SMC Corporation of America
Elite Part Number Search
Search Results "VV317-02-103-02F"

= 2 x 9.8 x 30 x 103 = 0.59 (Nm) 1 3 1 3 MY3A MY3B M3E = x FE x Y = x 82.3 x 30 x 103 Load factor 3 = M2/M2 max = 0.59/1.6 = 0.37 = 0.82 (Nm) Load factor 5 = M3E/M3E max = 0.82/2.9 = 0.28 MY3M M2 Sum and Examination of Guide Load Factors 5 = 1 + 2 + 3 + 4 + 5 = 0.89 1 The above calculation is within the allowable value, and therefore the selected model can be used.