L/min 2 L/min (50 ms) 0.05 L/pulse 0.1 L/pulse 0.5 L/pulse 1 L/pulse 2 L/pulse 090 () 070 ( ) L/minL 3F.S. 3F.S. 2F.S. 2 5%F.S.(25 ) 3 3 9.9 L 9 L 4 0.1L 0.5L 1L NPN PNP 80 mA DC28 V NPN1 V (80 mA ) PNP1.5 V (80 mA ) 25 0.5 s/1 s/2 s -65No.PF-OMM0004-D PF3W704 PF3W720 PF3W740 PF3W711 PF3W721 6 0.5 s/1 s/2 s 15 V 1 k 420 mA DC12 V 300 DC24
. -17No.PF-OMN0012-H Examples of Internal Circuit and Wiring NPN2 output type PNP2 output type PF3W30A PF3W30B Max. 28 V, 80 mA Internal voltage drop 1 V or less Max. 80 mA Internal voltage drop 1.5 V or less NPN + Analogue output type PNP + Analogue output type PF3W30C PF3W30E NPN + Analogue output type PNP + Analogue output type PF3W30D PF3W30F Max. 28 V, 80 mA Internal voltage drop 1 V
17: Pump capacity (HRSH150/200-A-20/40-HRSH150/200/250-W-20/40-) 8.5 Pump Capacity HRSH Series 8-18 HRX-OM-Q026 Chapter 8 Documents 8.5.3 HRSH250/300-A-20/400.9 90 0.8 80 Circulating fluid outlet 0.7 70 Lifting head [m] Pressure [MPa] 0.6 60 Usable flow rate range 0.5 50 0.4 40 0.3 30 Circulating fluid return 0.2 20 0.1 10 0 0 0 20 40 60 80 100 120 140 160 180 Circulating fluid flow [L/min
-32DB MHSH3-40DB MHSH3-50 DB MHSH3-63 DB MHSH3-80 DB mm 5 5 10 10 15 N 6~10 11~15 20~25 29~34 49~59 g 500 740 1,290 2,250 4,000 g 32 40 50 63 80 MHSHJ3-D 430 600 1,020 1,710 3,040 MHSHJ3-DA 550 800 1,380 2,360 4,120 MHSHJ3-DB 520 770 1,340 2,310 4,120 5 3. 3-1. 1 2 3 3-2. 1 .
Standard stroke (mm) Bore size 50 63 80 Extended 40.3 78.5 88.2 Retracted 139.5 174.6 217.3 Bore size Standard stroke 50 30 63 30 80 40 1-4. Cylinder mass Action Bore size Mass (mm) (kg) 50 1.70 Double acting Single acting (spring retraction) Double acting with spring 63 2.78 80 4.96 4 - 2.
V, 80 mA Residual voltage 1 V or less -B PNP 2 output type Max. 80 mA Residual voltage 1 V or less -18No.PS-OMM0003-J Pressure Setting Measurement mode The measurement mode is the condition where the pressure is detected and displayed, and the switch function is operating.
, 290 80 AM350 3 4 2B/FF/10K 11/2 B/FF/10K 1 2 3 4 , 305 312 80 AM450 AMl 1 1 1 2 1 3 4 1 2 , , , 339 80 AM550 Related poroducts 391 80 AM650 1 2 1 540.5 80 AM850 Precautions/With Differential Pressure Gauge(GD40-20-01) Be sure to read before handling.
AMD550 AMD650 AMD850 3/4B/FF/10K 1B/FF/10K 290 AMD350 80 Related poroducts 2B/FF/10K 11/2 B/FF/10K 305 312 AMD450 80 339 AMD550 80 391 AMD650 80 540.5 AMD850 80 Precaution Please refer to p.4.5-7 for with pressure differential gauge (GD40-2-01). 4.6-14
AMH650 AMH850 3/4B/FF/10K 1B/FF/10K 290 AMH350 80 2B/FF/10K 11/2 B/FF/10K 305 312 AMH450 80 339 AMH550 80 391 AMH650 80 540.5 AMH850 80 Precaution Please refer to p.4.5-7 for with pressure differential gauge (GD40-2-01). 4.6-21
Rc 1/8 Body ported 80 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 M5 x 0.8 130 (Without subplate 80) N.C. Base mounted (with sub-plate) SYJA724-01 SYJA724-02 N.O.
Material Description Pilot valve assembly M8 x 80 VFS6000-15 VFR61 VFS6000-15 VFR62 M8 x 80 VFS6000-15 VFR63/64/65 NBR Hexagon socket head screw Gasket o M8 x 80 Refer to How to Order Pilot Valve Assembly on page 3-5-94. Steel !0 !
, 100, 125, 160, 200, 250, 320, 400, 500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 2000 2000 2000 2000 2000 2000 32 40 50 63 80 100 125 Minimum Stroke for Auto Switch Mounting 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 25, 50, 80, 100, 125, 160
, 100, 125, 160, 200, 250, 320, 400, 500 40 1900 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 50 1900 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1900 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1900 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 1900 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 2000 125 Intermediate
or less 3 Exhaust center 1.87 (1.82) VFR540 VFR541 3 80 or less 1.87 (1.82) VFR551 Pressure center VFR550 3 80 or less Note 1) [ ]: Denotes the normal position.
100 120 140 160 180 200 0.1 0 40 60 80 100 120 140 160 180 200 20 20 Overhang L (mm) Overhang L (mm) MXJ Graph (19) Stroke: Up to 100 stroke Graph (15) Stroke: Up to 100 stroke MXP 20 20 10 10 MXY 3 4 5 3 4 5 40 Mass W (kg) Mass W (kg) MTS 40 2 2 32 32 1 1 25 20 0.5 0.4 0.3 0.5 0.4 0.3 25 20 16 16 0.2 0.2 12 12 0.1 0.1 0 40 60 80 100 120 140 160 180 200 20 20 0 40 60 80 100 120 140 160 180
Then, measure the flow rate, upstream pressure and downstream pressure each at 80%, 60%, 40% and 20% points of the flow rate. Calculate the sonic conductance C from the maximum flow rate. Also, substitute other data for variables in the formula for subsonic flow and obtain the critical pressure rate b by averaging the critical pressure rates at those points.
mA Internal voltage drop: 1 V or less (with load current of 80 mA) Maximum applied voltage: 30 V Maximum load current: 80 mA Internal voltage drop: 1 V or less (with load current of 80 mA) PNP open collector (PF2D201) Switch output (Real-time switch output, Accumulated switch output) Output Note 3) specifications Accumulated pulse output No. of outputs Output protection NPN open collector