The connection may be a 1/8 inch NPT female thread or 10-32 female thread or M5 depending on the valve model. 3. After installation, check internal leakage (leakage across seat) with inert gases. Perform a helium leak test depending on applications. Maintenance Warning 1. If a valve requires repair, contact SMC. Operation (Air operate type) Warning 1.
14 16.5 1.0 Allowable moment coefficient 0.7 0.5 Note) For A, A, A and A, there is no difference in the corrected values due to the stroke.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
B Model A B VNH211 -15A A B VNH311 -20A A B VNH411 -25A A B VNH113 -10A A B VNH213 -15A A B VNH313 -20A A B VNH413 -25A A B VNH133 -10A A B VNH233 -15A A B VNH333 -20A A B VNH433 -25A VNH111 -10A Operating fluid pressure Fluid Operation Operating fluid temperature 0 to 3.5 MPa Coolant External pilot solenoid/Air operated 5 to 60C /5 to 60C (NBR seal) 5 to 60C /5 to 99C (FKM seal) 0 to 7.0
This may result in a reduction in flatness. Storage Caution When mounting to equipment, use M5 hexagon socket head bolts, and fix the adsorption plate on a surface with a high degree of flatness. Mounting on a surface with a low degree of flatness may result in a reduction in flatness of the adsorption surface. Store in a normal indoor environment.
Set value P_1 Hysteresis H_1 Pressure Piping Tightening the connection thread For connecting to the body (piping specification: -M5) After hand tightening, apply a spanner of the correct size to the spanner flats of the piping body, and tighten with a 1/6 to 1/4 rotation. As a reference, the tightening torque is 1 to 1.5 Nm.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
Zero-clear function In measurement mode, when the and buttons are pressed for 1 second or Piping Tightening the connection thread For connecting to the body (piping specification: -M5) After hand tightening, apply a spanner of the correct size to the spanner flats of the piping body, and tighten with a 1/6 to 1/4 rotation. As a reference, the tightening torque is 1 to 1.5 Nm.
Option Applicable model 10-/21-AF20-A 10-/21-AF30-A 10-/21-AF40-A 10-/21-AF40-06-A 10-/21-AF50-A 10-/21-AF60-A Bracket assembly Note 2) AF52P-050AS AF22P-050AS AF32P-050AS AF42P-050AS AF42P-070AS Note 2) Assembly includes a bracket and 2 mounting screws. 1069-1 A Air Filter 1021-AF-A Dimensions AF20-A AF30-A to 40-06-A 10211021T N S J M U D J M U D S N T Air Preparation Equipment Pressure
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty.
ECC-PNAL-20MT-D ECC-PNAL-20MR-D ECC-PNAL-20MR-A ECC-PNAL-10MT-D ECC-PNAL-10MR-D ECC-PNAL-10MR-A ECC-PNAL-6MR-A Please Note: 1) All PneuAlphas need to be connected to a power supply. 4/2 : 6/4 : 12/8 suitable to their rated voltage specifications. 2) Stand alone controllers can be programmed from the 8 front panel function keys. 3) All Pneu Alpha controllers have a CD-ROM supplied giving
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
Accessory Function plate for VO307 (D sealing, with thread): DXT152-14-5A 628 A VNH Series High Pressure Coolant Valve 3.5 MPa, 7.0 MPa Specifications 3 port valve 2 port valve A B Model A B VNH211 -15A A B VNH311 -20A A B VNH411 -25A A B VNH113 -10A A B VNH213 -15A A B VNH313 -20A A B VNH413 -25A A B VNH133 -10A A B VNH233 -15A A B VNH333 -20A A B VNH433 -25A VNH111 -10A Operating fluid
Take safety measures (e.g. mounting protective covers) when there is a danger of fingers being caught in a gripper or workpieces causing damage, etc. 3. There is a danger of workpieces dropping if there is a decrease in gripping force due to a drop in circuit pressure caused by a power failure or trouble with the air source.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
(2) NC / Analog output 54 44 34 Blue (3) DC() Use this sensor by connecting to P/A remote type display unit Series PF2A3. 4-4.5 2-Port size 30 40 50 Connector pin numbers 2 1 (43.5) A 4 3 (mm) A B Output specification Pin no.
Please note that the graph should only be used as a guide, as there is a tolerance of about 10% in the clamp cylinder body.
Adjust the stopping time by using a stopper nut. Control the stopping time of the impacting material by turning the stopper nut in or out (thus changing length a). After establishing the stopper nut position, use a hexagon nut to secure the stopper nut in place. Capacity of shock absorbers deteriorate in accordance with usage.
) 4 3.2 () 5 4 () 24 - No.ZQ-OM01401-B ZS-39-5G ZQ1-LW6-N-A 1) N NPN P PNP (1) 3 Assy ZQ1-PL11-A 4 Assy ZQ1-FC1-A 5 (10 ) ZQ1-FE2-A 6 ZQ1-CV 7 V VVQ1000-50A-C4 (1) 50A-M5 (M5x0.8) (1) 50A-C3 3.2 () 50A-C4 4 () 8 (10 ) 50A-C6 6 () ZK1-CP-A F1-LC3 3.2 () F1-LC4 4 () 9 Assy ZQ1-BK1-A 25 - No.ZQ-OM01401-B 7.3 b a a a 1. (2 ) 2.
Set value P_1 Hysteresis H_1 Pressure Piping Tightening the connection thread For connecting to the body (piping specification: -M5) After hand tightening, apply a spanner of the correct size to the spanner flats of the piping body, and tighten with a 1/6 to 1/4 rotation. As a reference, the tightening torque is 1 to 1.5 Nm.