Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: Centralized Lead Wired, w/Bracket, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side, With regulator
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: L1 (w/Control Unit, Supply Port: Left
Function: 2 Position Single, Body Style: Body Ported/Individual Pilot EXH, Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 110~120VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: None, Manual Override: Locking Slotted Style, Piping: Side, Port Size: Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1, Thread: NPTF, Option: Foot Bracket
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Function: 1 (2 Position Single), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: B (Locking Slotted Style), Piping: Side, Port Size: 02 (Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1), Thread: T (NPTF), Option
Rated Distance Range: 0.01 to 0.03mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: Centralized Lead Wired, w/Bracket, Bracket Option: Bracket, Control Unit: w/Control Unit,
Rated Distance Range: 0.01 to 0.03mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: NPN Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: Centralized Lead Wired, w/Bracket, Bracket Option: Bracket, Control Unit: w/Control Unit,
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: Centralized Lead Wired, w/Bracket, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Right Side, With regulator, Square type pressure gauge; 0.2 MPa, 2 Port Solenoid
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: Centralized Lead Wired, w/Bracket, Bracket Option: Bracket, Control Unit: w/Control Unit,
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: Centralized Lead Wired, w/Bracket, Bracket Option: Bracket, Control Unit: w/Control Unit,
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: Centralized Lead Wired, w/Bracket, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side, With regulator, Square type pressure gauge; 0.4 MPa, 2 Port Solenoid
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: Centralized Lead Wired, w/Bracket, Bracket Option: Bracket, Control Unit: w/Control Unit,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Control unit: With control unit (supply port: left side), Number of stations: Triple, Option: With Bracket, Voltage(V): 24 DC, Detection distance(mm): 0.02 to 0.15, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: NPN 1 output, Unit specification for pressure values: With unit switching function, Regulator: Round type pressure gauge with regulator
Control unit: With control unit (supply port: left side), Number of stations: Triple, Option: With Bracket, Voltage(V): 24 DC, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Regulator: Round type pressure gauge with regulator (
Function: 2 Position Single, Body Style: Body Ported/Individual Pilot EXH, Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 110~120VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: None, Manual Override: Locking Slotted Style, Piping: Side, Port Size: Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1, Option: Foot Bracket
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: B (PNP, 2 Outputs), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
"VALVE, 4/5 PORT SOLENOID VALVE