SMC Corporation of America
Elite Part Number Search
Search Results "GP46-10-01L2-C"

Cooling capacities: 2kW, 4kW, 8kW, 10kW; Circulating Fluid: 60% ethylene glycol aqueous solution; Temperature range setting: -10 to 90°C (2kW), -20 to 90°C (4, 8, 10kW); Temperature stability: ±0.1°C; Power supply requirement: 3-phase 200 VAC/50Hz or 3-phase 200~208 VAC/60Hz; Standards: CE, UL, RoHS, SEMI S2, S8, F47

No.SFOD-OML0002-A PRODUCT NAME Handheld Electrostatic Meter MODEL/ Series IZH10 Table of Contents Safety Instructions 2 Model Indication Method 6 Summary of Product parts 7 Definition and terminology 8 Assembly 9 Setting / Adjustment 10 Procedure 10 Function settings 11 Troubleshooting 14 Specification 17 Specifications 17 Characteristics graph (for reference) 17 Dimensions 18 -1No.SFOD-OML0002

INR-244-831 3-1 Communication Format 3.3 Composition of Required Message (from master to the product) Refer to page 3-4 3.5 Explanation of Code for codes 1 to 10.

Correlation between input number and Input Block The total number of Input and Output blocks can not exceed 10. The maximum input point is 32.

When making drain exhaust piping, use piping with bore size 10 or larger than 10. Length should be shorter than 5m.

Seal kit includes a grease pack (10 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g) 32 Piston gasket 33 #4 #5 #6 #7 #8 #9 $0 Tube rod gasket 30, 31, 32 and 33 are non-replaceable parts, so they are not included in the seal kit.