<br>The part number of the conversion cable for connecting a teaching box (LEC-T1), etc., to this round connector is “P5062-5.”<br>This conversion cable is a dedicated cable; do not use other commercially available products.<br>Note 1) Controller setting kit: A conversion cable (P5062-5) is not required for the JXC-W2.
<br>Use the special order part number suffix “-X1” when ordering.<br>For details, contact your local SMC sales office or distributor.<br><br>
<br>If the VJ series valves were changed to SYJ series valves during ZR maintenance (standard), they are interchangeable with current SYJ series valves.<br>In this case, however, be sure to replace the gaskets supplied with the valves as well.<br>Note) In old ZR series vacuum systems, there was 1 pilot valve gasket (dedicated for the ZR series) per every 3 solenoid valves.
<br>When this high-speed air flows into the diffuser, the surrounding air between the nozzle and the diffuser is sucked in, and vacuum is generated on the vacuum port side.<br>A video explaining ejector principles can be found here.<br><br>
<br>The ring of the S type is brown, and the ring of the L type is black.<br>However, for the old type, the ring of the S type is silver and the ring of the L type is black.<br><br>In addition, there is either an “S” or an “L” molded into the diffuser part.
<br>Therefore, determine when to replace the vacuum pad by comparing its current state to its state before it was used.<br>Note) The pad connection may become loose depending on the operating conditions and environment. Be sure to perform regular maintenance.
<br>At this time, an amount of air corresponding to the fixed orifice size is sucked in. When in contact with a workpiece, the valve opens and vacuum is generated.<br>In this way, this function restricts the reduction of vacuum pressure when some of the multiple pads are not in use.<br><br>
<br>The following older catalogs are available: IDF1D/2D, IDF/IDU3D to 8D, IDF/IDU11C to 75C, IDF120D to 240D, and IDF370B.<br>For even older models, dial SMC’s toll-free number or call your local SMC sales office. <br><br>“Discontinued Products” section
<br>For the IDG30□: IDG-EL30A<br>For the IDG50□: IDG-EL50A<br><br>For the IDG60L/S, IDG75L/S, and IDG100L/S: Replace the product as a whole with the new type.
<br>When the red part of the indicator reaches the top of the display, the differential pressure is approximately 0.1 MPa. <br>The element service indicator is not a consumable item and does not need to be replaced. <br>Once you replace the element, and it is no longer clogged, the red part of the indicator will go down again.
<br>Note 2) For the large free standing type (the AFF75A and larger and the AMD800 and larger), replace the element when the pressure drop reaches 0.1 MPa or after 1 year of use, whichever comes first.<br><br>
<br>※ You can also find the element part numbers in the “Replacement Parts” table in the “Construction” section in the catalog of each series. <br>Note) Before replacing the element, make sure that the residual pressure in the filter bowl is at “0.”<br><br>
<br>Note) For the normally open (N.O.) auto drain type, the discharge valve will not close if the pressure in the case is more than 0.1 MPa. <br>In this case, check for pressure drops or flow rate drops on the supply side. <br>Refer to the catalog for case assembly models. <br>The AM□ and AFF series catalogs can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=air-preparation-filters&fa_id=10898
<br>This amount should not exceed 4.4 L/min (ANR) for IR1000/2000 series regulators and 11.5 L/min (ANR) for IR3000 series regulators. <br>For new IR1000-A/2000-A/3000-A series regulators, 1 L/min (ANR) is the max. amount. <br>Check to confirm whether the leakage is actually bleed air before taking any further steps.
<br>IR1000-A, IR2000-A, and IR3000-A series precision regulators as well as IR1200-A, IR2200-A, and IR3200-A series regulators were released in August 2014. <br><br>
<br>The type with 4 points can output up to 4 preset pressures by combining the ON/OFF settings of the 2 input signals of the switch. <br>The type with 16 points can output up to 16 points by combining the ON/OFF settings of the 4 input signals of the switch. <br>It is recommended that the pressure be set to 0 MPa for one of the preset pressures for safety reasons.
<br>You cannot change the pressure units or the number of digits.<br>The pressure display unit is indicated by the part number when ordering the product.<br>The MPa type displays up to 3 decimal places (.000).<br>For example, if the pressure is 0.120 MPa, it is displayed as “.120”. Note) Old ITV series regulators display only up to 2 decimal places (.00).
<br>The pressure gauge adapter assembly and round type pressure gauge can be mounted with the square embedded type pressure gauge removed.<br>Replace the inside O-ring with a new one.<br>If the O-ring is not replaced at this time, air will leak.
<br>The bracket and set nut (for securing the bracket) can be purchased and can be retrofitted to an AR series regulator if ordered with the following assembly part numbers.<br>It is also possible to order only the set nut.<br><br>