SMC Corporation of America
Elite Part Number Search
Search Results "CY3R32-600-M9PSBPC"

(Atlanta) 1440 Lakes Parkway, Suite 600 Lawrenceville, GA 30043 Tel: (770) 624-1940 FAX: (770) 624-1943 16850 W. Victor Road New Berlin. Wl 53151 Tel: (414) 827-0080 FAX: (414) 827-OO92 5377 Glen Alden Drive Richmond, VA 23231 Tel: (804) 222-2762 FAX: (80a) 222-5221 SMC Pneumatics Inc.

(Atlanta) 1440 Lakes Parkway, Suite 600 Lawrenceville, GA 30043 Tel: (770) 624-1940 FAX: (770) 624-1943 16850 W. Victor Road New Berlin. Wl 53151 Tel: (414) 827-0080 FAX: (414) 827-OO92 5377 Glen Alden Drive Richmond, VA 23231 Tel: (804) 222-2762 FAX: (80a) 222-5221 SMC Pneumatics Inc.

Thomas Oil-less Linear Diaphragm Compressor / Vacuum Pump, 12v/50Hz Flow Rate: .95 LPM , .95 LPM, Max Pressure: 8.7 PSIG / 241 in H20 / 600 mbar , 8.7 PSIG / 241 in H20 / 600 mbar, Max Vacuum: 5.9 in HgV / -200 mbar , 5.9 in HgV / -200 mbar, Voltage (50 Hz): 12, Frequency (Hz): 50, Phase: 1-phase, Item Dimensions: Length: 2.83 in / 72 mm Width: 2.09

The CNA2 series cylinder with lock?is?suitable for mid-stroke stops, emergency stops, and drop prevention. An equal holding force in extending and retracting directions make it possible to lock at either end of the stroke. High reliability and stable holding force are maintained by using a substantially lengthened brake shoe with superior wear resistance. The locking mechanism is isolated

CYLINDER ROTARY CLAMP MKA/MKB CLAMP CYLINDER. MK-Z ROTARY CLAMP. ACTUATOR. 25MM MKA/MKB DBL-ACT AUTO-SW. 1.09881 lb. IE.

Bore Size: 16mm, Port Thread: Rc, Stroke: 75mm, Adjuster: A (Both Sides Adjusters), Function: Standard, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SBPC (0.5m Cord Length, M8-4 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Adjuster: X12 (25mm)

Magnet: D (Built-in Magnet), Series: J2W, Mounting: B (Basic Style), Bore Size: 16mm, Stroke: 60mm, Cushion: Rubber Bumper, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SBPC (0.5m Cord Length, M8-4 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 mm, Stroke: 15 mm, Rod End Thread: B (Without Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: SBPC (0.5m Cord Length, M8-4 Pin Connector)

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: Air cushion on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Magnet: Built-in Magnet, Series: J2W, Mounting: Basic Style, Bore Size: 16mm, Stroke: 60mm, Cushion: Air Cushion, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-4 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Rail Mounting

Magnet: Built-in Magnet, Series: J2W, Mounting: Basic Style, Bore Size: 16mm, Stroke: 60mm, Cushion: Air Cushion, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-4 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting

Magnet: Built-in Magnet, Series: J2W, Mounting: Basic Style, Bore Size: 16mm, Stroke: 60mm, Cushion: Rubber Bumper, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-4 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, ROTARY ACTUATOR, AUTO-SW, ACTUATOR, CRQ2 ROTARY ACTUATOR, KE, 30MM CRQ2 DBL-ACT AUTO-SW, 2.42508 lb

Series: NCDA1 (Standard w/ Magnet), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 325 (3 1/4"), Stroke: 3000 (30"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SBPC (0.5m Cord Length, M8-4 Pin Connector

Series: NCDA1 (Standard w/ Magnet), Mounting: U (MT1, Rod Trunnion), Bore Size: 400 (4"), Stroke: 2400 (24"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: IM (Intermediate Male, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SBPC (0.5m Cord Length, M8-4 Pin Connector)

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9P, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: G, Auto

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,