[Dustproof filter set] q This dustproof filter is secured with hook-and-loop tape.
L1 L2 L3 L4 L5 L6 L7 L8 D Model Bore size ASS AS2000-01 AS2000-02 AS3000-02, 03 1 8 Rc Rc Rc , 40 40 56 30 30 45.5 5 5 5.25 17 23 25 10 11.5 13.2 15.5 17 20.6 54.5 56 68 50 51.5 61 16 20 26 4.5 4.5 5.5 1 4 1 4 ASR Effective thread depth 6 8 3 Dimensions: AS5000 ASF 2-1/4 to 1/2 2-M4 x 0.7 Effective thread depth 7 15-9-31
How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area (mm) P: Differential pressure (P1P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures
AP100 (13) Working principle When the MR units OUT side pressure is applied to piston q , piston q moves until it balances with the force of pressure adjustment spring w . The movement of piston q is detected by switch assembly e and outputs ON and OFF signals.
How to Order Type 40 1(P) port Stations VV5Z3 05 40 2 M5 Rc 1/8 4(A), 2(B) port size 1(P), 3/5(R) port thread type 02 2 stations 3, 5(R) port M5 M5 x 0.8 Nil Rc 4(A), 2(B) port Rc 1/8 F G 20 20 stations M5 x 0.8 N NPT Z NPTE How to Order Type 41 VV5Z3 05 41 1 M5 Applicable solenoid valve Stations 4(A), 2(B) port size 1(P), 3/5(R) port thread type 3/5(R) port 02 2 stations G L M D G L M
Poriing No. of Ports 'xx" M84010-02 Ta"NPTFSide l l M84011-02 7a" NPTF Side: Y.r" Bottom A & B 1 3 MB 4210-02 %"NPTFSid(2); % Botlom(5) 7 t 5 Manifolds *(OptionsT & P Only) Part No. Poding No.of Ports "xx" Subplates .
Q = m x C x (T0 Tt) it = r x V x C x iT it = 1 x 20 x 4.2 x 103 x 12 900 = 1120 [J/s] 1120 [W] Q = m x C x (T0 Tt) it x 860 = c x V x 60 x C x iT it x 860 Cooling capacity = Considering a safety factor of 20%, 1120 [W] x 1.2 = 1344 [W] = 1 x 20 x 60 x 1.0 x 103 x 12 Thermo-chiller Q x t: Heat capacity [kJ] 15 x 860 1120 [W] 20C Water bath Cooling capacity = Considering a safety factor
IDF120D to IDF240D Construction Principle (Air/Refrigerant Circuit) w Air cooler q Air re-heater Compressed air inlet High temperature humid air from the air compressor passes through the air re-heater q and is pre-cooled by dehumified cool air. Then it is cooled to the specified temperature by the air cooler w using the evaporation heat of refrigerant.
0 q ! !2 o u i !8 !6 !5 SlA Installation !3 !1 VlA 1(P) 2(A) 1(P) 2(A) Warning 1 When exhaust piping is connected to 3(R) port,effective area should be larger than the specified value mentioned in the table below. If it is smaller, air leakage will occur due to back pressure. y q w !4 SlA !7 !4 3(R) VlA !
Q = D __ 4 6 _ 1000 Q = (D d) __ 4 6 _ 1000 Formula (1) .
IN OUT t e q r IN OUT w r w AR30(K)-B/AR40(K)-B q t AR50(K)-B/AR60(K)-B e IN OUT q t r w e IN OUT r w Component Parts No.
VS3135 A01-01 A01-02 A07-52 q Description Electrical entry VS3145 Solenoid cover Body 100 VAC 200 VAC Grommet A12-01 A12-02 A08-52 w e Spool/Sleeve 24 VDC A01-01-63 A01-02-63 A07-52-63 100 VAC 200 VAC Conduit terminal 24 VDC A12-01-63 A12-02-63 A08-52-63 Replacement Parts Material Part no. VS3135 XT019-6 XT013-13-2 XT010-15 Description VS3145 No.
Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the
Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the
How to find the flow rate for water Formula based on Cv factor Q = 14.2 Cv 10.2 P l/min Formula based on effective area (Smm) Q = 0.8 S 10.2 P l/min Q: Flow rate (l/min), P: Pressure differential (P1P2), P1: Upstream pressure (MPa) P2: Downstream pressure (MPa), S: Effective area (mm), Cv: Cv factor 17 Compact Direct Operated Series VDW 2/3 Port Solenoid Valve for Water and Air Safety
VQ1000-FPG-C4M5-D: 6 sets Double check block 757 S0700 Series Construction Body Ported Construction 2(B) (A)4 S0716 2-Position Single r u e w q 3(R2) (R1)5 1 (P) t y i 2-Position Double S0726 2(B) (A)4 r u e w q 3(R2) (R1)5 1 (P) t y i 3-Position Closed Center S0736 r u e w q 2(B) (A)4 (R1)5 1 (P) 3(R2) t y i 4-Position Dual 3-Port Valve S07A6 r u e w q 2(B) 4(A) 5(R1) 3(R2) 1(P) N.C. + N.C
How to find the flow rate for water Formula based on Cv factor Q = 14.2 Cv 10.2 P l/min Formula based on effective area (Smm) Q = 0.8 S 10.2 P l/min Q: Flow rate (l/min), P: Pressure differential (P1P2), P1: Upstream pressure (MPa) P2: Downstream pressure (MPa), S: Effective area (mm), Cv: Cv factor 17
w e q w VQC1100 VQC1101 2(B) (A)4 2(B) (A)4 r r (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) e q w e w q VQC1201 VQC1200 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) r r e q w e q w VQC1300 VQC1400 VQC1301 VQC1401 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) VQC1500 VQC1501 r r 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5
-02-08 VM-30CR VFM350-02-30R Push button (Mushroom) Black Green Yellow VM-30CB VFM350-02-30B VM-30CG VFM350-02-30G VM-30CY VFM350-02-30Y Red VM-32CR VFM350-02-32R Manual operation Push button (Extended) Black Green Yellow VM-32CB VFM350-02-32B VM-32CG VFM350-02-32G VM-32CY VFM350-02-32Y With a set of red, black, green, yellow VM-33C VFM350-02-33 Push button (Flush) Red VM-34CR VFM350-02-34R