Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): None, The number of the switches: None, Specification: Built-in strong magnet type, Clamp Side Lock: With lock, Mounting surface position: Position C, Port Screw Type: G, Guide Pin Diameter
Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P79WSE, Lead Wire Length(m): 0.3, The number of the switches: 2 pcs., Specification: Built-in strong magnet type, Clamp Side Lock: With lock, Mounting surface position: Position C, Port Screw Type: NPT, Guide Pin Diameter: ø15.9, Guide Pin Shape
Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): None, The number of the switches: None, Clamp Side Lock: Without lock, Mounting surface position: Position C, Port Screw Type: Rc, Guide Pin Diameter: ø19.7, Clamp Arm Position: 180° from
Pressure(MPa): 1, Additional Function: No (Standard), Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: P79WSE, Lead Wire Length(m): 0.3, The number of the switches: 2 pcs., Clamp Side Lock: Without lock, Mounting surface position: Position C, Port Screw Type: Rc, Guide Pin Diameter: ø19.7, Clamp Arm Position: 180° from port, Clamp Position Height
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: M5, Body Options
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options
Value 7 6 5 4 3 2 1 0 Value 7 6 5 4 3 2 1 0 Output No. 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 1 0-7 All clear output Setting value 00 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 Output No. 15 14 13 12 11 10 9 8 15 14 13 12 11 10 9 8 2 8-15 All hold last state Setting value FF 1 1 1 1 1 1 1 1 00 0 0 0 0 0 0 0 0 Output No. 23 22 21 20 19 18 17 16 23 22 21 20 19 18 17 16 3 16-23 All force output Setting value
When embedded O-ring Air Machining dimensions for mounting Sealed with O-ring Air Bore size (mm) Stroke A B C D E F G 5 12 8.5 6 4 3.5 M8X1.0 6.5 3 10 20 16.5 14 15 28 24.5 22 5 16 12.5 10 6 3.5 M10X1.0 8.5 3 10 23 19.5 17 15 30 26.5 24 5 17 13.5 10.5 10 3.5 M15X1.5 12 4 10 23.5 20 17 15 30.5 27 24 5 19 14.5 11.5 16 4.5 M22X1.5 19 5 10 25 20.5 17.5 15 31.5 27 24 Note) E and F should be machined
When operating at temperatures below 5o C, water in the circuit may freeze and cause breakage of seals or malfunction. Corrective measures should be taken to prevent freezing. Operable temperature range is -10 to 60 deg.C (No freezing). Use the product within this range.
No.EX-OME0003-H PRODUCT NAME SI unit for DeviceNet MODEL / Series / Product Number EX250-SDN1 EX250-SDN1-X102 Table of Contents Safety Instructions 2 Product Summary 8 Model indication and How to Order 9 Summary of Product parts 9 Mounting and Installation 10 Installation 10 Wiring 11 Indication and Settings 17 DeviceNet objects 23 Maintenance 33 Troubleshooting 34 Specification 42 Specifications
Mounting/ Piping Equivalent tightening torque [Nm] KF 04 1.5 to 2.0 2 to 7 KF 06 1.5 to 2.0 3 to 8 KF 08 1.5 to 2.0 4 to 9 KF 10 1.5 to 2.0 6 to 9 KF 12 1.5 to 2.0 9 to 12 KF 04 1.5 2 to 4 KF 06 1.5 4 to 6 KF 08 1.5 6 to 9 KF 10 1.5 10 to 12 KF 12 1.5 10 to 12 Sleeve material Fitting size Appropriate tightening rotations Nylon 66 C2700 2.
Supply DC24 V+10%/-5% to the power supply for control and inputs of the product.
ZS-10-A With lead wire ZS-10-5ANote) When ordering switch with 5 m long lead wire, indicate both part numbers. Lead wire length Caution 0.6 m Nil Ex.) ZSE2-01-15CN1 pc. ZS-10-5 A-501 pc.
Bore size 6, 10, 15 Type M thread Rc NPT G Symbol BS Nil Shock Absorbers 20, 25, 32, 40 TN TF Type Bore size (mm) 25 32, 40 10, 15 20 6 Standard (shock absorber RB series) Magnetic holding force Refer to page 1517 for specifications.
160C (40 to 71C) (No freezing) 1) 0.07 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 2) 4 x 10-9 Pam3/sec 2) Ra max 10 in. (0.25 m) Option: 7 in. (0.18 m), 5 in. (0.13 m) Face seal, Tube weld 0.20 psig (0.0014 MPa) rise in delivery pressure per 20 psig (0.14 MPa) source pressure drop Bottom mount 0.19 in3 (3.1 cm3) 0.99 lbs (0.45 kg) 3) Delivery pressure Gas Source pressure Proof pressure (Inlet)
How to Order Bore size 10 16 10mm 16mm Standard stroke (mm) 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes other than the above are produced upon receipt of order.
PF2A750 B 5 50 PF2A711 C 10 100 PF2A721 D 20 200 PF2A751 E 50 500 -37No.PF-OMO0007CN PF2A710/750 PF2A711/721/751 -38No.PF-OMO0007CN ()ZS-37-A (L )ZS-37-B ZS-29-T -39No.PF-OMO0007CN NPN(1 ) + (15 V) NPN(1 ) + (420 mA) PNP(1 ) + (15 V) PNP(1 ) + (420 mA) 10 PF2A7 NPN(1) + (15 V) PF2A7--28--X560 PNP(1) + (15 V) PF2A7--68--X560 NPN(1) + (420 mA) PF2A7--29--X560 PNP(1) + (420 mA) PF2A7