position 4-5.5 mounting hole Handle Operated Type VBA2100-03, VBA4100-04 Pressure gauge (Option) IN port OUT port 4-12 mounting hole E D Silencer (Option) EXH port: 1 position EXH port: 1 position D 73 116 O 39 56 A 300 404 B 170 207.5 C 53 96 E 118 150 F 98 130 G 46 62.8 H 43 62 I 60.5 90 J 18 17 K 15 15 L N Rc 1/16 Rc 1/8 M 31 40 Model Port size Rc 3/8 Rc 1/2 VBA2100-03 VBA4100-04 20 14
size (Rc, NPT, G) 3/8 1/2 1/8, 1/4 Note 1) The system accuracy when combined with PF2A3.
2 1/8, 1/4 Note 1) The system accuracy when combined with PF2A3.
Note) A M5 01 02 02 03 04 04 06 10 10 12 14 20 Note) M5 1 8 1 4 1 4 3 8 1 2 1 2 3 4 1 Note) Note) 3 Body ported 5 1 1 11 4 7 1 4 11 2 1 2 2 9 Note) Only bracket or foot may be mounted. 14-10-2 3 E-P HYREG Series VY1 Standard Specifications 02 03 04 04 06 10 02 03 04 VY1A0 0 1-M5 VY1B0 0 1M 0 5 1 VY110 0 10 0 1 2 VY120 0 10 0 1 2 VY130 0 1VY140 0 1VY150 0 1VY170 0 11 1 0 2 VY190 0 11 2 4
1 Speed Exhaust Controller Series ASV Size: M3, M5, 1/8, 1/4, 3/8 How to Order Integration of a quick exhaust valve and an exhaust restrictor permits high-speed cylinder operation. 3 1 0 F 01 06 ASV S K Speed exhaust controller Option Nil None The effective area is two times larger.
/$($* # # $0( , $0(1 2 # $)' , $)'1 )'% -.!/(%$* # # $'( , $((1 2 # $$' , 3'1 '4( PB !! / # # & , # # -.!/(% 17-3-71 2 The VX series will be revised shortly. Series VXF How to Order VXF 2150 06 1 G Solenoid type Normally closed VXFA 2150 06 Air operated type Option Nil S Standard With silencer Refer to the table (2) below for availability.
Body size 3 4 5 6 1 Pressure gauge 8 3 ARX 1 2 None With pressure switch Nil S None Adapter assembly 4 3 1/4 3/8 1/2 3/4 1 AMR AMR Port size Thread type Thread type ARM Symbol Port size Nil N F Nil N G Rc NPT G Rc NPT G 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the port size of the body.
Left IN1(P) Piping VHS500-06 VHS501-06 VHS400-04 VHS401-04 VHS400-03 VHS401-03 VHS400-02 VHS401-02 Right IN1(P) 3 4 1 2 3 8 1 4 Port size Effective area (mm2)(CV) Weight (kg) 93(5.22) 57(3.20) 35(1.97) 21(1.18) 105(5.90) 76(4.27) 54(3.03) 35(1.97) 0.29 1(P)2(A) 2(A)3(R) 0.34 0.25 0.27 Left or right to the front face of the handle.
-06-08-01S-3 33 80 83 84 17 20 15.5 12.8 45.4 17 11.1 18.5 76.5 77 78 41 6 KM14-06-08-02S-3 15.2 12.8 KM14-06-08-03S-3 1 4 3 8 1 2 10 6 KM14-06-10-02S-3 44 45 67 7.5 KM14-06-10-03S-3 18.5 12.8 KM14-06-10-04S-3 87.5 88.5 92 81.5 82 84 19 22 21 19 12.8 45.4 17 12.8 21 1 4 3 8 1 2 10 8 KM14-08-10-02S-3 48 88 89 90.5 94 95 98.5 19 71 7.5 KM14-08-10-03S-3 18.5 15.2 KM14-08-10-04S-3 22 22.5 19
Calculation of diaphragm life Example 1) Discharge rate 5l/min, when operating 8h/D (for PAX1000) 5 0.021 238 (cycles/min) = = Cycles per minute Discharge rate Discharge per cycle 1 60 = x x 1 8 (daily operating time) Reference life cycles Cycles per minute Service life 1 60 = 1 8 50,000,000 238 x x 437 days = Example 2) Discharge rate 5l/min, when operating 8h/D (for PA3000 automatically
(mm) Model Model Accessory TM-04 TM-06 TM-08 2 x 6 TM-04 TM-06 TM-08 TM-10 TM-12 4 6 8 10 12 2.6 x 8 4 TM-10 3 x 8 TM-12 Dimensions: Multi-tube Holder N x D (Pitch) N x holding part Cutting groove for separation N (No. of holding parts) Applicable tubing O.D.
Metric size Inch size 3 4 5 6 1/8 standard 1/4 standard 3/8 standard 1/2 standard 07 09 11 13 06 08 10 12 1/4" 5/16" 3/8" 1/2" 6 8 10 12 Type Port size 3 Universal Symbol 01 02 03 04 F02 F03 F04 N01 N02 N03 N04 Pilot port M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/4 G 1/8 G 1/8 G 1/4 10-32 UNF NPT 1/8 NPT 1/8 NPT 1/4 Cylinder side R 1/8 R 1/4 R 3/8 R 1/2 R 1/4 R 3/8 R 1/2 NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2
01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" -X214 Restrictor (Without check valve) 04 4 06 6 08 8 10 10 12 12 With One-touch fittings Example) AS2002F-04A-X214 10Clean Series Example) 10-AS2002F-04A 1 For selecting applicable tubing O.D., refer to the Model shown above. 2 Use 1/8" tubing. *1 Fluorine grease is used. *2 The cleanliness class (ISO class) is 5.
SMC Corporation R&D Center Product Development Division-6 Address: 4-2-2, KINUNODAI,TSUKUBAMIRAI-CITY , IBARAKI-KEN 300-2493, JAPAN Phone:+81-297-52-6 Fax:+81-297-20-5007 E-mail:kaihatsu_6_g3@smcjpn.co.jp Notice: The content of this manual can be revised without a previous notice. ii HEF002-A6 Contents Contents 1 PREPARATION FOR COMMUNICATION -1-1 2 OPTIONS OF COMMUNICATION METHOD -2-1 2.1
SMC Corporation R&D Center Product Development Division-6 Address: 4-2-2, KINUNODAI,TSUKUBAMIRAI-CITY , IBARAKI-KEN 300-2493, JAPAN Phone:+81-297-52-6 Fax:+81-297-20-5007 E-mail:kaihatsu_6_g3@smcjpn.co.jp Notice: The content of this manual can be revised without a previous notice. ii INR-244-831 Contents Contents 1 PREPARATION FOR COMMUNICATION -1-1 2 OPTIONS OF COMMUNICATION METHOD -2-1
-06 AC4040 Model AC2040 AC3040 AW2000 AFM2000 AW3000 AFM3000 Proof pressure Component devices Filter regulator Mist seperator 1.5 MPa 1.0 MPa 0.05 MPa 0.05 to 0.85 MPa Max.operating pressure Minimum operating pressure 1/4 3/8 1/8 1/4 Port size Rc Regulating pressure range Rated flow rate (l/min (ANR)) (1) Pressure gauge port size Rc 1/8 1/8 150 330 800 800 Refer to Best Pneumatics Vol. 14
switch types> D-A7/A8, D-A7H/A80H, D-A73C/A80C, D-C7/C8, D-C73C/C080C, DE7A/E80A, D-Z7/Z8, D-9/9A, D-A9/A9V, and D-A79W type The above auto switches do not have internal contact protection circuits. 1.
) D-F5NT 1 10 25 30 D-Y59l D-Y7P D-Y7lW D-Z7l D-Z80 2 (Different surfaces, same surface) 1 15 n 15 + 40 (n 2) 2 (n = 2, 4, 6, 8) Note 1) Note 1) When n is an odd number, an even number that is one larger than this odd number is used for the calculation.
, D-A9V D-M9, D-M9V D-F9W, D-F9WV 5 5 5 1 pc. 10 5 10 2 pcs.
same surface) 1 15 10 D-A5m D-A6m n 15 + 55 (n 2) 2 (n = 2, 4, 6, 8)*1 10 + 55 (n 2) 2 (n = 2, 4, 6, 8)*1 2 (Different surfaces, same surface) 1 20 15 D-A59W n 20 + 55 (n 2) 2 (n = 2, 4, 6, 8)*1 15 + 55 (n 2) 2 (n = 2, 4, 6, 8)*1 2 (Different surfaces, same surface) 1 25 20 D-F5NTL n 25 + 55 (n 2) 2 (n = 2, 4, 6, 8)*1 20 + 55 (n 2) 2 (n = 2, 4, 6, 8)*1 D-Y59m D-Y7P D-Y7mW D-Z7m D-Z80