Body Size: 40, Thread: N (NPT), Port: 06 (3/4), Option: Standard, Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 40, Thread: N (NPT), Port: 06 (3/4), Option: Standard, Attachment: V1 (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 40, Thread: N (NPT), Port Size: 06 (3/4), Option: Standard, Attachment: SV (S + V), Semi-Standard 1: 8 ( Metal Bowl w/Level Gauge), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 50, Model Type: A (Filter Regulator + Lubricator), Thread: N (NPT), Port Size: 06 (3/4), Float Type Auto Drain: w/o Auto Drain, Pressure Gauge/Digital Pressure Switch: w/o Pressure Gauge, Attachment: V (Mounting Position: AF + AFM + AR + V), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl Type + Lubricator: 8 (Metal Bowl w/Level Gauge), Bowl Guard: None, Air Filter Drain Port: w/Drain
Body Size: 5000, Port Thread: N (NPT), Port Size: 06 (3/4), Option: None, Voltage: 5 (24 VDC), Electrical Entry: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Flow Direction, Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 40, Thread: N (NPT), Port Size: 06 (3/4), Option: Standard, Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Style: Pressure Switch with Piping Adapter, Body Size: 50 (AC40-06), Thread Type: N (NPT), Port Size: 06 (3/4), Set Pressure Range: 6 (0.1 to 0.6 MPa), Lead Wire Length: L (3m), Pressure Unit of the Scale Plate: MPa, Mounting: Right
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation
Body Size: 40, Back Flow: w/o Backflow Function, Thread: N (NPT), Port Size: 06 (3/4), Mounting: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Pressure Units: Z (Unit on Product Label: psi, °F, Pressure Gauge: MPa/psi Dual scale)
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation
Body Size: 40, Back Flow: w/o Backflow Function, Thread: N (NPT), Port Size: 06 (3/4), Mounting: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: N (Non-relieving Type), Flow Direction: Left to Right, Pressure Units: Z (Unit on Product Label: psi, °F, Pressure Gauge: MPa/psi Dual scale)
Micro mist separator series AFD is available in 3 sizes; 1/4 (20), 3/8 (30) & 1/2 (40). Rc(PT), PF & NPT threads are available. Port sizes range from 1/8 to 3/4. Accessories include bracket, float type auto drain, and differential pressure type auto drain. Modular type micro mist separator , Thread types: Rc(PT), NPT, G(PF) , Body sizes available: 1/8, 3/8, 1/2 , Port sizes available
Body Size: 40, Model Type: D (Filter Regulator + Mist Separator), Thread: N (NPT), Port Size: 06 (3/4), Float Type Auto Drain: w/o Auto Drain, Pressure Gauge/Digital Pressure Switch: w/o Pressure Gauge, Attachment: V1 (Mounting Position: V + AF + AR*K), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl Type + Lubricator: Standard (Polycarbonate Bowl + Lubricator), Bowl Guard: None, Air Filter
The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Pressure relief, 3 port valve, Accessory for AC series, Body sizes:
Body Size: 40 (Applicable AC Size: AC40), Handle Operation: W (Double Action), Thread Type: N (NPT), Port Size: 06 (3/4), Mounting: B (w/Bracket), Silencer: S (w/Built-in Silencer, EXH Port), Handle Color: Red, Handle Material: M (Metal), Flow Direction: Flow Direction: Left to Right), Unit: Z (Unit of Product Label: psi)
Body Size: 50 (Applicable to AC50/AC60), Handle Operation: W (Double Action), Thread Type: N (NPT), Port Size: 06 (3/4), Mounting: B (w/Bracket), Silencer: S (w/Built-in Silencer, EXH Port), Handle Color: Red, Handle Material: M (Metal), Flow Direction: Flow Direction: Left to Right), Unit: Z (Unit of Product Label: psi)
Body Size: 50 (Applicable to AC50/AC60), Handle Operation: W (Double Action), Thread Type: N (NPT), Port Size: 06 (3/4), Mounting: without Mounting Option, Silencer: S (w/Built-in Silencer, EXH Port), Handle Color: Red, Handle Material: M (Metal), Flow Direction: Flow Direction: Left to Right), Unit: Z (Unit of Product Label: psi)
Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 40 (5~40L/min), Return Unit: None, Thread: N (NPT), Port Size: 06 (3/4), Flow Switch Output: 2T (Remote Sensor Unit; Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None, Temp. Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (without Lead Wire), Flow Switch Unit: G (Remote Sensor Unit; Instantaneous Flow: L/min, (gal/min);
Flow Switch Type: Remote Sensor Unit, Rated Flow Range: 5~40L/min, Return Unit: None, Thread: NPT, Port Size: 3/4, Flow Switch Output: Remote Sensor Unit; Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None, Temp. Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: without Lead Wire, Flow Switch Unit: Remote Sensor Unit; Instantaneous Flow: L/min, (gal/min); Accumulated Flow: None; Temp:
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation