AS121FM-M5-23 AS121FM-M5-04 AS121FM-M5-06 AS221FM-01-23 AS221FM-01-04 AS221FM-01-06 AS221FM-01-08 AS221FM-02-04 AS221FM-02-06 AS221FM-02-08 AS221FM-02-10 3.2 4 6 3.2 4 6 8 4 6 8 10 22.1 22.1 22.9 27.5 27.5 27.5 32.4 34.4 34.4 36.4 43.2 8.4 9.3 11.6 9.3 9.3 11.6 15.2 10.4 12.8 15.2 18.5 17.3 17.3 18.1 20.4 20.4 20.4 25.3 25.2 25.2 27.2 33.9 12.7 12.3 7 25.1 28.8 30.1 9.6 33.8 M5 x 0.8 8 13.5
P . 15-11-3 15-9-2 2 Speed Controller with One-touch Fitting Elbow Type/Universal Type Series AS How to Order 2 2 0 01 06 S AS 1F Nil Option Body size 1 2 3 4 M3, M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard None With seal Hexagonal lock nut Electroless nickel plated S K N If more than one option is required, write option part numbers in the order of S, K, N.
As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
Example: In case of 6 stations of air suction filter ZFA100-01 ZZFA1-06 1 pc. (Brackets for 6 stations) ZFA100-01 6 pcs.
As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
Body class Applicable model Body class SRF10 SRF30 SRF50 Applicable model SRF10 SRF30 SRF50 Symbol Body class 03 04 05 06 07 06 08 10 07 11 12 13 19 1/8" 4 3/16" 6 1/4" 6 8 10 1/4" 3/8" 12 1/2" 3/4", 19 2 3 5 2 3 5 2 Type of parts Symbol U B N Parts 3 Nut + Insert bushing Insert bushing Nut 5 Note) For details about fitting parts, refer to Best Pneumatics No. 9. 888 Applicable Fluids The
(A) 2 0.7MPa (101psi) 0.15MPa (22psi) 1.8 (0.1) 10HZ 3 (R) 1 (P) 3 (R) 1 (P) Refer to Best Pneumatics (1) Page 2.2-1 Mist Separator Series AM Specifications Models Model Compressed air 1.0MPa (145psi) 0.05MPa (7psi) Fluid AM150 AM250 Maximum operating pressure Rated flow rate (ANR) 300l/min (10.5SCFM) 750 l/min (26.5SCFM) Note 1) Series AM separates and removes the oil mist in compressed
(A) 2 0.7MPa 0.15MPa 1.8 (0.1) 10HZ 3 (R) 1 (P) 3 (R) 1 (P) Refer to Best Pneumatics (1) Page 2.2-1 Mist Separator Series AM Specifications Models Model Compressed air 1.0MPa 0.05MPa Fluid AM150 AM250 Maximum operating pressure Rated flow rate l/min (ANR) 300 750 Note 1) Series AM separates and removes the oil mist in compressed air which is troublesome for ordinary filters, and removes fine
Series VXF How to Order VXF 2150 06 1 G Solenoid type Normally closed VXFA 2150 06 Air operated type Option Nil S Standard With silencer Refer to the table (2) below for availability.
VVPA4 5 0 04 04 1 Thread type Nil Rc G NPT NPTF VP 5 port Air operated manifold F N T 5 Base size Rc A, B Port size Rc 3 4 6 1 VVPA450 Symbol 04 Port size VVPA460 1 2 3 4 Mixed 1 06 10 M (2) Piping Note 2) In the case of mixed specifications, indicate M and specify port location sparately on a manifold specification sheet.
A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8
AS121FM-M5-23 AS121FM-M5-04 AS121FM-M5-06 AS221FM-01-23 AS221FM-01-04 AS221FM-01-06 AS221FM-01-08 AS221FM-02-04 AS221FM-02-06 AS221FM-02-08 AS221FM-02-10 3.2 4 6 3.2 4 6 8 4 6 8 10 22.1 22.1 22.9 27.5 27.5 27.5 32.4 34.4 34.4 36.4 43.2 8.4 9.3 11.6 9.3 9.3 11.6 15.2 10.4 12.8 15.2 18.5 17.3 17.3 18.1 20.4 20.4 20.4 25.3 25.2 25.2 27.2 33.9 12.7 12.3 7 28.8 25.1 30.1 9.6 33.8 M5 x 0.8 8 13.5
A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8
A Note 1) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12
A Note 1) 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12
Flow Rate Characteristics Construction XT13-394-06, 10 Max. operating flow rate It is recommended to be used within the max. operating flow rate (negative) range. ( ) Conditions/ Inlet pressure: 0.5 MPa, Fluid: Water 0.5 82 SMC Outlet pressure MPa 0.4 K P C U O S H L 0.3 0.2 82 0.1 0.0 10 20 30 40 50 60 70 0 Flow rate L/min (ANR) w INA-48-1-06, 10 142 (Max. 146) Conditions/ Inlet pressure
Port size 04 06 10 12 14 20 LVH 1 2 3 4 Refer to page 17-3-16 for ordering coil only. 1 1 1 2 LVD 1 4 1 2 Thread type Nil T F N LVQ Rc NPTF G NPT Refer to the table (1) given below for availability.
BA4-040 BA4-063 BA4-080 BA4-080