Do not use in an environment where there is excessive impact shock. The structure of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated.
B Z + Stroke DB DX DD 90 B 4DT A DS DH 4DR DB DU DO DO DC DE DU DL Rotation (mm) No.
Do not drop or bump. Do not drop, bump or apply excessive impacts (300m/s or more for reed switches and 1000m/s or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires.
DO DS Without air cushion (mm) B Bore size (mm) No.
NT-02 NT-03 NT-04 26 30 25.5 M20 x 1.5 8 13 15.0 12.5 M8 x 1.25 5 32 37 31.5 M26 x 1.5 8 17 19.6 16.5 6 M10 x 1.25 41 47.3 40.5 M32 x 2.0 10 22 25.4 21.0 8 M14 x 1.5 Trunnion Nut Material: Carbon steel (mm) C D d H B Applicable bore size (mm) 20 25, 32 40 Part no.
NT-02 NT-03 NT-04 26 30 25.5 M20 x 1.5 8 13 15.0 12.5 M8 x 1.25 5 32 37 31.5 M26 x 1.5 8 17 19.6 16.5 6 M10 x 1.25 41 47.3 40.5 M32 x 2.0 10 22 25.4 21.0 8 M14 x 1.5 Trunnion Nut Material: Carbon steel (mm) C D d H B Applicable bore size (mm) 20 25, 32 40 Part no.
Do not operate multiple cylinders in synchronization. Avoid applications in which two or more end lock cylinders are synchronized to move one workpiece, as one of the cylinder locks may not be able to release when required. 2. Manual release (Lock type) While pushing the M/O knob, turn it 90 counterclockwise.
Do not make any upward angles in drain line.
Do not allow the weight of piping to be applied directly to the air dryer. HA AT ID Avoid installation on moving objects like trucks, ships, and so forth. Drain Tube AMG Caution AFF A polyurethane tube of 10mm outer diameter is provided as the drain tube for IDFS6E to 11E and IDUS3E to 6E. Use this tube to discharge drainage. Do not use the drain tube in an upward direction.
(Do not tighten with pliers.) @silrc I SERIES NCDJ2 Connection examples to relay and solenoid valve Basic wiring 3 wire system (When power source for switch and load is common) Rd lead wi: Connect io the power sourc e (powet source lerminal) lo operare main circuit of switch.
Note 2) Do not release the OUT side piping port of the product directly to the atmosphere without connecting piping. If the product is used with the piping port released to atmosphere, accuracy may vary.
Do not drop or bump. Do not drop, bump or apply excessive impact (1,000 m/s2) when handling. Even if the switch body is not damaged, the switch may suffer internal damage that will lead to malfunction. 2. Hold the product from the body side when handling. The tensile strength of the power cord is 49 N, and pulling it with a greater force can cause failure. 3.
(Do not tighten with pliers.) I @silrc SERIES NCDJ2 Connection examples to relay and solenoid valve Basic wiring 3 wire system (When power source for switch and load is common) Rd lead wi: Connect io the power sourc e (powet source lerminal) lo operare main circuit of switch.
Cassette base DIN r. ) No,eJ n case of DC cny DLN ra L 1t .gs are alacred DIN rail length DoLrbre wing specilcal,on SDge doube and 3 posrton soleno d va vcs ca. 0e used on a manrfold slatons Nole 2) Speclied layoul Indrate w r ng spec fcal ons on a man Io d specJ.at on sheel Nole thal do!
Do not drop or bump. Do not drop, bump or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.
Do not drop or bump. Do not drop, bump or apply excessive impacts (300m/s2or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.
Do not operate beyond the rated voltage range. If applying voltage over the rated voltage range, equipment may be damaged. 2. Avoid incorrect wiring such as polarity of power supply. Otherwise, equipment may be damaged. 3. Do not short circuit the load. (Do not connect to power supply.) Otherwise, equipment may be damaged.
Ready RD CN3-13 DO-1 PD07 0005 Electromagnetic brake interlock MBR CN3-13 DO-1 PD07 0005 0002 In-position (Positioning completed) INP CN3-9 DO-1 PD08 0004 In-position (Positioning completed) INP CN3-9 DO-1 PD08 0004 Trouble ALM CN3-15 DO-1 PD09 0003 Trouble ALM CN3-15 DO-1 PD09 0003 0 2 -31- (2) Symbol allocation using the setup software: Changing pins CN1-13 to Ready (RD).
Do not apply excessive lateral load to the piston rod.
Do not rotate the cover. If a cover is rotated when installing a cylinder or screwing a fitting into the port, it is likely to damage the junction part with cover. 2.Do not operate with the cushion needle in a fully closed condition. Using it in the fully closed state will cause the cushion seal to be damaged.