VACUUM GENERATOR, VACUUM EJECTOR, M18, 99 lb
VACUUM GENERATOR, VACUUM EJECTOR, M18, 109 lb
VACUUM GENERATOR, VACUUM EJECTOR, M18, 99 lb
Vacuum Ejector, VACUUM EJECTOR, 99 lb
VACUUM GENERATOR, VACUUM EJECTOR, M18, 113 lb
VACUUM GENERATOR, VACUUM EJECTOR, M18, 113 lb
VACUUM GENERATOR, VACUUM EJECTOR, M18, 104 lb
VACUUM GENERATOR, VACUUM EJECTOR, M18, 104 lb
Vacuum Ejector, VACUUM EJECTOR, M18, 99 lb
Vacuum Ejector, VACUUM EJECTOR, M18, 85 lb
VACUUM GENERATOR, VACUUM EJECTOR, M18, 113.00000 lb
System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Inch Size
System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Inch Size
System/Body: Ejector System, for Manifold, Individual Port Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: Common Wiring, Plug-in for Manifold,
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)
Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)